FCC ID JVPA38

GSM Mobile Phone

by Benq Corporation

Grantee Code: JVP   Product Code: A38
Latest application date: 2006-06-28

FCC ID Device Details

FCC IDJVPA38
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeJVP
Product CodeA38
Applicant BusinessBenq Corporation 🇹🇼
Related Domains benq.com
Equipment ClassGSM Mobile Phone
Test FirmQuieTek Corporation

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1850.2-1909.8 MHzOriginal Equipment2006-06-28

Exhibits

DocumentTypeAvailableFile
Prelim ManualUsers Manual2006-06-28PDF 816.3 KB
Int PhotosInternal Photos2006-06-28PDF 1.8 MB
Ext PhotosExternal Photos2006-06-28PDF 375.9 KB
Label and LocationID Label/Location Info2006-06-28PDF 124.2 KB
Op DescriptOperational Description2006-06-28PDF 67.7 KB
Test SetupTest Setup Photos2006-06-28PDF 391.5 KB
Revised Test ReportTest Report2006-06-28PDF 3.1 MB
AttestationCover Letter(s)2006-06-28PDF 121.6 KB
ATCB CommentsCover Letter(s)2006-06-28PDF 46.9 KB
Agent AuthorizationCover Letter(s)2006-06-28PDF 28.9 KB
Confid RequestCover Letter(s)2006-06-28PDF 89.9 KB
SAR Part 1RF Exposure Info2006-06-28PDF 2.4 MB
SAR Part 2RF Exposure Info2006-06-28PDF 3.2 MB
Block Metadata onlyBlock DiagramPDF 245.6 KB
Schema Metadata onlySchematicsPDF 153 KB
Parts Metadata onlyParts List/Tune Up InfoPDF 50.3 KB
Tune Up Metadata onlyParts List/Tune Up InfoPDF 58.6 KB

Application Information

Application IDFQog669/pIlUziauyS5K4Q==
Final Action Date2006-06-28
Application PurposeOriginal Equipment
Applicant FRN0006817563
ModelA38
Frequency Range1850.2-1909.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionGSM Mobile Phone
Responsible PartyWenny Lan, Sr. Director, System & Product Regulatory, Wenny.Lan@BenQ.com , +886-2-2658-8800
Technical ContactMicki Ho, QuieTek Corporation, mickiho@quietek.com , +886 2 8792 6808
Non-Technical ContactBlair Wang, BenQ Corporation, blair.wang@benq.com , +886 3 359 8800
Test FirmKevin (Yu-Lung) Chen, QuieTek Corporation, kevincyl@quietek.com , 886-2-87926808
TCB Emailhotline@atcb.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsThis device contains GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz Licensed PCS operations. Power Output is EIRP. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user’s body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 0.37W/kg; Body-worn: 0.52W/kg

Applications

Application IDDatePurpose
FQog669/pIlUziauyS5K4Q==2006-06-28Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
1850.2-1909.8 MHz0.88500000.1000000000ppm300KGXW24EBC

Grants

TCB Grant - Application FQog669/pIlUziauyS5K4Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 06/28/2006

Application Dated: 06/27/2006
Benq Corporation
16 Jihu Road, Neihu, Taipei 114, Taiwan
Taipei, 114
Taiwan
 
Attention: Wenny Lan , Sr. Director, System & Product Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  JVPA38
Name of Grantee:  Benq Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: GSM Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 24E 1850.2  -  1909.8 0.885 0.1  PM 300KGXW

This device contains GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz Licensed PCS operations.

Power Output is EIRP. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user’s body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 0.37W/kg; Body-worn: 0.52W/kg


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application FQog669/pIlUziauyS5K4Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Benq Corporation
16 Jihu Road, Neihu, Taipei 114, Taiwan
Taipei, 114
Taiwan
  Date of Grant: 06/28/2006

Application Dated: 06/27/2006
 
Attention: Wenny Lan , Sr. Director, System & Product Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  JVPA38
Name of Grantee:  Benq Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: GSM Mobile Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 24E 1850.2  -  1909.8 0.885 0.1  PM 300KGXW

This device contains GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz Licensed PCS operations.

Power Output is EIRP. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user’s body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 0.37W/kg; Body-worn: 0.52W/kg


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To: