FCC ID IZP70101-R001

Utility Network Telemetry and Control Device

by Echelon Corporation

Grantee Code: IZP   Product Code: 70101R001
Latest application date: 2011-07-05

FCC ID Device Details

FCC IDIZP70101-R001
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeIZP
Product Code70101R001
Applicant BusinessEchelon Corporation 🇺🇸
Related Domains echelon.com
Equipment ClassUtility Network Telemetry and Control Device
Test FirmMET Laboratories, Incorporated

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.7-848.31 MHzOriginal Equipment2011-07-05

Exhibits

DocumentTypeAvailableFile
Installation GuideUsers Manual2011-07-05PDF 2.2 MB
CDMA Module Internal PhotosInternal Photos2011-07-05PDF 185.6 KB
Internal Photos Part 1Internal Photos2011-07-05PDF 3.8 MB
Internal Photos Part 2Internal Photos2011-07-05PDF 3.4 MB
External PhotosExternal Photos2011-07-05PDF 435.7 KB
LabelID Label/Location Info2011-07-05PDF 104.8 KB
Test Setup PhotosTest Setup Photos2011-07-05PDF 463.6 KB
Modular Approved Test ReportTest Report2011-07-05PDF 1.2 MB
Test ReportTest Report2011-07-05PDF 1,002.4 KB
Confidentiality Request LetterCover Letter(s)2011-07-05PDF 13.4 KB
Series matrixCover Letter(s)2011-07-05PDF 87 KB
Antenna DatasheetRF Exposure Info2011-07-05PDF 251.5 KB
Antenna DesignRF Exposure Info2011-07-05PDF 117.9 KB
GPS Receive AntennaRF Exposure Info2011-07-05PDF 90.9 KB
MPERF Exposure Info2011-07-05PDF 281.6 KB

Application Information

Application IDxxB2hXw+6uH9MTIdMcq1iA==
Final Action Date2011-07-05
Application PurposeOriginal Equipment
Applicant FRN0017721382
Model70101-R001
Frequency Range824.7-848.31 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionUtility Network Telemetry and Control Device
Responsible PartyYaqoob I Bhimla, Sr. Regulatory Compliance Engineer, ybhimla@echelon.com , 408-938-5353
Technical ContactGilles van Ruymbeke, Echelon Corporation, gilles@echelon.com , (408) 790-3106
Non-Technical ContactStuart Bright, Echelon Corporation, sbright@echelon.com , 01144 1923 430 100
Test FirmRobert Frier, MET Laboratories, Incorporated, rfrier@metlabs.com , 410-949-1805
TCB Emailtcbinfo@metlabs.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is ERP for Part 22 and EIRP for Part 24 The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 28 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
xxB2hXw+6uH9MTIdMcq1iA==2011-07-05Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.7-848.31 MHz0.2472.5ppm1M29F9W22H
1851.25-1908.75 MHz0.4082.5ppm1M29F9W24E

Grants

TCB Grant - Application xxB2hXw+6uH9MTIdMcq1iA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MET Laboratories, Inc.
914 W. Patapsco Avenue
Baltimore, MD 21230-3432
Date of Grant: 07/05/2011

Application Dated: 07/05/2011
Echelon Corporation
550 Meridian Ave
San Jose, CA 95126
 
Attention: Yaqoob Bhimla , Sr. Regulatory Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  IZP70101-R001
Name of Grantee:  Echelon Corporation
Equipment Class: PCS Licensed Transmitter
Notes: Utility Network Telemetry and Control Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.247 2.5  PM 1M29F9W
24E 1851.25  -  1908.75 0.408 2.5  PM 1M29F9W

Output power listed is ERP for Part 22 and EIRP for Part 24 The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 28 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application xxB2hXw+6uH9MTIdMcq1iA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Echelon Corporation
550 Meridian Ave
San Jose, CA 95126
United States
  Date of Grant: 07/05/2011

Application Dated: 07/05/2011
 
Attention: Yaqoob Bhimla , Sr. Regulatory Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  IZP70101-R001
Name of Grantee:  Echelon Corporation
Equipment Class: PCS Licensed Transmitter
Notes: Utility Network Telemetry and Control Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.247 2.5  PM 1M29F9W
24E 1851.25  -  1908.75 0.408 2.5  PM 1M29F9W

Output power listed is ERP for Part 22 and EIRP for Part 24 The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 28 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.