FCC ID HDCTRC4305
Point to Point Unlicensed UNII Microwave System
by Adtran
Grantee Code: HDC Product Code: TRC4305
Latest application date: 2002-05-29
FCC ID Device Details
| FCC ID | HDCTRC4305 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | HDC |
| Product Code | TRC4305 |
| Applicant Business | Adtran 🇺🇸 |
| Related Domains | |
| Equipment Class | Point to Point Unlicensed UNII Microwave System |
| Test Firm | Washington Laboratories, Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5750-5800 MHz | Original Equipment | 2002-05-29 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Manual | Users Manual | 2002-05-29 | PDF 1.4 MB |
| Internal Photos | Internal Photos | 2002-05-29 | PDF 2.8 MB |
| External Photos | External Photos | 2002-05-29 | PDF 818.6 KB |
| Label | ID Label/Location Info | 2002-05-29 | PDF 14.3 KB |
| Location | ID Label/Location Info | 2002-05-29 | PDF 125.2 KB |
| Baseband Block | Block Diagram | 2002-05-29 | PDF 8.4 KB |
| RF Block | Block Diagram | 2002-05-29 | PDF 7.1 KB |
| Test Setup Pics | Test Setup Photos | 2002-05-29 | PDF 349.1 KB |
| Test Report Part 1 | Test Report | 2002-05-29 | PDF 91.9 KB |
| Test Report Part 2 | Test Report | 2002-05-29 | PDF 2.9 MB |
| Agent Authorization | Cover Letter(s) | 2002-05-29 | PDF 204.7 KB |
| Confid Request | Cover Letter(s) | 2002-05-29 | PDF 150 KB |
| MPE Report | RF Exposure Info | 2002-05-29 | PDF 10.7 KB |
| Baseband Schema Metadata only | Schematics | PDF 1.7 MB | |
| Tx Schema Metadata only | Schematics | PDF 877.2 KB | |
| Theory of Ops Metadata only | Operational Description | PDF 95 KB |
Application Information
| Application ID | VLEMx2bE+GqgyPLZpnklSA== |
|---|---|
| Final Action Date | 2002-05-29 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0005813993 |
| Model | TRC4305 |
| Frequency Range | 5750-5800 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Point to Point Unlicensed UNII Microwave System |
| Responsible Party | Dan Cassidy, Sr Mgr Compliance Engineering, dan.cassidy@adtran.com |
| Agent | Michael Michael Michael, Washington Laboratories, Ltd., mikev@wll.com |
| Technical Contact | Gregory M Snyder, Washington Laboratories, Ltd, gregs@wll.com |
| Test Firm | Michael Violette, Washington Laboratories, Ltd., info@wll.com |
| TCB Email | hotline@americanTCB.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power Output listed is Conducted. The antennas used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 4.6 meters as specified in manual from all persons during normal operation. Users and installers must be provided with antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| VLEMx2bE+GqgyPLZpnklSA== | 2002-05-29 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 5750-5800 MHz | 0.1096000 | 15E |
Grants
TCB Grant - Application VLEMx2bE+GqgyPLZpnklSA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 05/29/2002 Application Dated: 05/29/2002 |
| Adtran |
| 901 Explorer Boulevard |
| Huntsville, AL 35806-2807 |
| Attention: Dan Cassidy , Sr Mgr Compliance Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | HDCTRC4305 |
| Name of Grantee: | Adtran |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Point to Point Unlicensed UNII Microwave System |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15E | 5750.0 - 5800.0 | 0.1096 |
| Power Output listed is Conducted. The antennas used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 4.6 meters as specified in manual from all persons during normal operation. Users and installers must be provided with antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
EAS Grant - Application VLEMx2bE+GqgyPLZpnklSA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Adtran 901 Explorer Boulevard Huntsville, AL 35806-2807 United States |
Date of Grant: 05/29/2002 Application Dated: 05/29/2002 |
| Attention: Dan Cassidy , Sr Mgr Compliance Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | HDCTRC4305 |
| Name of Grantee: | Adtran |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Point to Point Unlicensed UNII Microwave System |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15E | 5750.0 - 5800.0 | 0.1096 |
| Power Output listed is Conducted. The antennas used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 4.6 meters as specified in manual from all persons during normal operation. Users and installers must be provided with antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
| Mail To: |