FCC ID IWD-W1000144

Fiber Fed Remote Unit

by Radio Frequency Systems Inc

Grantee Code: IWD   Product Code: W1000144
Latest application date: 2008-09-11

FCC ID Device Details

FCC IDIWD-W1000144
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeIWD
Product CodeW1000144
Applicant BusinessRadio Frequency Systems Inc 🇺🇸
Related Domains rfsworld.com
Equipment ClassFiber Fed Remote Unit
Test FirmCETECOM ICT Services GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
869-894 MHzOriginal Equipment2008-09-11

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2008-09-11PDF 292.8 KB
Internal PhotosInternal Photos2008-09-11PDF 379.7 KB
External PhotosExternal Photos2008-09-11PDF 128 KB
LabelID Label/Location Info2008-09-11PDF 67.1 KB
Label LocationID Label/Location Info2008-09-11PDF 95.6 KB
Test Setup PhotosTest Setup Photos2008-09-11PDF 324.3 KB
Test ReportTest Report2008-09-11PDF 1.7 MB
Confidentiality RequestCover Letter(s)2008-09-11PDF 118.2 KB
RF Exposure InfoRF Exposure Info2008-09-11PDF 61.7 KB

Application Information

Application IDcP1nwSJ+BuFgVOQgO1zyWw==
Final Action Date2008-09-11
Application PurposeOriginal Equipment
Applicant FRN0009012410
Model-W1000144
Frequency Range869-894 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionFiber Fed Remote Unit
Responsible PartyPaul Carney, Senior RF Engineer, paul.carney@rfsworld.com , 602-722-9684
Test FirmGerald Schmidt, CETECOM ICT Services GmbH, tcb@cetecom.com , 49-681-598-0
TCB Emailgerald.schmidt@ict.cetecom.de
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is peak conducted. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. Downlink (indoor) grant conditions. The antenna used for this transmitter is fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power must satisfy the MPE Categorical Exclusion Requirements of 2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). Downlink (outdoor) grant conditions. The antenna used for this transmitter is fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).

Applications

Application IDDatePurpose
cP1nwSJ+BuFgVOQgO1zyWw==2008-09-11Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
869-894 MHz0.166AmpGXW22H
869-894 MHz0.955AmpF9W22H

Grants

TCB Grant - Application cP1nwSJ+BuFgVOQgO1zyWw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CETECOM ICT Services GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 09/11/2008

Application Dated: 09/11/2008
Radio Frequency Systems Inc
29 Research Parkway
Wallingford, CT 06492
 
Attention: Paul Carney , Senior RF Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  IWD-W1000144
Name of Grantee:  Radio Frequency Systems Inc
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Fiber Fed Remote Unit
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 869.0  -  894.0 0.166  Amp GXW
22H 869.0  -  894.0 0.955  Amp F9W

Power listed is peak conducted. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Downlink (indoor) grant conditions. The antenna used for this transmitter is fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power must satisfy the MPE Categorical Exclusion Requirements of 2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).

Downlink (outdoor) grant conditions. The antenna used for this transmitter is fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).


EAS Grant - Application cP1nwSJ+BuFgVOQgO1zyWw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Radio Frequency Systems Inc
29 Research Parkway
Wallingford, CT 06492
United States
  Date of Grant: 09/11/2008

Application Dated: 09/11/2008
 
Attention: Paul Carney , Senior RF Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  IWD-W1000144
Name of Grantee:  Radio Frequency Systems Inc
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Fiber Fed Remote Unit
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 869.0  -  894.0 0.166  Amp GXW
22H 869.0  -  894.0 0.955  Amp F9W

Power listed is peak conducted. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Downlink (indoor) grant conditions. The antenna used for this transmitter is fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power must satisfy the MPE Categorical Exclusion Requirements of 2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).

Downlink (outdoor) grant conditions. The antenna used for this transmitter is fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).



Mail To: