FCC ID HZB-MB82HP49

Tsunami 8000 Point-to-Point and Point-to-multipoint Product

by Proxim Wireless Corporation

Grantee Code: HZB   Product Code: MB82HP49
Latest application date: 2012-03-15

FCC ID Device Details

FCC IDHZB-MB82HP49
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeHZB
Product CodeMB82HP49
Applicant BusinessProxim Wireless Corporation 🇺🇸
Related Domains proxim.com
Equipment ClassTsunami 8000 Point-to-Point and Point-to-multipoint Product
Test FirmSporton International Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
4945-4985 MHzOriginal Equipment2012-03-15

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2012-03-15PDF 3.1 MB
internal photosInternal Photos2012-03-15PDF 2.6 MB
external photosExternal Photos2012-03-15PDF 419.3 KB
label locationID Label/Location Info2012-03-15PDF 518.3 KB
Test Setup PhotosTest Setup Photos2012-03-15PDF 154.4 KB
test reportTest Report2012-03-15PDF 1.6 MB
LTC requestCover Letter(s)2012-03-15PDF 853.6 KB
PoACover Letter(s)2012-03-15PDF 828 KB
Professional InstallationCover Letter(s)2012-03-15PDF 812.7 KB
MPERF Exposure Info2012-03-15PDF 100.6 KB
Tune UpParts List/Tune Up Info2012-03-15PDF 102.2 KB

Application Information

Application IDUSQRaJMDDhpFhcD2/qVOSw==
Final Action Date2012-03-15
Application PurposeOriginal Equipment
Applicant FRN0005850607
Model-MB82HP49
Frequency Range4945-4985 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionTsunami 8000 Point-to-Point and Point-to-multipoint Product
Responsible PartyCor van de Water, Sr. Regulatory and Compliance Manager, cwater@proxim.com , 408 383 7600
AgentLeo Leo Leo, Sporton Int. Inc., leohuang@sporton.com.tw , 886-3-656-9065
Test FirmAlex Chen, Sporton International Inc., alex@sporton.com.tw , 886-3-327-3456
TCB EmailDollitz.uwe@phoenix-testlab.de
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is peak conducted. This device must be professionally installed. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 50 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures.

Applications

Application IDDatePurpose
USQRaJMDDhpFhcD2/qVOSw==2012-03-15Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
4945-4985 MHz0.0560.6ppm5M10W7D90Y
4945-4985 MHz0.120.6ppm9M20W6D90Y

Grants

TCB Grant - Application USQRaJMDDhpFhcD2/qVOSw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 03/15/2012

Application Dated: 03/15/2012
Proxim Wireless Corporation
47633 Westinghouse Drive
Fremont, CA 94539
 
Attention: Cor van de Water , Sr. Regulatory and Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  HZB-MB82HP49
Name of Grantee:  Proxim Wireless Corporation
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Tsunami 8000 Point-to-Point and Point-to-multipoint Product
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90Y 4945.0  -  4985.0 0.056 0.6  PM 5M10W7D
90Y 4945.0  -  4985.0 0.12 0.6  PM 9M20W6D

Output Power listed is peak conducted. This device must be professionally installed. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 50 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures.

EAS Grant - Application USQRaJMDDhpFhcD2/qVOSw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Proxim Wireless Corporation
47633 Westinghouse Drive
Fremont, CA 94539
United States
  Date of Grant: 03/15/2012

Application Dated: 03/15/2012
 
Attention: Cor van de Water , Sr. Regulatory and Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  HZB-MB82HP49
Name of Grantee:  Proxim Wireless Corporation
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Tsunami 8000 Point-to-Point and Point-to-multipoint Product
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90Y 4945.0  -  4985.0 0.056 0.6  PM 5M10W7D
90Y 4945.0  -  4985.0 0.12 0.6  PM 9M20W6D

Output Power listed is peak conducted. This device must be professionally installed. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 50 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures.