FCC ID H9PSPT1846
2.4 GHz Pen Terminal w/ DSS Internal LAN Radio Car
by Symbol Technologies Inc
Grantee Code: H9P Product Code: SPT1846
Latest application date: 2002-02-07
FCC ID Device Details
| FCC ID | H9PSPT1846 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | H9P |
| Product Code | SPT1846 |
| Applicant Business | Symbol Technologies Inc 🇺🇸 |
| Related Domains | |
| Equipment Class | 2.4 GHz Pen Terminal w/ DSS Internal LAN Radio Car |
| Test Firm | PCTEST Engineering Laboratory, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2002-02-07 |
| 2412-2462 MHz | Original Equipment | 2001-11-20 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2002-02-07 | PDF 792.6 KB |
| Users Manual Metadata only | Users Manual | PDF 720.2 KB | |
| Internal Photos | Internal Photos | 2002-02-07 | PDF 3.7 MB |
| Amendment Internal Photos Metadata only | Internal Photos | PDF 1.2 MB | |
| Internal Photos Metadata only | Internal Photos | PDF 2.5 MB | |
| External Photos | External Photos | 2002-02-07 | PDF 1.7 MB |
| FCC ID Label and Location | ID Label/Location Info | 2002-02-07 | PDF 83.7 KB |
| SAR Test Setup Photos | RF Exposure Info | 2002-02-07 | PDF 1.7 MB |
| Test Setup Photos | Test Setup Photos | 2002-02-07 | PDF 749.8 KB |
| Test Report | Test Report | 2002-02-07 | PDF 1.1 MB |
| Grant Metadata only | Test Report | PDF 33.4 KB | |
| Test Report Metadata only | Test Report | PDF 3.4 MB | |
| Attestation Statements | Attestation Statements | 2002-02-07 | PDF 124.3 KB |
| Confidentiality Letter | Attestation Statements | 2002-02-07 | PDF 18.2 KB |
| Attestation Statements Metadata only | Attestation Statements | PDF 120.9 KB | |
| Cover Letter | Cover Letter(s) | 2002-02-07 | PDF 32.3 KB |
| Amendment Cover Letter | Cover Letter(s) | PDF 25.5 KB | |
| Cover Letter | Cover Letter(s) | PDF 29.9 KB | |
| Dipole Validation | RF Exposure Info | 2002-02-07 | PDF 106.1 KB |
| Probe Calibration | RF Exposure Info | 2002-02-07 | PDF 224 KB |
| SAR Report | RF Exposure Info | 2002-02-07 | PDF 407.5 KB |
| SAR Test Plots | RF Exposure Info | 2002-02-07 | PDF 459.3 KB |
| Amendment RF Warning Statement Metadata only | RF Exposure Info | PDF 68.4 KB | |
| Dipole Validation Plots Metadata only | RF Exposure Info | PDF 106.1 KB | |
| Probe Calibration Data Metadata only | RF Exposure Info | PDF 224 KB | |
| SAR Test Data Metadata only | RF Exposure Info | PDF 459.3 KB | |
| Block Diagram Metadata only | Block Diagram | PDF 21.8 KB | |
| Block Diagram Metadata only | Block Diagram | PDF 32.9 KB | |
| Schematics Metadata only | Schematics | PDF 504.9 KB | |
| Schematics Metadata only | Schematics | PDF 517.9 KB | |
| Operational Description Metadata only | Operational Description | PDF 37 KB | |
| Operational Description Metadata only | Operational Description | PDF 41.4 KB |
Application Information
| Application ID | O+JqZcu36ljHIUHHjPfVyA== |
|---|---|
| Final Action Date | 2002-02-07 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0011209004 |
| Model | SPT1846 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | 2.4 GHz Pen Terminal w/ DSS Internal LAN Radio Car |
| Responsible Party | Qianlin Zhou, Regulatory Specialist, Larry.Zhou@zebra.com |
| Agent | Randy Randy Randy, PCTEST Engineering Laboratory Inc., randy@pctestlab.com |
| Technical Contact | Randy Ortanez, PCTEST Engineering Laboratory Inc., randy@pctestlab.com |
| Non-Technical Contact | Randy Ortanez, PCTEST Engineering Laboratory Inc., randy@pctestlab.com |
| Test Firm | Randy Ortanez, PCTEST Engineering Laboratory, Inc., ro@pctestlab.com |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | This transmitter operates with a specific hand-held/laptop computer and has been tested for SAR compliance at 2 cm from the antenna for mobile and hand-held configurations. SAR compliance for body-worn operating configurations is limited to the specific holster tested for this filing. Users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR value is 0.044 W/kg at 100% duty factor. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| O+JqZcu36ljHIUHHjPfVyA== | 2002-02-07 | Original Equipment |
| sdzMU/zyxaezvnIMIUC80g== | 2001-11-20 | Original Equipment |
Grants
TCB Grant - Application sdzMU/zyxaezvnIMIUC80g==
This application does not exist.
EAS Grant - Application sdzMU/zyxaezvnIMIUC80g==
This application currently is not in final status.
TCB Grant - Application O+JqZcu36ljHIUHHjPfVyA==
This application does not exist.
EAS Grant - Application O+JqZcu36ljHIUHHjPfVyA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Symbol Technologies Inc 1 Zebra Plaza Holtsville, NY 11742 United States |
Date of Grant: 02/07/2002 Application Dated: 11/26/2001 |
| Attention: Qianlin Zhou , Regulatory Specialist |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | H9PSPT1846 |
| Name of Grantee: | Symbol Technologies Inc |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | 2.4 GHz Pen Terminal w/ DSS Internal LAN Radio Car |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.135 |
| This transmitter operates with a specific hand-held/laptop computer and has been tested for SAR compliance at 2 cm from the antenna for mobile and hand-held configurations. SAR compliance for body-worn operating configurations is limited to the specific holster tested for this filing. Users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR value is 0.044 W/kg at 100% duty factor. |
| Mail To: |
| Randy Ortanez, President |
| PCTEST Engineering Laboratory Inc. |
| 6660-B Dobbin Road |
| Columbia, MD 21045 |