FCC ID IXM-CFGMR01
WIRELESS 802.11g CF CARD
by Universal Scientific Industrial Co., Ltd.
Grantee Code: IXM Product Code: CFGMR01
Latest application date: 2006-06-30
FCC ID Device Details
| FCC ID | IXM-CFGMR01 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | IXM |
| Product Code | CFGMR01 |
| Applicant Business | Universal Scientific Industrial Co., Ltd. 🇹🇼 |
| Related Domains | |
| Equipment Class | WIRELESS 802.11g CF CARD |
| Test Firm | SPORTON International Inc |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2006-06-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| USERS MANUAL | Users Manual | 2006-06-30 | PDF 62.3 KB |
| INTERNAL PHOTOS | Internal Photos | 2006-06-30 | PDF 175.6 KB |
| EXTERNAL PHOTOS | External Photos | 2006-06-30 | PDF 49.1 KB |
| LABEL | ID Label/Location Info | 2006-06-30 | PDF 179.8 KB |
| LABEL LOCATION | ID Label/Location Info | 2006-06-30 | PDF 34.1 KB |
| TEST SETUP PHOTOS | Test Setup Photos | 2006-06-30 | PDF 157.1 KB |
| TEST REPORT | Test Report | 2006-06-30 | PDF 2.8 MB |
| CONFIDENTIALITY LETTER | Cover Letter(s) | 2006-06-30 | PDF 146 KB |
| RF EXPOSURE | RF Exposure Info | 2006-06-30 | PDF 3.2 MB |
| BLOCK DIAGRAM Metadata only | Block Diagram | PDF 14.7 KB | |
| SCHEMATICS Metadata only | Schematics | PDF 121 KB | |
| OPERATIONAL DESCRIPTION Metadata only | Operational Description | PDF 12 KB | |
| PARTS LIST Metadata only | Parts List/Tune Up Info | PDF 50.4 KB |
Application Information
| Application ID | 8JcS/AEsBR6dNNBSnhBkZg== |
|---|---|
| Final Action Date | 2006-06-30 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0007326382 |
| Model | CFGMR01 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | WIRELESS 802.11g CF CARD |
| Responsible Party | Martin Shih, Section Manager, martins@ms.usi.com.tw |
| Test Firm | Kathy Lin, SPORTON International Inc, kathylin@sporton.com.tw |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. SAR compliance has been established in the laptop computer(s) configurations with CompactFlash slot on the side near the rear and in PDA(s) configuration(s) with CompactFlash slot on the top as tested in this filing, and can be used in laptop computer(s) and PDA(s) with substantially similar physical dimensions, construction, and electrical and RF characteristics. SAR compliance for body-worn operations with PDA(s) is restricted to belt-clips, holsters, and accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device, including its antenna, and the users body. Compliance of this device in all final host configurations is the responsibility of the Grantee. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. The highest reported SAR level is: Body: 1.26 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 8JcS/AEsBR6dNNBSnhBkZg== | 2006-06-30 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2412-2462 MHz | 0.0600000 | 15C |
Grants
TCB Grant - Application 8JcS/AEsBR6dNNBSnhBkZg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 06/30/2006 Application Dated: 06/30/2006 |
| Universal Scientific Industrial Co., Ltd. |
| 141, Lane 351, Sec. 1, Taiping Road, |
| P.O. Box 54261, |
| Tsaotueng, Nantou, Taiwan |
| Attention: Martin Shih , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | IXM-CFGMR01 |
| Name of Grantee: | Universal Scientific Industrial Co., Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | WIRELESS 802.11g CF CARD |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.06 |
| Power listed is conducted. SAR compliance has been established in the laptop computer(s) configurations with CompactFlash slot on the side near the rear and in PDA(s) configuration(s) with CompactFlash slot on the top as tested in this filing, and can be used in laptop computer(s) and PDA(s) with substantially similar physical dimensions, construction, and electrical and RF characteristics. SAR compliance for body-worn operations with PDA(s) is restricted to belt-clips, holsters, and accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device, including its antenna, and the users body. Compliance of this device in all final host configurations is the responsibility of the Grantee. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. The highest reported SAR level is: Body: 1.26 W/kg. |
EAS Grant - Application 8JcS/AEsBR6dNNBSnhBkZg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Universal Scientific Industrial Co., Ltd. 141, Lane 351, Sec. 1, Taiping Road, P.O. Box 54261, Tsaotueng, Nantou, Taiwan |
Date of Grant: 06/30/2006 Application Dated: 06/30/2006 |
| Attention: Martin Shih , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | IXM-CFGMR01 |
| Name of Grantee: | Universal Scientific Industrial Co., Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | WIRELESS 802.11g CF CARD |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.06 |
| Power listed is conducted. SAR compliance has been established in the laptop computer(s) configurations with CompactFlash slot on the side near the rear and in PDA(s) configuration(s) with CompactFlash slot on the top as tested in this filing, and can be used in laptop computer(s) and PDA(s) with substantially similar physical dimensions, construction, and electrical and RF characteristics. SAR compliance for body-worn operations with PDA(s) is restricted to belt-clips, holsters, and accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device, including its antenna, and the users body. Compliance of this device in all final host configurations is the responsibility of the Grantee. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. The highest reported SAR level is: Body: 1.26 W/kg. |
| Mail To: |