FCC ID JPAVOR2

VOR Transmitter

by Selex Sistemi Integrati Inc.

Grantee Code: JPA   Product Code: VOR2
Latest application date: 2009-04-28

FCC ID Device Details

FCC IDJPAVOR2
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeJPA
Product CodeVOR2
Applicant BusinessSelex Sistemi Integrati Inc. 🇺🇸
Related Domains selex-si-us.com
Equipment ClassVOR Transmitter
Test FirmBay Area Compliance Laboratory

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
108-117.95 MHzOriginal Equipment2009-04-28

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2009-04-28PDF 3.5 MB
Internal PhotosInternal Photos2009-04-28PDF 2.5 MB
External PhotosExternal Photos2009-04-28PDF 98 KB
FCC ID LabelID Label/Location Info2009-04-28PDF 35.5 KB
Test Setup PhotosTest Setup Photos2009-04-28PDF 426.6 KB
Test ReportTest Report2009-04-28PDF 360.5 KB
Confidential Request LetterCover Letter(s)2009-04-28PDF 34.4 KB
FAA LetterCover Letter(s)2009-04-28PDF 139.8 KB
Letter to FAACover Letter(s)2009-04-28PDF 32.5 KB

Application Information

Application IDHz55utMXQ1SAbdSXHzSNxw==
Final Action Date2009-04-28
Application PurposeOriginal Equipment
Applicant FRN0006900500
ModelVOR2
Frequency Range108-117.95 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionVOR Transmitter
Responsible PartyKurt A Rieke, Product Manager, rieke@selex-si-us.com , 913-495-2666
Test FirmJohn Chan, Bay Area Compliance Laboratory, bacl.regulatory@baclcorp.com , 408-732-9162
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeB3: Maritime & Aviation Radio Services equipment in 47 CFR parts 80 & 87
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is Maximum conducted at the antenna terminal. This device is Data VOR transmitter. The antenna used for this transmitter is to be fixed-mounted on permanent structures. RF exposure compliance must be addressed at the time of licensing, including antenna co-location requirements of 1.1307(b)(3).

Applications

Application IDDatePurpose
Hz55utMXQ1SAbdSXHzSNxw==2009-04-28Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
108-117.95 MHz100.000000020.0000000000ppm21K0A9W87BG

Grants

TCB Grant - Application Hz55utMXQ1SAbdSXHzSNxw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 04/28/2009

Application Dated: 04/28/2009
Selex Sistemi Integrati Inc.
11300 West 89th Street
Overland Park, KS 66214
 
Attention: Kurt Rieke , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  JPAVOR2
Name of Grantee:  Selex Sistemi Integrati Inc.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: VOR Transmitter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BG 87 108.0  -  117.95 100.0 20.0  PM 21K0A9W

Power listed is Maximum conducted at the antenna terminal. This device is Data VOR transmitter. The antenna used for this transmitter is to be fixed-mounted on permanent structures. RF exposure compliance must be addressed at the time of licensing, including antenna co-location requirements of 1.1307(b)(3).

BG: The output power is continuously variable from the value listed in this entry to 25%-30% of the value listed.

EAS Grant - Application Hz55utMXQ1SAbdSXHzSNxw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Selex Sistemi Integrati Inc.
11300 West 89th Street
Overland Park, KS 66214
United States
  Date of Grant: 04/28/2009

Application Dated: 04/28/2009
 
Attention: Kurt Rieke , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  JPAVOR2
Name of Grantee:  Selex Sistemi Integrati Inc.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: VOR Transmitter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BG 87 108.0  -  117.95 100.0 20.0  PM 21K0A9W

Power listed is Maximum conducted at the antenna terminal. This device is Data VOR transmitter. The antenna used for this transmitter is to be fixed-mounted on permanent structures. RF exposure compliance must be addressed at the time of licensing, including antenna co-location requirements of 1.1307(b)(3).


BG: The output power is continuously variable from the value listed in this entry to 25%-30% of the value listed.