FCC ID JTEGWMT1920
Test transmitter
by Andrew Network Solutions Group
Grantee Code: JTE Product Code: GWMT1920
Latest application date: 2001-12-21
FCC ID Device Details
| FCC ID | JTEGWMT1920 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | JTE |
| Product Code | GWMT1920 |
| Applicant Business | Andrew Network Solutions Group 🇺🇸 |
| Related Domains | |
| Equipment Class | Test transmitter |
| Test Firm | Nemko Dallas, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1850-1910 MHz | Original Equipment | 2001-12-21 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Manual | Users Manual | 2001-12-21 | PDF 634.8 KB |
| Internal photos | Internal Photos | 2001-12-21 | PDF 1.3 MB |
| External photos | External Photos | 2001-12-21 | PDF 282.8 KB |
| Label details | ID Label/Location Info | 2001-12-21 | PDF 6.5 KB |
| Block diagram | Block Diagram | 2001-12-21 | PDF 13.1 KB |
| Operational description | Operational Description | 2001-12-21 | PDF 3.4 KB |
| Test setup photos | Test Setup Photos | 2001-12-21 | PDF 205.6 KB |
| Test report | Test Report | 2001-12-21 | PDF 634.6 KB |
| Voltage and current in RF stage | Test Report | 2001-12-21 | PDF 4.2 KB |
| Request for confidentiality | Cover Letter(s) | 2001-12-21 | PDF 56.5 KB |
| MPE prediction | RF Exposure Info | 2001-12-21 | PDF 72.3 KB |
| Tune up procedure | Parts List/Tune Up Info | 2001-12-21 | PDF 634.8 KB |
| Schematics Metadata only | Schematics | PDF 845.9 KB |
Application Information
| Application ID | pXkqMdbs+oIxwM7xGNsFzg== |
|---|---|
| Final Action Date | 2001-12-21 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0005903026 |
| Model | GWMT1920 |
| Frequency Range | 1850-1910 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Test transmitter |
| Responsible Party | Kent Bell, Director of Hardware Engineering, kent.bell@andrew.com |
| Test Firm | Michael Cantwell, Nemko Dallas, Inc., @., 972-436-9600 |
| TCB Email | certification@curtis-straus.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Grant Conditions - The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 20 W and the peak radiated output power must not exceed 1000 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| pXkqMdbs+oIxwM7xGNsFzg== | 2001-12-21 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application pXkqMdbs+oIxwM7xGNsFzg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bureau Veritas Consumer Products Services, Inc. One Distribution Center Circle Suite #1 Littleton, MA 01460 |
Date of Grant: 12/21/2001 Application Dated: 12/21/2001 |
| Andrew Network Solutions Group |
| 140 Vista Centre Dr. |
| Forest, VA 24551 |
| Attention: Kent Bell , Director of Hardware Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | JTEGWMT1920 |
| Name of Grantee: | Andrew Network Solutions Group |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Test transmitter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 24E | 1930.0 - 1990.0 | 20.0 | NON | |
| BC | 24E | 1850.0 - 1910.0 | 20.0 | NON |
| Grant Conditions - The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 20 W and the peak radiated output power must not exceed 1000 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
EAS Grant - Application pXkqMdbs+oIxwM7xGNsFzg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Andrew Network Solutions Group 140 Vista Centre Dr. Forest, VA 24551 United States |
Date of Grant: 12/21/2001 Application Dated: 12/21/2001 |
| Attention: Kent Bell , Director of Hardware Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | JTEGWMT1920 |
| Name of Grantee: | Andrew Network Solutions Group |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Test transmitter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 24E | 1930.0 - 1990.0 | 20.0 | NON | |
| BC | 24E | 1850.0 - 1910.0 | 20.0 | NON |
| Grant Conditions - The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 20 W and the peak radiated output power must not exceed 1000 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
| Mail To: |