FCC ID H5P-RD-100W

Remote Display

by Topcon Corporation

Grantee Code: H5P   Product Code: RD100W
Latest application date: 2008-03-27

FCC ID Device Details

FCC IDH5P-RD-100W
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeH5P
Product CodeRD100W
Applicant BusinessTopcon Corporation 🇯🇵
Related Domains topcon.co.jp jp.ul.com
Equipment ClassRemote Display
Test FirmUL Japan, Inc. Yamakita EMC Lab.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2405-2475 MHzOriginal Equipment2008-03-27

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2008-03-27PDF 1.2 MB
internal photos pt 1Internal Photos2008-03-27PDF 1.8 MB
internal photos pt 2Internal Photos2008-03-27PDF 213 KB
external photosExternal Photos2008-03-27PDF 867 KB
Id labelID Label/Location Info2008-03-27PDF 118.5 KB
test setup photosTest Setup Photos2008-03-27PDF 203.9 KB
test reportTest Report2008-03-27PDF 1 MB
agent and confidentiality lettersCover Letter(s)2008-03-27PDF 156.2 KB
permission to sign applicationCover Letter(s)2008-03-27PDF 51.9 KB
MPE infoRF Exposure Info2008-03-27PDF 128.5 KB

Application Information

Application IDkG4Xwxv2hJvhE3IhfpE3Ug==
Final Action Date2008-03-27
Application PurposeOriginal Equipment
Applicant FRN0004492401
Model-RD-100W
Frequency Range2405-2475 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionRemote Display
Responsible PartyKazuki Osaragi, Senior Manager, k-osaragi@topcon.co.jp , +81-3-3558-2594
AgentNaoki Naoki Naoki, UL Japan, Inc., Naoki.Sakamoto@jp.ul.com , +81-596-24-8116
Technical ContactTatsuya Arai, UL Japan, Inc., Tatsuya.Arai@jp.ul.com , +81-465-77-1011
Non-Technical ContactYoshinobu Asai, UL Japan, Inc., Yoshinobu.Asai@jp.ul.com , +81-596-24-8116
Test FirmTetsuya Hashimoto, UL Japan, Inc. Yamakita EMC Lab., Tetsuya.Hashimoto@jp.ul.com , 81-596-24-8116
TCB Emailhotline@atcb.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is Conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
kG4Xwxv2hJvhE3IhfpE3Ug==2008-03-27Original Equipment

Equipment Authorization

FrequencyOutputRules
2405-2475 MHz0.001260015C

Grants

TCB Grant - Application kG4Xwxv2hJvhE3IhfpE3Ug==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 03/27/2008

Application Dated: 03/27/2008
Topcon Corporation
75-1, Hasunuma-cho, Itabashi-ku
Tokyo, 174-8580
Japan
 
Attention: Kazuki Osaragi , Senior Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  H5P-RD-100W
Name of Grantee:  Topcon Corporation
Equipment Class: Digital Transmission System
Notes: Remote Display
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.00126  

Output Power listed is Conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application kG4Xwxv2hJvhE3IhfpE3Ug==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Topcon Corporation
75-1, Hasunuma-cho, Itabashi-ku
Tokyo, 174-8580
Japan
  Date of Grant: 03/27/2008

Application Dated: 03/27/2008
 
Attention: Kazuki Osaragi , Senior Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  H5P-RD-100W
Name of Grantee:  Topcon Corporation
Equipment Class: Digital Transmission System
Notes: Remote Display
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.00126  

Output Power listed is Conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: