Test FirmIntertek Testing Services NA Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5730-5845 MHzOriginal Equipment2000-06-06

Exhibits

DocumentTypeAvailableFile
letter regarding users manualUsers Manual2000-06-06PDF 28.6 KB
users manualUsers Manual2000-06-06PDF 1.6 MB
back of circuit boardInternal Photos2000-06-06PDF 272.5 KB
internal view fans disconnectedInternal Photos2000-06-06PDF 282.5 KB
internal view of circuit boardInternal Photos2000-06-06PDF 365.9 KB
internal view with fans connectedInternal Photos2000-06-06PDF 264.5 KB
view of port AInternal Photos2000-06-06PDF 197.1 KB
view of port BInternal Photos2000-06-06PDF 189.3 KB
view of portsInternal Photos2000-06-06PDF 192.1 KB
ID label artID Label/Location Info2000-06-06PDF 18.7 KB
location of FCC ID labelID Label/Location Info2000-06-06PDF 1.5 MB
Data regarding antennaOperational Description2000-06-06PDF 56.6 KB
Statement regarding installation of antennaOperational Description2000-06-06PDF 108.3 KB
fcc test reportTest Report2000-06-06PDF 2.3 MB
processing gain test dataTest Report2000-06-06PDF 32.3 KB
processing gain test reportTest Report2000-06-06PDF 335.4 KB
Response to 13472Cover Letter(s)2000-06-06PDF 48.3 KB
authorization letterCover Letter(s)2000-06-06PDF 27.3 KB
letter regarding RF informationRF Exposure Info2000-06-06PDF 55.5 KB
letter regarding change in confidentiality letterCover Letter(s)2000-06-06PDF 24.5 KB
letter requesting name changeCover Letter(s)2000-06-06PDF 71.7 KB
response to 12596Cover Letter(s)2000-06-06PDF 31 KB
second letter of confidentialityCover Letter(s)2000-06-06PDF 52.2 KB
Response to Request 12596 and 12674RF Exposure Info2000-06-06PDF 27.6 KB
Block diagrams Metadata onlyBlock DiagramPDF 40.2 KB
Schematics Metadata onlySchematicsPDF 1.9 MB
Attachment 1 of Response to 13472 (process gain explained) Metadata onlyOperational DescriptionPDF 5.6 KB
Theory of Operation Metadata onlyOperational DescriptionPDF 174.3 KB
additional page of response to 12596 Metadata onlyOperational DescriptionPDF 9.2 KB

Application Information

Application IDhrprgk8sqDTNu2ptbDIxqQ==
Final Action Date2000-06-06
Application PurposeOriginal Equipment
Applicant FRN0005850607
ModelS58-04
Frequency Range5730-5845 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionSpread Spectrum Radio
Responsible PartyKen Lim, Accounting Manager, klim@proxim.com , 408 383 7600
AgentDavid David David, Intertek Testing Services, DChernom@itsqs.com , 650/463-2900
Technical ContactDavid Chernomordik, Intertek Testing Services, DChernom@itsqs.com , 650/463-2900
Non-Technical ContactCaroline Yu, Western Multiplex, cyu@wmux.com , 408/542-5200
Test FirmJohn Quigley, Intertek Testing Services NA Inc., john.quigley@intertek.com , 949-448-4100
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsThis device must be professionally installed, and may only be used in point-to-point applications. Only parabolic antennas may be used as specified in the filing and must be fix-mounted on permanent, outdoor structures, and must provide for a minimum separation distance of 5 meters (15.6 feet) from all persons during device operation. In order to ensure compliance with FCC RF Exposure requirements, the maximum EIRP may not exceed 60.5 dBm. The RF Exposure requirements of Section 1.1307(b)(3) must be satisfied when antennas are co-located at a site. The grantee must coordinate installation with installers and responsible parties to ensure RF Exposure compliance.

Applications

Application IDDatePurpose
hrprgk8sqDTNu2ptbDIxqQ==2000-06-06Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
5730-5845 MHz0.209000015C36

Grants

TCB Grant - Application hrprgk8sqDTNu2ptbDIxqQ==

This application does not exist.

EAS Grant - Application hrprgk8sqDTNu2ptbDIxqQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Proxim Wireless Corporation
2114 Ringwood Avenue
San Jose, CA 95131
United States
  Date of Grant: 06/06/2000

Application Dated: 01/07/2000
 
Attention: Ken Lim , Accounting Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  HZB-S58-04
Name of Grantee:  Proxim Wireless Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Spread Spectrum Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
36 15C 5730.0  -  5845.0 0.209  

This device must be professionally installed, and may only be used in point-to-point applications. Only parabolic antennas may be used as specified in the filing and must be fix-mounted on permanent, outdoor structures, and must provide for a minimum separation distance of 5 meters (15.6 feet) from all persons during device operation. In order to ensure compliance with FCC RF Exposure requirements, the maximum EIRP may not exceed 60.5 dBm. The RF Exposure requirements of Section 1.1307(b)(3) must be satisfied when antennas are co-located at a site. The grantee must coordinate installation with installers and responsible parties to ensure RF Exposure compliance.


36: Certain antennas used with this equipment require a minimum cable length, or have output power limitations as documented in the application.

Mail To:
Courtney Sherbourne, Technical Writer
Intertek Testing Services
1365 Adams Ct.
Menlo Park, CA 94025