FCC ID H4JAMP-4-150
30W VHF Amplifier
by Codan Radio Communications
Grantee Code: H4J Product Code: AMP4150
Latest application date: 2021-04-20
FCC ID Device Details
| FCC ID | H4JAMP-4-150 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | H4J |
| Product Code | AMP4150 |
| Applicant Business | Codan Radio Communications 🇨🇦 |
| Related Domains | |
| Equipment Class | 30W VHF Amplifier |
| Test Firm | Timco Engineering, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 150.8-152.855 MHz | Class II permissive change or modification of presently authorized equipment | 2021-04-20 |
| 136-174 MHz | Class II permissive change or modification of presently authorized equipment | 2012-05-17 |
| 136-174 MHz | Original Equipment | 2011-12-15 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2011-12-15 | PDF 167.1 KB |
| Internal Photos | Internal Photos | 2021-04-20 | PDF 674.3 KB |
| Internal Photos | Internal Photos | 2011-12-15 | PDF 1.2 MB |
| External Photos | External Photos | 2011-12-15 | PDF 359.1 KB |
| Label Info | ID Label/Location Info | 2011-12-15 | PDF 30.4 KB |
| Test Setup Photos | Test Setup Photos | 2011-12-15 | PDF 513 KB |
| TR PT90 3 | Test Report | 2021-04-20 | PDF 531.2 KB |
| Test Report | Test Report | 2012-05-17 | PDF 282.7 KB |
| Test Report | Test Report | 2011-12-15 | PDF 269.6 KB |
| CIIPC Cover Letter | Cover Letter(s) | 2021-04-20 | PDF 208.4 KB |
| Confidentiality Request | Cover Letter(s) | 2021-04-20 | PDF 245.1 KB |
| POA Letter | Cover Letter(s) | 2021-04-20 | PDF 250.1 KB |
| Class II Cover Letter | Cover Letter(s) | 2012-05-17 | PDF 120 KB |
| Confidential Letter | Cover Letter(s) | 2011-12-15 | PDF 142.4 KB |
| Justification Letter | Cover Letter(s) | 2011-12-15 | PDF 171.2 KB |
| RF Exposure | RF Exposure Info | 2011-12-15 | PDF 140.1 KB |
| Block Diagram Metadata only | Block Diagram | PDF 227.4 KB | |
| Schematics Metadata only | Schematics | PDF 508.3 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 323.1 KB | |
| Tuning Procedure Metadata only | Parts List/Tune Up Info | PDF 410.6 KB |
Application Information
| Application ID | +vA3dA1esmBEE9EqwkHoDQ== |
|---|---|
| Final Action Date | 2021-04-20 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0009439571 |
| Model | AMP-4-150 |
| Frequency Range | 150.8-152.855 MHz |
| Equipment Class | AMP - Amplifier |
| Device Description | 30W VHF Amplifier |
| Responsible Party | Nathan Wren, Engineering Operations Manager, nathan.wren@codancomms.com |
| Test Firm | Bruno Clavier, Timco Engineering, Inc., bruno@timcoengr.com |
| TCB Email | tei@timcoengr.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class II change: April 15th, 2021 to replace the primary gain stage transistor with a comparable components that is more robust against electrostatic discharge. Note 1: F1D, F1E, F3D, F3E, G3E, G2B |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| +vA3dA1esmBEE9EqwkHoDQ== | 2021-04-20 | Class II permissive change or modification of presently authorized equipment |
| tUby+MVieLtwLLblXlAnmQ== | 2012-05-17 | Class II permissive change or modification of presently authorized equipment |
| eKcfZmoKLCKuGKDmZuQ/eA== | 2011-12-15 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 136-174 MHz | 30.0000000 | NOTE 1 | 22, 80, 90 | ||
| 136-174 MHz | 30.0000000 | NOTE 1 | 22, 80, 90 | BP | |
| 152.855-154 MHz | 30 | Amp | F3E | 9 | BP |
| 152.855-154 MHz | 30 | Amp | G3E | 9 | BP |
| 152.855-154 MHz | 30 | Amp | G2B | 9 | BP |
| 152.855-154 MHz | 30 | Amp | F1D | 9 | BP |
| 152.855-154 MHz | 30 | Amp | F1E | 9 | BP |
| 152.855-154 MHz | 30 | Amp | F3D | 9 | BP |
| 154-156.248 MHz | 30 | Amp | F1D | 80, 9 | BP |
| 154-156.248 MHz | 30 | Amp | F1E | 80, 9 | BP |
| 154-156.248 MHz | 30 | Amp | F3D | 80, 9 | BP |
| 154-156.248 MHz | 30 | Amp | F3E | 80, 9 | BP |
| 154-156.248 MHz | 30 | Amp | G3E | 80, 9 | BP |
| 154-156.248 MHz | 30 | Amp | G2B | 80, 9 | BP |
| 156.248-157.188 MHz | 30 | Amp | F1D | 8 | BP |
| 156.248-157.188 MHz | 30 | Amp | F1E | 8 | BP |
| 156.248-157.188 MHz | 30 | Amp | F3D | 8 | BP |
| 156.248-157.188 MHz | 30 | Amp | F3E | 8 | BP |
| 156.248-157.188 MHz | 30 | Amp | G3E | 8 | BP |
| 156.248-157.188 MHz | 30 | Amp | G2B | 8 | BP |
| 157.188-157.45 MHz | 30 | Amp | F1D | 80, 9 | BP |
| 157.188-157.45 MHz | 30 | Amp | F1E | 80, 9 | BP |
| 157.188-157.45 MHz | 30 | Amp | F3D | 80, 9 | BP |
| 157.188-157.45 MHz | 30 | Amp | F3E | 80, 9 | BP |
| 157.188-157.45 MHz | 30 | Amp | G3E | 80, 9 | BP |
| 157.188-157.45 MHz | 30 | Amp | G2B | 80, 9 | BP |
| 157.45-161.575 MHz | 30 | Amp | F1D | 22, 80, 9 | BP |
| 157.45-161.575 MHz | 30 | Amp | F1E | 22, 80, 9 | BP |
| 157.45-161.575 MHz | 30 | Amp | F3D | 22, 80, 9 | BP |
| 157.45-161.575 MHz | 30 | Amp | F3E | 22, 80, 9 | BP |
| 157.45-161.575 MHz | 30 | Amp | G3E | 22, 80, 9 | BP |
| 157.45-161.575 MHz | 30 | Amp | G2B | 22, 80, 9 | BP |
| 161.575-161.625 MHz | 30 | Amp | F1D | 22, 8 | BP |
| 161.575-161.625 MHz | 30 | Amp | F1E | 22, 8 | BP |
| 161.575-161.625 MHz | 30 | Amp | F3D | 22, 8 | BP |
| 161.575-161.625 MHz | 30 | Amp | F3E | 22, 8 | BP |
| 161.575-161.625 MHz | 30 | Amp | G3E | 22, 8 | BP |
| 161.575-161.625 MHz | 30 | Amp | G2B | 22, 8 | BP |
| 161.625-161.775 MHz | 30 | Amp | F1D | 22 | BP |
| 161.625-161.775 MHz | 30 | Amp | F1E | 22 | BP |
| 161.625-161.775 MHz | 30 | Amp | F3D | 22 | BP |
| 161.625-161.775 MHz | 30 | Amp | F3E | 22 | BP |
| 161.625-161.775 MHz | 30 | Amp | G3E | 22 | BP |
| 161.625-161.775 MHz | 30 | Amp | G2B | 22 | BP |
| 161.775-161.963 MHz | 30 | Amp | F1D | 80, 9 | BP |
| 161.775-161.963 MHz | 30 | Amp | F1E | 80, 9 | BP |
| 161.775-161.963 MHz | 30 | Amp | F3D | 80, 9 | BP |
| 161.775-161.963 MHz | 30 | Amp | F3E | 80, 9 | BP |
| 161.775-161.963 MHz | 30 | Amp | G3E | 80, 9 | BP |
| 161.775-161.963 MHz | 30 | Amp | G2B | 80, 9 | BP |
| 161.963-162.038 MHz | 30 | Amp | F1D | 8 | BP |
| 161.963-162.038 MHz | 30 | Amp | F1E | 8 | BP |
| 161.963-162.038 MHz | 30 | Amp | F3D | 8 | BP |
| 161.963-162.038 MHz | 30 | Amp | F3E | 8 | BP |
| 161.963-162.038 MHz | 30 | Amp | G3E | 8 | BP |
| 161.963-162.038 MHz | 30 | Amp | G2B | 8 | BP |
| 162.038-174 MHz | 30 | Amp | F1D | 9 | BP |
| 162.038-174 MHz | 30 | Amp | F1E | 9 | BP |
| 162.038-174 MHz | 30 | Amp | F3D | 9 | BP |
| 162.038-174 MHz | 30 | Amp | F3E | 9 | BP |
| 162.038-174 MHz | 30 | Amp | G3E | 9 | BP |
| 162.038-174 MHz | 30 | Amp | G2B | 9 | BP |
Grants
TCB Grant - Application tUby+MVieLtwLLblXlAnmQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 <BR>P.O. Box 370, Newberry, FL 32669 |
Date of Grant: 05/17/2012 Application Dated: 05/17/2012 |
| Codan Radio Communications |
| 43 Erie Street |
| Victoria, BC, V8V 1P8 Canada |
| Attention: Michael Cyr , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | H4JAMP-4-150 |
| Name of Grantee: | Codan Radio Communications |
| Equipment Class: | Amplifier |
| Notes: | 30W VHF POWER AMPLIFIER |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BP | 22, 80, 90 | 136.0 - 174.0 | 30.0 | NOTE 1 |
| Class II change: April 17th, 2012 to add emission designator G2B and grant note BP. Note 1: F1D, F1E, F3D, F3E, G3E, G2B |
| BP: | The output power is continuously variable from the value listed in this entry to 65%-70% of the value listed. |
EAS Grant - Application tUby+MVieLtwLLblXlAnmQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Codan Radio Communications 43 Erie Street Victoria, BC, V8V 1P8 Canada |
Date of Grant: 05/17/2012 Application Dated: 05/17/2012 |
| Attention: Michael Cyr , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | H4JAMP-4-150 |
| Name of Grantee: | Codan Radio Communications |
| Equipment Class: | Amplifier |
| Notes: | 30W VHF POWER AMPLIFIER |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BP | 22, 80, 90 | 136.0 - 174.0 | 30.0 | NOTE 1 |
| Class II change: April 17th, 2012 to add emission designator G2B and grant note BP. Note 1: F1D, F1E, F3D, F3E, G3E, G2B |
| BP: | The output power is continuously variable from the value listed in this entry to 65%-70% of the value listed. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 <BR>P.O. Box 370, Newberry, FL 32669 |
Date of Grant: 12/15/2011 Application Dated: 12/15/2011 |
| Codan Radio Communications |
| 43 Erie Street |
| Victoria, BC, V8V 1P8 Canada |
| Attention: Michael Cyr , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | H4JAMP-4-150 |
| Name of Grantee: | Codan Radio Communications |
| Equipment Class: | Amplifier |
| Notes: | 30W VHF POWER AMPLIFIER |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22, 80, 90 | 136.0 - 174.0 | 30.0 | NOTE 1 |
| NOTE: F1D, F1E, F3D, F3E, G3E |
EAS Grant - Application eKcfZmoKLCKuGKDmZuQ/eA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Codan Radio Communications 43 Erie Street Victoria, BC, V8V 1P8 Canada |
Date of Grant: 12/15/2011 Application Dated: 12/15/2011 |
| Attention: Michael Cyr , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | H4JAMP-4-150 |
| Name of Grantee: | Codan Radio Communications |
| Equipment Class: | Amplifier |
| Notes: | 30W VHF POWER AMPLIFIER |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22, 80, 90 | 136.0 - 174.0 | 30.0 | NOTE 1 |
| NOTE: F1D, F1E, F3D, F3E, G3E |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 04/20/2021 Application Dated: 04/20/2021 |
| Codan Radio Communications |
| 43 Erie Street |
| Victoria, BC, V8V 1P8 Canada |
| Attention: Nathan Wren , Engineering Operations Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | H4JAMP-4-150 |
| Name of Grantee: | Codan Radio Communications |
| Equipment Class: | Amplifier |
| Notes: | 30W VHF Amplifier |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BP | 22, 90 | 150.8 - 152.855 | 30.0 | Amp | F1D |
| BP | 22, 90 | 150.8 - 152.855 | 30.0 | Amp | F1E |
| BP | 22, 90 | 150.8 - 152.855 | 30.0 | Amp | F3D |
| BP | 22, 90 | 150.8 - 152.855 | 30.0 | Amp | F3E |
| BP | 22, 90 | 150.8 - 152.855 | 30.0 | Amp | G3E |
| BP | 22, 90 | 150.8 - 152.855 | 30.0 | Amp | G2B |
| BP | 90 | 152.855 - 154.0 | 30.0 | Amp | F1D |
| BP | 90 | 152.855 - 154.0 | 30.0 | Amp | F1E |
| BP | 90 | 152.855 - 154.0 | 30.0 | Amp | F3D |
| BP | 90 | 152.855 - 154.0 | 30.0 | Amp | F3E |
| BP | 90 | 152.855 - 154.0 | 30.0 | Amp | G3E |
| BP | 90 | 152.855 - 154.0 | 30.0 | Amp | G2B |
| BP | 80, 90 | 154.0 - 156.2475 | 30.0 | Amp | F1D |
| BP | 80, 90 | 154.0 - 156.2475 | 30.0 | Amp | F1E |
| BP | 80, 90 | 154.0 - 156.2475 | 30.0 | Amp | F3D |
| BP | 80, 90 | 154.0 - 156.2475 | 30.0 | Amp | F3E |
| BP | 80, 90 | 154.0 - 156.2475 | 30.0 | Amp | G3E |
| BP | 80, 90 | 154.0 - 156.2475 | 30.0 | Amp | G2B |
| BP | 80 | 156.2475 - 157.1875 | 30.0 | Amp | F1D |
| BP | 80 | 156.2475 - 157.1875 | 30.0 | Amp | F1E |
| BP | 80 | 156.2475 - 157.1875 | 30.0 | Amp | F3D |
| BP | 80 | 156.2475 - 157.1875 | 30.0 | Amp | F3E |
| BP | 80 | 156.2475 - 157.1875 | 30.0 | Amp | G3E |
| BP | 80 | 156.2475 - 157.1875 | 30.0 | Amp | G2B |
| BP | 80, 90 | 157.1875 - 157.45 | 30.0 | Amp | F1D |
| BP | 80, 90 | 157.1875 - 157.45 | 30.0 | Amp | F1E |
| BP | 80, 90 | 157.1875 - 157.45 | 30.0 | Amp | F3D |
| BP | 80, 90 | 157.1875 - 157.45 | 30.0 | Amp | F3E |
| BP | 80, 90 | 157.1875 - 157.45 | 30.0 | Amp | G3E |
| BP | 80, 90 | 157.1875 - 157.45 | 30.0 | Amp | G2B |
| BP | 22, 80, 90 | 157.45 - 161.575 | 30.0 | Amp | F1D |
| BP | 22, 80, 90 | 157.45 - 161.575 | 30.0 | Amp | F1E |
| BP | 22, 80, 90 | 157.45 - 161.575 | 30.0 | Amp | F3D |
| BP | 22, 80, 90 | 157.45 - 161.575 | 30.0 | Amp | F3E |
| BP | 22, 80, 90 | 157.45 - 161.575 | 30.0 | Amp | G3E |
| BP | 22, 80, 90 | 157.45 - 161.575 | 30.0 | Amp | G2B |
| BP | 22, 80 | 161.575 - 161.625 | 30.0 | Amp | F1D |
| BP | 22, 80 | 161.575 - 161.625 | 30.0 | Amp | F1E |
| BP | 22, 80 | 161.575 - 161.625 | 30.0 | Amp | F3D |
| BP | 22, 80 | 161.575 - 161.625 | 30.0 | Amp | F3E |
| BP | 22, 80 | 161.575 - 161.625 | 30.0 | Amp | G3E |
| BP | 22, 80 | 161.575 - 161.625 | 30.0 | Amp | G2B |
| BP | 22 | 161.625 - 161.775 | 30.0 | Amp | F1D |
| BP | 22 | 161.625 - 161.775 | 30.0 | Amp | F1E |
| BP | 22 | 161.625 - 161.775 | 30.0 | Amp | F3D |
| BP | 22 | 161.625 - 161.775 | 30.0 | Amp | F3E |
| BP | 22 | 161.625 - 161.775 | 30.0 | Amp | G3E |
| BP | 22 | 161.625 - 161.775 | 30.0 | Amp | G2B |
| BP | 80, 90 | 161.775 - 161.9625 | 30.0 | Amp | F1D |
| BP | 80, 90 | 161.775 - 161.9625 | 30.0 | Amp | F1E |
| BP | 80, 90 | 161.775 - 161.9625 | 30.0 | Amp | F3D |
| BP | 80, 90 | 161.775 - 161.9625 | 30.0 | Amp | F3E |
| BP | 80, 90 | 161.775 - 161.9625 | 30.0 | Amp | G3E |
| BP | 80, 90 | 161.775 - 161.9625 | 30.0 | Amp | G2B |
| BP | 80 | 161.9625 - 162.0375 | 30.0 | Amp | F1D |
| BP | 80 | 161.9625 - 162.0375 | 30.0 | Amp | F1E |
| BP | 80 | 161.9625 - 162.0375 | 30.0 | Amp | F3D |
| BP | 80 | 161.9625 - 162.0375 | 30.0 | Amp | F3E |
| BP | 80 | 161.9625 - 162.0375 | 30.0 | Amp | G3E |
| BP | 80 | 161.9625 - 162.0375 | 30.0 | Amp | G2B |
| BP | 90 | 162.0375 - 174.0 | 30.0 | Amp | F1D |
| BP | 90 | 162.0375 - 174.0 | 30.0 | Amp | F1E |
| BP | 90 | 162.0375 - 174.0 | 30.0 | Amp | F3D |
| BP | 90 | 162.0375 - 174.0 | 30.0 | Amp | F3E |
| BP | 90 | 162.0375 - 174.0 | 30.0 | Amp | G3E |
| BP | 90 | 162.0375 - 174.0 | 30.0 | Amp | G2B |
| Class II change: April 15th, 2021 to replace the primary gain stage transistor with a comparable components that is more robust against electrostatic discharge. Note 1: F1D, F1E, F3D, F3E, G3E, G2B |
| BP: | The output power is continuously variable from the value listed in this entry to 65%-70% of the value listed. |
EAS Grant - Application +vA3dA1esmBEE9EqwkHoDQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Codan Radio Communications 43 Erie Street Victoria, BC, V8V 1P8 Canada |
Date of Grant: 04/20/2021 Application Dated: 04/20/2021 |
| Attention: Nathan Wren , Engineering Operations Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | H4JAMP-4-150 |
| Name of Grantee: | Codan Radio Communications |
| Equipment Class: | Amplifier |
| Notes: | 30W VHF Amplifier |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BP | 22, 90 | 150.8 - 152.855 | 30.0 | Amp | F1D |
| BP | 22, 90 | 150.8 - 152.855 | 30.0 | Amp | F1E |
| BP | 22, 90 | 150.8 - 152.855 | 30.0 | Amp | F3D |
| BP | 22, 90 | 150.8 - 152.855 | 30.0 | Amp | F3E |
| BP | 22, 90 | 150.8 - 152.855 | 30.0 | Amp | G3E |
| BP | 22, 90 | 150.8 - 152.855 | 30.0 | Amp | G2B |
| BP | 90 | 152.855 - 154.0 | 30.0 | Amp | F1D |
| BP | 90 | 152.855 - 154.0 | 30.0 | Amp | F1E |
| BP | 90 | 152.855 - 154.0 | 30.0 | Amp | F3D |
| BP | 90 | 152.855 - 154.0 | 30.0 | Amp | F3E |
| BP | 90 | 152.855 - 154.0 | 30.0 | Amp | G3E |
| BP | 90 | 152.855 - 154.0 | 30.0 | Amp | G2B |
| BP | 80, 90 | 154.0 - 156.2475 | 30.0 | Amp | F1D |
| BP | 80, 90 | 154.0 - 156.2475 | 30.0 | Amp | F1E |
| BP | 80, 90 | 154.0 - 156.2475 | 30.0 | Amp | F3D |
| BP | 80, 90 | 154.0 - 156.2475 | 30.0 | Amp | F3E |
| BP | 80, 90 | 154.0 - 156.2475 | 30.0 | Amp | G3E |
| BP | 80, 90 | 154.0 - 156.2475 | 30.0 | Amp | G2B |
| BP | 80 | 156.2475 - 157.1875 | 30.0 | Amp | F1D |
| BP | 80 | 156.2475 - 157.1875 | 30.0 | Amp | F1E |
| BP | 80 | 156.2475 - 157.1875 | 30.0 | Amp | F3D |
| BP | 80 | 156.2475 - 157.1875 | 30.0 | Amp | F3E |
| BP | 80 | 156.2475 - 157.1875 | 30.0 | Amp | G3E |
| BP | 80 | 156.2475 - 157.1875 | 30.0 | Amp | G2B |
| BP | 80, 90 | 157.1875 - 157.45 | 30.0 | Amp | F1D |
| BP | 80, 90 | 157.1875 - 157.45 | 30.0 | Amp | F1E |
| BP | 80, 90 | 157.1875 - 157.45 | 30.0 | Amp | F3D |
| BP | 80, 90 | 157.1875 - 157.45 | 30.0 | Amp | F3E |
| BP | 80, 90 | 157.1875 - 157.45 | 30.0 | Amp | G3E |
| BP | 80, 90 | 157.1875 - 157.45 | 30.0 | Amp | G2B |
| BP | 22, 80, 90 | 157.45 - 161.575 | 30.0 | Amp | F1D |
| BP | 22, 80, 90 | 157.45 - 161.575 | 30.0 | Amp | F1E |
| BP | 22, 80, 90 | 157.45 - 161.575 | 30.0 | Amp | F3D |
| BP | 22, 80, 90 | 157.45 - 161.575 | 30.0 | Amp | F3E |
| BP | 22, 80, 90 | 157.45 - 161.575 | 30.0 | Amp | G3E |
| BP | 22, 80, 90 | 157.45 - 161.575 | 30.0 | Amp | G2B |
| BP | 22, 80 | 161.575 - 161.625 | 30.0 | Amp | F1D |
| BP | 22, 80 | 161.575 - 161.625 | 30.0 | Amp | F1E |
| BP | 22, 80 | 161.575 - 161.625 | 30.0 | Amp | F3D |
| BP | 22, 80 | 161.575 - 161.625 | 30.0 | Amp | F3E |
| BP | 22, 80 | 161.575 - 161.625 | 30.0 | Amp | G3E |
| BP | 22, 80 | 161.575 - 161.625 | 30.0 | Amp | G2B |
| BP | 22 | 161.625 - 161.775 | 30.0 | Amp | F1D |
| BP | 22 | 161.625 - 161.775 | 30.0 | Amp | F1E |
| BP | 22 | 161.625 - 161.775 | 30.0 | Amp | F3D |
| BP | 22 | 161.625 - 161.775 | 30.0 | Amp | F3E |
| BP | 22 | 161.625 - 161.775 | 30.0 | Amp | G3E |
| BP | 22 | 161.625 - 161.775 | 30.0 | Amp | G2B |
| BP | 80, 90 | 161.775 - 161.9625 | 30.0 | Amp | F1D |
| BP | 80, 90 | 161.775 - 161.9625 | 30.0 | Amp | F1E |
| BP | 80, 90 | 161.775 - 161.9625 | 30.0 | Amp | F3D |
| BP | 80, 90 | 161.775 - 161.9625 | 30.0 | Amp | F3E |
| BP | 80, 90 | 161.775 - 161.9625 | 30.0 | Amp | G3E |
| BP | 80, 90 | 161.775 - 161.9625 | 30.0 | Amp | G2B |
| BP | 80 | 161.9625 - 162.0375 | 30.0 | Amp | F1D |
| BP | 80 | 161.9625 - 162.0375 | 30.0 | Amp | F1E |
| BP | 80 | 161.9625 - 162.0375 | 30.0 | Amp | F3D |
| BP | 80 | 161.9625 - 162.0375 | 30.0 | Amp | F3E |
| BP | 80 | 161.9625 - 162.0375 | 30.0 | Amp | G3E |
| BP | 80 | 161.9625 - 162.0375 | 30.0 | Amp | G2B |
| BP | 90 | 162.0375 - 174.0 | 30.0 | Amp | F1D |
| BP | 90 | 162.0375 - 174.0 | 30.0 | Amp | F1E |
| BP | 90 | 162.0375 - 174.0 | 30.0 | Amp | F3D |
| BP | 90 | 162.0375 - 174.0 | 30.0 | Amp | F3E |
| BP | 90 | 162.0375 - 174.0 | 30.0 | Amp | G3E |
| BP | 90 | 162.0375 - 174.0 | 30.0 | Amp | G2B |
| Class II change: April 15th, 2021 to replace the primary gain stage transistor with a comparable components that is more robust against electrostatic discharge. Note 1: F1D, F1E, F3D, F3E, G3E, G2B |
| BP: | The output power is continuously variable from the value listed in this entry to 65%-70% of the value listed. |
| Mail To: |