FCC ID I88MAX208M

WiMAX Indoor Gateway

by ZyXEL Communications Corporation

Grantee Code: I88   Product Code: MAX208M
Latest application date: 2011-07-05

FCC ID Device Details

FCC IDI88MAX208M
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeI88
Product CodeMAX208M
Applicant BusinessZyXEL Communications Corporation 🇹🇼
Related Domains zyxel.com.tw tw.bureauveritas.com
Equipment ClassWiMAX Indoor Gateway
Test FirmBureau Veritas CPS (H.K.) Ltd. Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2498.5-2687.5 MHzOriginal Equipment2011-07-05

Exhibits

DocumentTypeAvailableFile
User Manual Part 1Users Manual2011-07-05PDF 4.2 MB
User Manual Part 2Users Manual2011-07-05PDF 1.4 MB
Internal PhotosInternal Photos2011-07-05PDF 1 MB
External PhotosExternal Photos2011-07-05PDF 607.8 KB
LabelID Label/Location Info2011-07-05PDF 657.8 KB
Label LocationID Label/Location Info2011-07-05PDF 43.3 KB
Test Setup PhotosTest Setup Photos2011-07-05PDF 154.3 KB
Test ReportTest Report2011-07-05PDF 655.4 KB
Attestation Statement Ad Hoc DeclarationAttestation Statements2011-07-05PDF 16.8 KB
Attestation Statement DL UL RatioAttestation Statements2011-07-05PDF 20.1 KB
Confidentiality RequestCover Letter(s)2011-07-05PDF 24.3 KB
Cover Letter Agent AuthorizationCover Letter(s)2011-07-05PDF 21.6 KB
RF Exposure InfoRF Exposure Info2011-07-05PDF 29.3 KB

Application Information

Application IDTMMTxkhOPC2l/oEqjt31XA==
Final Action Date2011-07-05
Application PurposeOriginal Equipment
Applicant FRN0021059092
ModelMAX208M
Frequency Range2498.5-2687.5 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionWiMAX Indoor Gateway
Responsible PartyEmma Bao, Section Manager, Emma.bao@zyxel.com.tw , 886 3 578-3942
Technical ContactHank Chung, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, hank.chung@tw.bureauveritas.com , 886-3-593-5343
Non-Technical ContactNatacha Chen, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, natacha.chen@tw.bureauveritas.com , 886-3-3183232
Test FirmRichard Chen, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, richard.chen@tw.bureauveritas.com , 886-3-3183232
TCB Emailcertification@curtis-straus.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is conducted. The product is a WiMAX user station. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

Applications

Application IDDatePurpose
TMMTxkhOPC2l/oEqjt31XA==2011-07-05Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
2498.5-2687.5 MHz0.3782.5ppm4M92W7D27
2501-2685 MHz0.3722.5ppm9M81W7D27

Grants

TCB Grant - Application TMMTxkhOPC2l/oEqjt31XA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Curtis-Straus LLC
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 07/05/2011

Application Dated: 07/05/2011
ZyXEL Communications Corporation
No. 2, Gongye E. 9th Road, Hsinchu Science Park
Hsinchu,
Taiwan
 
Attention: Emma Bao , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  I88MAX208M
Name of Grantee:  ZyXEL Communications Corporation
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: WiMAX Indoor Gateway
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 2498.5  -  2687.5 0.378 2.5  PM 4M92W7D
27 2501.0  -  2685.0 0.372 2.5  PM 9M81W7D

Output power is conducted. The product is a WiMAX user station. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

EAS Grant - Application TMMTxkhOPC2l/oEqjt31XA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ZyXEL Communications Corporation
No. 2, Gongye E. 9th Road, Hsinchu Science Park
Hsinchu,
Taiwan
  Date of Grant: 07/05/2011

Application Dated: 07/05/2011
 
Attention: Emma Bao , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  I88MAX208M
Name of Grantee:  ZyXEL Communications Corporation
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: WiMAX Indoor Gateway
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 2498.5  -  2687.5 0.378 2.5  PM 4M92W7D
27 2501.0  -  2685.0 0.372 2.5  PM 9M81W7D

Output power is conducted. The product is a WiMAX user station. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).



Mail To: