FCC ID J3OWCB5000

Cardbus Wireless LAN Adapter

by Xircom

Grantee Code: J3O   Product Code: WCB5000
Latest application date: 2001-12-18

FCC ID Device Details

FCC IDJ3OWCB5000
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeJ3O
Product CodeWCB5000
Applicant BusinessXircom 🇺🇸
Related Domains intel.com
Equipment ClassCardbus Wireless LAN Adapter
Test FirmElliott Laboratories LLC

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5320 MHzOriginal Equipment2001-12-18

Exhibits

DocumentTypeAvailableFile
Install GuideUsers Manual2001-12-18PDF 489.4 KB
Regulatory InfoUsers Manual2001-12-18PDF 103.2 KB
Internal PhotoInternal Photos2001-12-18PDF 456 KB
External PhotosExternal Photos2001-12-18PDF 171.1 KB
Label and LocationID Label/Location Info2001-12-18PDF 197.6 KB
Test Configuration PhotosTest Setup Photos2001-12-18PDF 434.1 KB
Test ReportTest Report2001-12-18PDF 433 KB
Drug AttestationCover Letter(s)2001-12-18PDF 263.5 KB
ATCB CommentsCover Letter(s)2001-12-18PDF 13.7 KB
POACover Letter(s)2001-12-18PDF 467.4 KB
Response to ATCBCover Letter(s)2001-12-18PDF 30.9 KB
Revised Confid LetterCover Letter(s)2001-12-18PDF 463.7 KB
MPE CalculationRF Exposure Info2001-12-18PDF 384 KB
Revised Block Diagram Metadata onlyBlock DiagramPDF 19 KB
Schema Metadata onlySchematicsPDF 768.2 KB
Antenna Metadata onlyOperational DescriptionPDF 1.4 MB
Theory of Ops Metadata onlyOperational DescriptionPDF 19.5 KB
Theory of Ops Addendum Metadata onlyOperational DescriptionPDF 135 KB

Application Information

Application IDmzrlc5PStrzKlX/IdRYRMQ==
Final Action Date2001-12-18
Application PurposeOriginal Equipment
Applicant FRN0004987038
ModelWCB5000
Frequency Range5180-5320 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionCardbus Wireless LAN Adapter
Responsible PartyRobert W. Paxman, Compliance Engineer, robert.paxman@intel.com , 805-376-9300
AgentJuan Juan Juan, Elliott Laboratories, Inc., doc@elliottlabs.com , 408 245 7800
Technical ContactJuan Martinez, Elliott Laboratories, Inc., doc@elliottlabs.com , 408 245 7800
Test FirmDavid Bare, Elliott Laboratories LLC, dbare@elliottlabs.com , 408-245-7800
TCB Emailhotline@americanTCB.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is Conducted. The installation and operating configurations of this transmitter, including the antenna gain and cable loss, must satisfy MPE Categorical Exclusion Requirements of §2.1091. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
mzrlc5PStrzKlX/IdRYRMQ==2001-12-18Original Equipment

Equipment Authorization

FrequencyOutputRules
5180-5320 MHz0.035000015E

Grants

TCB Grant - Application mzrlc5PStrzKlX/IdRYRMQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 12/18/2001

Application Dated: 12/18/2001
Xircom
2300 Corporate Center Drive
Thousand Oaks, CA 91320
 
Attention: Robert Paxman , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  J3OWCB5000
Name of Grantee:  Xircom
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Cardbus Wireless LAN Adapter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15E 5180.0  -  5320.0 0.035  

Power Output listed is Conducted. The installation and operating configurations of this transmitter, including the antenna gain and cable loss, must satisfy MPE Categorical Exclusion Requirements of §2.1091. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application mzrlc5PStrzKlX/IdRYRMQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Xircom
2300 Corporate Center Drive
Thousand Oaks, CA 91320
United States
  Date of Grant: 12/18/2001

Application Dated: 12/18/2001
 
Attention: Robert Paxman , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  J3OWCB5000
Name of Grantee:  Xircom
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Cardbus Wireless LAN Adapter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15E 5180.0  -  5320.0 0.035  

Power Output listed is Conducted. The installation and operating configurations of this transmitter, including the antenna gain and cable loss, must satisfy MPE Categorical Exclusion Requirements of §2.1091. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: