FCC ID I88NWD2105

Wireless N-lite USB Adapter

by ZyXEL Communications Corporation

Grantee Code: I88   Product Code: NWD2105
Latest application date: 2010-06-02

FCC ID Device Details

FCC IDI88NWD2105
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeI88
Product CodeNWD2105
Applicant BusinessZyXEL Communications Corporation 🇹🇼
Related Domains zyxel.com.tw tw.bureauveritas.com
Equipment ClassWireless N-lite USB Adapter
Test FirmBureau Veritas CPS (H.K.) Ltd. Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2010-06-02

Exhibits

DocumentTypeAvailableFile
UserMan-1_I88NWD2105Users Manual2010-06-02PDF 1.3 MB
UserMan-2_I88NWD2105Users Manual2010-06-02PDF 1.9 MB
Int Pho_I88NWD2105Internal Photos2010-06-02PDF 372.7 KB
Ext Pho_I88NWD2105External Photos2010-06-02PDF 174.3 KB
Label Loc_I88NWD2105ID Label/Location Info2010-06-02PDF 33.1 KB
Label Smpl_I88NWD2105ID Label/Location Info2010-06-02PDF 276.9 KB
OpDes_I88NWD2105Operational Description2010-06-02PDF 30 KB
TSup (SAR)_I88NWD2105Test Setup Photos2010-06-02PDF 126.4 KB
TSup_I88NWD2105Test Setup Photos2010-06-02PDF 234.5 KB
Test Rpt_I88NWD2105Test Report2010-06-02PDF 819.2 KB
Confidential_I88NWD2105Cover Letter(s)2010-06-02PDF 58.3 KB
Coverletter-Ad hoc declaration_I88NWD2105Cover Letter(s)2010-06-02PDF 24.7 KB
Coverletter-POA_I88NWD2105Cover Letter(s)2010-06-02PDF 26.7 KB
RF Exp Accessory certificate-1RF Exposure Info2010-06-02PDF 2.4 MB
RF Exp Accessory certificate-2RF Exposure Info2010-06-02PDF 2.1 MB
RF Exp Test Rpt-SAR_I88NWD2105_revRF Exposure Info2010-06-02PDF 1.1 MB

Application Information

Application IDK5ENVhllvUwqGyESclsc3w==
Final Action Date2010-06-02
Application PurposeOriginal Equipment
Applicant FRN0021059092
ModelNWD2105
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWireless N-lite USB Adapter
Responsible PartyEmma Bao, Section Manager, Emma.bao@zyxel.com.tw , 886 3 578-3942
Technical ContactHank Chung, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, hank.chung@tw.bureauveritas.com , 886-3-593-5343
Non-Technical ContactZoe Chang, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, zoe.chang@tw.bureauveritas.com , 886-3-3183232
Test FirmRichard Chen, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, richard.chen@tw.bureauveritas.com , 886-3-3183232
TCB Emailcertification@curtis-straus.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. Device is a 1Tx1R draft 802.11bgn USB adapter. SAR compliance has been established in the laptop computer(s) configurations with USB slot(s) configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The highest reported body SAR value is: 0.733 W/kg.

Applications

Application IDDatePurpose
K5ENVhllvUwqGyESclsc3w==2010-06-02Original Equipment

Equipment Authorization

FrequencyOutputRules
2412-2462 MHz0.229000015C

Grants

TCB Grant - Application K5ENVhllvUwqGyESclsc3w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Curtis-Straus LLC
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 06/02/2010

Application Dated: 06/02/2010
ZyXEL Communications Corporation
No. 2, Gongye E. 9th Road, Hsinchu Science Park
Hsinchu,
Taiwan
 
Attention: Emma Bao , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  I88NWD2105
Name of Grantee:  ZyXEL Communications Corporation
Equipment Class: Digital Transmission System
Notes: Wireless N-lite USB Adapter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.229  

Output power listed is conducted. Device is a 1Tx1R draft 802.11bgn USB adapter. SAR compliance has been established in the laptop computer(s) configurations with USB slot(s) configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The highest reported body SAR value is: 0.733 W/kg.

EAS Grant - Application K5ENVhllvUwqGyESclsc3w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ZyXEL Communications Corporation
No. 2, Gongye E. 9th Road, Hsinchu Science Park
Hsinchu,
Taiwan
  Date of Grant: 06/02/2010

Application Dated: 06/02/2010
 
Attention: Emma Bao , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  I88NWD2105
Name of Grantee:  ZyXEL Communications Corporation
Equipment Class: Digital Transmission System
Notes: Wireless N-lite USB Adapter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.229  

Output power listed is conducted. Device is a 1Tx1R draft 802.11bgn USB adapter. SAR compliance has been established in the laptop computer(s) configurations with USB slot(s) configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The highest reported body SAR value is: 0.733 W/kg.



Mail To: