FCC ID H25PD2TX100S

COFDM Video Transmitter

by DTC Communications Inc.

Grantee Code: H25   Product Code: PD2TX100S
Latest application date: 2009-03-30

FCC ID Device Details

FCC IDH25PD2TX100S
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeH25
Product CodePD2TX100S
Applicant BusinessDTC Communications Inc. 🇺🇸
Related Domains dtccom.com
Equipment ClassCOFDM Video Transmitter

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2451-2482.5 MHzOriginal Equipment2009-03-30

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2009-03-30PDF 1.8 MB
Internal photosInternal Photos2009-03-30PDF 227 KB
External photosExternal Photos2009-03-30PDF 83.6 KB
FCC ID labelID Label/Location Info2009-03-30PDF 42.3 KB
Test report 1Test Report2009-03-30PDF 4.4 MB
Test report 2Test Report2009-03-30PDF 183.6 KB
ATCB commentsCover Letter(s)2009-03-30PDF 58.4 KB
Cover letterCover Letter(s)2009-03-30PDF 24.3 KB
Request for confidentialityCover Letter(s)2009-03-30PDF 14.1 KB
Response to ATCBCover Letter(s)2009-03-30PDF 5.6 KB
SARRF Exposure Info2009-03-30PDF 3.8 MB

Application Information

Application IDQbX4r390io9cBNv5m+LEpQ==
Final Action Date2009-03-30
Application PurposeOriginal Equipment
Applicant FRN0004302550
ModelPD2TX100S
Frequency Range2451-2482.5 MHz
Equipment ClassTNT - Licensed Non-Broadcast Transmitter Worn on Body
Device DescriptionCOFDM Video Transmitter
Responsible PartyJoe L. Desjardins, Dir., New Product Development, joe.desjardins@dtccom.com , 603 880-4411
TCB Emailhotline@americantcb.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. SAR for body worn operation has been tested and meets the FCC Uncontrolled Exposure/General Population RF exposure guidelines when used with the listed accessories designated for this product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This device may operate only with antennas as described in this filing. Tuning procedures must not exceed the lower and upper frequency limits specified on this grant. SAR was evaluated for body worn operating modes. Maximum SAR values reported are: Body 0.08 w/kg.

Applications

Application IDDatePurpose
QbX4r390io9cBNv5m+LEpQ==2009-03-30Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
2451-2482.5 MHz0.112ppm1M25W7D9
2451.5-2482 MHz0.112ppm2M35W7D9
2452.9-2480.5 MHz0.112ppm5M80W7D9
2453.35-2480.15 MHz0.112ppm6M70W7D9
2454-2479.5 MHz0.112ppm7M55W7D9

Grants

TCB Grant - Application QbX4r390io9cBNv5m+LEpQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 03/30/2009

Application Dated: 03/29/2009
DTC Communications Inc.
486 Amherst Street
Nashua, NH 03063
 
Attention: Joe Desjardins , Dir., New Product Development

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  H25PD2TX100S
Name of Grantee:  DTC Communications Inc.
Equipment Class: Licensed Non-Broadcast Transmitter Worn on Body
Notes: COFDM Video Transmitter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 2451.0  -  2482.5 0.11 2.0  PM 1M25W7D
90 2454.0  -  2479.5 0.11 2.0  PM 7M55W7D
90 2451.5  -  2482.0 0.11 2.0  PM 2M35W7D
90 2452.9  -  2480.5 0.11 2.0  PM 5M80W7D
90 2453.35  -  2480.15 0.11 2.0  PM 6M70W7D

Output power listed is conducted. SAR for body worn operation has been tested and meets the FCC Uncontrolled Exposure/General Population RF exposure guidelines when used with the listed accessories designated for this product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This device may operate only with antennas as described in this filing. Tuning procedures must not exceed the lower and upper frequency limits specified on this grant. SAR was evaluated for body worn operating modes. Maximum SAR values reported are: Body 0.08 w/kg.

EAS Grant - Application QbX4r390io9cBNv5m+LEpQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

DTC Communications Inc.
486 Amherst Street
Nashua, NH 03063
United States
  Date of Grant: 03/30/2009

Application Dated: 03/29/2009
 
Attention: Joe Desjardins , Dir., New Product Development

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  H25PD2TX100S
Name of Grantee:  DTC Communications Inc.
Equipment Class: Licensed Non-Broadcast Transmitter Worn on Body
Notes: COFDM Video Transmitter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 2451.0  -  2482.5 0.11 2.0  PM 1M25W7D
90 2454.0  -  2479.5 0.11 2.0  PM 7M55W7D
90 2451.5  -  2482.0 0.11 2.0  PM 2M35W7D
90 2452.9  -  2480.5 0.11 2.0  PM 5M80W7D
90 2453.35  -  2480.15 0.11 2.0  PM 6M70W7D

Output power listed is conducted. SAR for body worn operation has been tested and meets the FCC Uncontrolled Exposure/General Population RF exposure guidelines when used with the listed accessories designated for this product. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This device may operate only with antennas as described in this filing. Tuning procedures must not exceed the lower and upper frequency limits specified on this grant. SAR was evaluated for body worn operating modes. Maximum SAR values reported are: Body 0.08 w/kg.