FCC ID GX9POVSZB

Occupancy/Vacancy Sensors

by Climax Technology Co Ltd

Grantee Code: GX9   Product Code: POVSZB
Latest application date: 2021-04-28

FCC ID Device Details

FCC IDGX9POVSZB
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeGX9
Product CodePOVSZB
Applicant BusinessClimax Technology Co Ltd 🇹🇼
Related Domains climax.com.tw
Equipment ClassOccupancy/Vacancy Sensors
Test FirmWorldwide Testing Services (Taiwan) Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2475 MHzOriginal Equipment2021-04-28

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2021-04-28PDF 376.4 KB
Internal PhotosInternal Photos2021-04-28PDF 823.3 KB
External PhotosExternal Photos2021-04-28PDF 578.5 KB
ID Label and LocationID Label/Location Info2021-04-28PDF 76.1 KB
Test Setup PhotosTest Setup Photos2021-04-28PDF 612.7 KB
Test ReportTest Report2021-04-28PDF 705.4 KB
Authorization LetterCover Letter(s)2021-04-28PDF 26.8 KB
Confidentiality RequestCover Letter(s)2021-04-28PDF 29 KB
Manufacturer DeclarationCover Letter(s)2021-04-28PDF 29.2 KB
RF Exposure InfoRF Exposure Info2021-04-28PDF 195.5 KB
Block Diagram Metadata onlyBlock DiagramPDF 319.3 KB
Schematics Metadata onlySchematicsPDF 547.3 KB
Operational Description Metadata onlyOperational DescriptionPDF 9.6 KB
Antenna Spec Metadata onlyParts List/Tune Up InfoPDF 51 KB

Application Information

Application IDAqKrYZzYvP8wxc963hsByQ==
Final Action Date2021-04-28
Application PurposeOriginal Equipment
Applicant FRN0021168695
ModelPOVSZB
Frequency Range2402-2475 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionOccupancy/Vacancy Sensors
Responsible PartyGeorge Lin, Hardware Engineer, george@climax.com.tw , 886-2-2794-0001
Technical ContactDanny Sung, Worldwide Testing Services (Taiwan) Co., Ltd., danny@wts-lab.com , +886266068877
Test FirmDanny Sung, Worldwide Testing Services (Taiwan) Co., Ltd., danny@wts-lab.com , 886-2-6606-8877
TCB EmailJoergKusig@eurofins.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
AqKrYZzYvP8wxc963hsByQ==2021-04-28Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2475 MHz0.004800015C

Grants

TCB Grant - Application AqKrYZzYvP8wxc963hsByQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 04/28/2021

Application Dated: 04/28/2021
Climax Technology Co Ltd
No. 258, Sinhu 2nd Rd., Neihu District
Taipei City, 114
Taiwan
 
Attention: George Lin , Hardware Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  GX9POVSZB
Name of Grantee:  Climax Technology Co Ltd
Equipment Class: Digital Transmission System
Notes: Occupancy/Vacancy Sensors
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2475.0 0.0048  

Output power listed is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application AqKrYZzYvP8wxc963hsByQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Climax Technology Co Ltd
No. 258, Sinhu 2nd Rd., Neihu District
Taipei City, 114
Taiwan
  Date of Grant: 04/28/2021

Application Dated: 04/28/2021
 
Attention: George Lin , Hardware Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  GX9POVSZB
Name of Grantee:  Climax Technology Co Ltd
Equipment Class: Digital Transmission System
Notes: Occupancy/Vacancy Sensors
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2475.0 0.0048  

Output power listed is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.



Mail To: