FCC ID JVPS668C

Tri-Band Mobile Phone

by Benq Corporation

Grantee Code: JVP   Product Code: S668C
Latest application date: 2004-10-04

FCC ID Device Details

FCC IDJVPS668C
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeJVP
Product CodeS668C
Applicant BusinessBenq Corporation 🇹🇼
Related Domains benq.com
Equipment ClassTri-Band Mobile Phone

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1850.2-1909.8 MHzOriginal Equipment2004-10-04

Exhibits

DocumentTypeAvailableFile
Manual 1 revisedUsers Manual2004-10-04PDF 2.9 MB
Manual 2Users Manual2004-10-04PDF 1.5 MB
Internal photosInternal Photos2004-10-04PDF 1.8 MB
External photosExternal Photos2004-10-04PDF 401.5 KB
FCC ID labelID Label/Location Info2004-10-04PDF 85.2 KB
FCC ID label locationID Label/Location Info2004-10-04PDF 63.1 KB
Operational descriptionOperational Description2004-10-04PDF 8.4 KB
Test report revisedTest Report2004-10-04PDF 826.1 KB
ATCB commentsCover Letter(s)2004-10-04PDF 32.4 KB
POACover Letter(s)2004-10-04PDF 31.7 KB
Request for confidentialityCover Letter(s)2004-10-04PDF 100.6 KB
Calibration info 1RF Exposure Info2004-10-04PDF 3.5 MB
SAR 3RF Exposure Info2004-10-04PDF 2 MB
SAR 4RF Exposure Info2004-10-04PDF 3.2 MB
SAR 5RF Exposure Info2004-10-04PDF 3.1 MB
SAR revisedRF Exposure Info2004-10-04PDF 2.8 MB
Block diagram nad description Metadata onlyBlock DiagramPDF 1.1 MB
Schematics Metadata onlySchematicsPDF 167.1 KB
Parts list Metadata onlyParts List/Tune Up InfoPDF 105.9 KB
Tune up Metadata onlyParts List/Tune Up InfoPDF 142.5 KB

Application Information

Application IDT7J6UPLxtnc6AqAC44E2Ow==
Final Action Date2004-10-04
Application PurposeOriginal Equipment
Applicant FRN0006817563
ModelS668C
Frequency Range1850.2-1909.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionTri-Band Mobile Phone
Responsible PartyWenny Lan, Sr. Director, System & Product Regulatory, Wenny.Lan@BenQ.com , +886-2-2658-8800
AgentEllis Ellis Ellis, Advance Data Technology Corporation, ellis@adt.com.tw , 886-3-318-3232
Technical ContactEllis Wu, Advance Data Technology Corporation, ellis@adt.com.tw , 886-3-318-3232
TCB Emailhotline@americantcb.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is EIRP. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 0.635W/kg; Body-worn 0.391 W/kg; This device contains 900/1900 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations.

Applications

Application IDDatePurpose
T7J6UPLxtnc6AqAC44E2Ow==2004-10-04Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
1850.2-1909.8 MHz0.93800000.0340000000ppm314KGXW24EBC

Grants

TCB Grant - Application T7J6UPLxtnc6AqAC44E2Ow==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 10/04/2004

Application Dated: 10/04/2004
Benq Corporation
16 Jihu Road, Neihu, Taipei 114, Taiwan
Taipei, 114
Taiwan
 
Attention: Wenny Lan , Sr. Director, System & Product Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  JVPS668C
Name of Grantee:  Benq Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Tri-Band Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 24E 1850.2  -  1909.8 0.938 0.034  PM 314KGXW

Power Output is EIRP. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 0.635W/kg; Body-worn 0.391 W/kg;

This device contains 900/1900 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application T7J6UPLxtnc6AqAC44E2Ow==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Benq Corporation
16 Jihu Road, Neihu, Taipei 114, Taiwan
Taipei, 114
Taiwan
  Date of Grant: 10/04/2004

Application Dated: 10/04/2004
 
Attention: Wenny Lan , Sr. Director, System & Product Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  JVPS668C
Name of Grantee:  Benq Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Tri-Band Mobile Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 24E 1850.2  -  1909.8 0.938 0.034  PM 314KGXW

Power Output is EIRP. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 0.635W/kg; Body-worn 0.391 W/kg;

This device contains 900/1900 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.