FCC ID H9PPPT2833

Single-Mode Cellular PDA WAN Terminal

by Symbol Technologies Inc

Grantee Code: H9P   Product Code: PPT2833
Latest application date: 2002-02-25

FCC ID Device Details

FCC IDH9PPPT2833
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeH9P
Product CodePPT2833
Applicant BusinessSymbol Technologies Inc 🇺🇸
Related Domains zebra.com pctestlab.com
Equipment ClassSingle-Mode Cellular PDA WAN Terminal
Test FirmPCTEST Engineering Laboratory, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.04-848.97 MHzOriginal Equipment2002-02-25

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2002-02-25PDF 740.5 KB
Internal Photos1Internal Photos2002-02-25PDF 2 MB
Internal Photos2Internal Photos2002-02-25PDF 2.5 MB
External PhotosExternal Photos2002-02-25PDF 1.6 MB
FCC ID Label and LocationID Label/Location Info2002-02-25PDF 100.2 KB
Antenna SpecificationOperational Description2002-02-25PDF 128.1 KB
Sar Test Setup PhotosRF Exposure Info2002-02-25PDF 1.3 MB
Test Setup PhotosTest Setup Photos2002-02-25PDF 1.3 MB
Amendment Test PlotsTest Report2002-02-25PDF 196.1 KB
Amendment Test ReportTest Report2002-02-25PDF 255 KB
Part 22 Test ReportTest Report2002-02-25PDF 219.6 KB
SAR Test ReportRF Exposure Info2002-02-25PDF 408.9 KB
Test Report Metadata onlyTest Report2002-02-25PDF 723 KB
Attestation StatementsAttestation Statements2002-02-25PDF 144.7 KB
Confidentiality LetterAttestation Statements2002-02-25PDF 53.6 KB
Amendment Cover LetterCover Letter(s)2002-02-25PDF 25.3 KB
Cover LetterCover Letter(s)2002-02-25PDF 70.9 KB
Amendment Dipole Validation PlotRF Exposure Info2002-02-25PDF 98.2 KB
Amendment Probe CalibrationRF Exposure Info2002-02-25PDF 186.5 KB
Amendment SAR DataRF Exposure Info2002-02-25PDF 574.3 KB
Amendment SAR PlotsRF Exposure Info2002-02-25PDF 201.9 KB
Amendment SAR ReportRF Exposure Info2002-02-25PDF 513.1 KB
Amendment Z Scan PlotsRF Exposure Info2002-02-25PDF 61.5 KB
Dipole Validation PlotsRF Exposure Info2002-02-25PDF 116.8 KB
Parts List and Tune Up ProcedureParts List/Tune Up Info2002-02-25PDF 1.4 MB
Probe Calibration DataRF Exposure Info2002-02-25PDF 224 KB
SAR PlotsRF Exposure Info2002-02-25PDF 567.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 22.5 KB
Schematics Metadata onlySchematicsPDF 454.9 KB
Amendment Operational Description Page Metadata onlyOperational DescriptionPDF 43.9 KB
Operational Description Metadata onlyOperational DescriptionPDF 1.4 MB

Application Information

Application IDYhMhsEzJrpjmjBRC4vo4Ag==
Final Action Date2002-02-25
Application PurposeOriginal Equipment
Applicant FRN0011209004
ModelPPT2833
Frequency Range824.04-848.97 MHz
Equipment ClassTNT - Licensed Non-Broadcast Transmitter Worn on Body
Device DescriptionSingle-Mode Cellular PDA WAN Terminal
Responsible PartyQianlin Zhou, Regulatory Specialist, Larry.Zhou@zebra.com , 346-260-3543
AgentRandy Randy Randy, PCTEST Engineering Laboratory Inc., randy@pctestlab.com , 410-290-6652
Technical ContactRandy Ortanez, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com , 410-290-6652
Non-Technical ContactRandy Ortanez, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com , 410-290-6652
Test FirmRandy Ortanez, PCTEST Engineering Laboratory, Inc., ro@pctestlab.com , 410-290-6652
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput is ERP. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 2.5 cm separation between the device, including its antenna whether extended or retracted, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body-worn: 0.32 W/kg

Applications

Application IDDatePurpose
YhMhsEzJrpjmjBRC4vo4Ag==2002-02-25Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.04-848.97 MHz0.48200002.5000000000ppm30K0FXW22.901(d)

Grants

TCB Grant - Application YhMhsEzJrpjmjBRC4vo4Ag==

This application does not exist.

EAS Grant - Application YhMhsEzJrpjmjBRC4vo4Ag==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Symbol Technologies Inc
1 Zebra Plaza
Holtsville, NY 11742
United States
  Date of Grant: 02/25/2002

Application Dated: 10/08/2001
 
Attention: Qianlin Zhou , Regulatory Specialist

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  H9PPPT2833
Name of Grantee:  Symbol Technologies Inc
Equipment Class: Licensed Non-Broadcast Transmitter Worn on Body
Notes: Single-Mode Cellular PDA WAN Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22.901(d) 824.04  -  848.97 0.482 2.5  PM 30K0FXW

Output is ERP. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 2.5 cm separation between the device, including its antenna whether extended or retracted, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body-worn: 0.32 W/kg



Mail To:
Randy Ortanez, President
PCTEST Engineering Laboratory, Inc.
6660-B Dobbin Road
Columbia, MD 21045