FCC ID IV9FNCV-50R

50 Watts VHF Transceiver

by Kanematsu USA Inc

Grantee Code: IV9   Product Code: FNCV50R
Latest application date: 2005-02-14

FCC ID Device Details

FCC IDIV9FNCV-50R
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeIV9
Product CodeFNCV50R
Applicant BusinessKanematsu USA Inc 🇺🇸
Related Domains kanematsuusa.com
Equipment Class50 Watts VHF Transceiver
Test FirmTimco Engineering, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
134-174 MHzOriginal Equipment2005-02-14

Exhibits

DocumentTypeAvailableFile
USERS MANUALUsers Manual2005-02-14PDF 339.8 KB
INTENRAL PHOTOSInternal Photos2005-02-14PDF 1.6 MB
EXTERNAL PHOTOSExternal Photos2005-02-14PDF 207.3 KB
ID LABEL LOCATIONID Label/Location Info2005-02-14PDF 62.3 KB
ID LABEL SAMPLEID Label/Location Info2005-02-14PDF 75.1 KB
WARNING LABELID Label/Location Info2005-02-14PDF 101.1 KB
SCHEMATICSSchematics2005-02-14PDF 180.9 KB
OPERATIONAL DESCRIPTIONOperational Description2005-02-14PDF 28.9 KB
TEST REPORTTest Report2005-02-14PDF 417.1 KB
PARTS LISTParts List/Tune Up Info2005-02-14PDF 160.4 KB
TUNE UPParts List/Tune Up Info2005-02-14PDF 16.4 KB

Application Information

Application IDZh2+HE3g3exlAMN/IvkezQ==
Final Action Date2005-02-14
Application PurposeOriginal Equipment
Applicant FRN0011333770
ModelFNCV-50R
Frequency Range134-174 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device Description50 Watts VHF Transceiver
Responsible PartyMasa Nishikawa, Manager, mnishikawa@kanematsuusa.com , 847-981-5633
Test FirmS Sanders, Timco Engineering, Inc., info@timcoengr.com , 888-472-2424
TCB Emailtei@timcoengr.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 96 cm from all persons and must not exceed an antenna gain of 0 dBi.

Applications

Application IDDatePurpose
Zh2+HE3g3exlAMN/IvkezQ==2005-02-14Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
134-174 MHz505ppm10K8F3E9
134-174 MHz505ppm15K7F3E9
134-174 MHz55ppm10K8F3E9
134-174 MHz55ppm15K7F3E9

Grants

TCB Grant - Application Zh2+HE3g3exlAMN/IvkezQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 02/14/2005

Application Dated: 02/14/2005
Kanematsu USA Inc
543 West Algonquin Road
Arlington Hts., IL 60005
 
Attention: Masa Nishikawa , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  IV9FNCV-50R
Name of Grantee:  Kanematsu USA Inc
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: 50 Watts VHF Transceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 134.0  -  174.0 50.0 5.0  PM 10K8F3E
90 134.0  -  174.0 50.0 5.0  PM 15K7F3E
90 134.0  -  174.0 5.0 5.0  PM 10K8F3E
90 134.0  -  174.0 5.0 5.0  PM 15K7F3E

Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 96 cm from all persons and must not exceed an antenna gain of 0 dBi.

EAS Grant - Application Zh2+HE3g3exlAMN/IvkezQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Kanematsu USA Inc
543 West Algonquin Road
Arlington Hts., IL 60005
United States
  Date of Grant: 02/14/2005

Application Dated: 02/14/2005
 
Attention: Masa Nishikawa , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  IV9FNCV-50R
Name of Grantee:  Kanematsu USA Inc
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: 50 Watts VHF Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 134.0  -  174.0 50.0 5.0  PM 10K8F3E
90 134.0  -  174.0 50.0 5.0  PM 15K7F3E
90 134.0  -  174.0 5.0 5.0  PM 10K8F3E
90 134.0  -  174.0 5.0 5.0  PM 15K7F3E

Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 96 cm from all persons and must not exceed an antenna gain of 0 dBi.