FCC ID IXM-CBGBR05

U.S. Robotics Wireless Maxg PC Card

by Universal Scientific Industrial Co., Ltd.

Grantee Code: IXM   Product Code: CBGBR05
Latest application date: 2004-12-22

FCC ID Device Details

FCC IDIXM-CBGBR05
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeIXM
Product CodeCBGBR05
Applicant BusinessUniversal Scientific Industrial Co., Ltd. 🇹🇼
Related Domains ms.usi.com.tw
Equipment ClassU.S. Robotics Wireless Maxg PC Card
Test FirmBureau Veritas CPS (H.K.) Ltd. Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2004-12-22

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2004-12-22PDF 655.4 KB
internal photosInternal Photos2004-12-22PDF 123.9 KB
external photosExternal Photos2004-12-22PDF 53.8 KB
label locationID Label/Location Info2004-12-22PDF 124.6 KB
label sampleID Label/Location Info2004-12-22PDF 266.8 KB
operational descriptionOperational Description2004-12-22PDF 57.4 KB
Test setup photosTest Setup Photos2004-12-22PDF 193.5 KB
SAR test reportRF Exposure Info2004-12-22PDF 2.1 MB
Test report 15C part 1Test Report2004-12-22PDF 2.1 MB
Test report 15C part 2Test Report2004-12-22PDF 587.4 KB
DoCCover Letter(s)2004-12-22PDF 46.4 KB
authorization letterCover Letter(s)2004-12-22PDF 35.5 KB
confidentiality requestCover Letter(s)2004-12-22PDF 36 KB
blockdiagram Metadata onlyBlock DiagramPDF 172.5 KB
schematics Metadata onlySchematicsPDF 80.7 KB

Application Information

Application IDL0/7fq+ILVvOAl0FkpnaBg==
Final Action Date2004-12-22
Application PurposeOriginal Equipment
Applicant FRN0007326382
ModelCBGBR05
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionU.S. Robotics Wireless Maxg PC Card
Responsible PartyMartin Shih, Section Manager, martins@ms.usi.com.tw , 886-49-2350876
AgentEric Eric Eric, Advance Data Technology Corporation, eric_lin@adt.com.tw , +886 3593 5343
Technical ContactEric Lin, Advance Data Technology Corporation, eric_lin@adt.com.tw , +886 3593 5343
Test FirmRichard Chen, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, richard.chen@tw.bureauveritas.com , 886-3-3183232
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted. SAR compliance has been established in a laptop computer configuration with side PCMCIA slot configuration as tested in this filing, and can be used in laptop/notebook computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. The antenna of the device must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. Maximum measured SAR value: 0.131W/kg (Body).

Applications

Application IDDatePurpose
L0/7fq+ILVvOAl0FkpnaBg==2004-12-22Original Equipment

Equipment Authorization

FrequencyOutputRules
2412-2462 MHz0.072000015C

Grants

TCB Grant - Application L0/7fq+ILVvOAl0FkpnaBg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/22/2004

Application Dated: 12/22/2004
Universal Scientific Industrial Co., Ltd.
141, Lane 351, Sec. 1, Taiping Road,
P.O. Box 54261,
Tsaotueng, Nantou,
Taiwan
 
Attention: Martin Shih , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  IXM-CBGBR05
Name of Grantee:  Universal Scientific Industrial Co., Ltd.
Equipment Class: Digital Transmission System
Notes: U.S. Robotics Wireless Maxg PC Card
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.072  

Power output listed is conducted. SAR compliance has been established in a laptop computer configuration with side PCMCIA slot configuration as tested in this filing, and can be used in laptop/notebook computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. The antenna of the device must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. Maximum measured SAR value: 0.131W/kg (Body).

EAS Grant - Application L0/7fq+ILVvOAl0FkpnaBg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Universal Scientific Industrial Co., Ltd.
141, Lane 351, Sec. 1, Taiping Road, P.O. Box 54261,
Tsaotueng, Nantou,
Taiwan
  Date of Grant: 12/22/2004

Application Dated: 12/22/2004
 
Attention: Martin Shih , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  IXM-CBGBR05
Name of Grantee:  Universal Scientific Industrial Co., Ltd.
Equipment Class: Digital Transmission System
Notes: U.S. Robotics Wireless Maxg PC Card
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.072  

Power output listed is conducted. SAR compliance has been established in a laptop computer configuration with side PCMCIA slot configuration as tested in this filing, and can be used in laptop/notebook computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. The antenna of the device must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. Maximum measured SAR value: 0.131W/kg (Body).



Mail To: