FCC ID K6610334720

HANDHELD TRANSCEIVER

by Yaesu Musen Co., Ltd.

Grantee Code: K66   Product Code: 10334720
Latest application date: 2009-11-09

FCC ID Device Details

FCC IDK6610334720
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeK66
Product Code10334720
Applicant BusinessYaesu Musen Co., Ltd. 🇯🇵
Related Domains yaesu.com
Equipment ClassHANDHELD TRANSCEIVER
Test FirmTimco Engineering, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-512 MHzClass II permissive change or modification of presently authorized equipment2009-11-09
450-512 MHzOriginal Equipment2004-12-28

Exhibits

DocumentTypeAvailableFile
USERS MANUALUsers Manual2004-12-28PDF 147.5 KB
INTERNAL PHOTOSInternal Photos2004-12-28PDF 1.7 MB
EXTERNAL PHOTOSExternal Photos2004-12-28PDF 108.3 KB
ID LABEL SAMPLEID Label/Location Info2004-12-28PDF 30.4 KB
OPERATIONAL DESCRIPTIONOperational Description2004-12-28PDF 70.9 KB
Test ReportTest Report2009-11-09PDF 211.8 KB
TEST REPORTTest Report2004-12-28PDF 398.8 KB
Cover LetterCover Letter(s)2009-11-09PDF 50.7 KB
CONFIDENTIALITY LETTERCover Letter(s)2004-12-28PDF 98.8 KB
PARTS LISTParts List/Tune Up Info2004-12-28PDF 42 KB
SAR REPORTRF Exposure Info2004-12-28PDF 3 MB
BLOCK DIAGRAM Metadata onlyBlock DiagramPDF 581.5 KB
SCHEMATICS Metadata onlySchematicsPDF 1.9 MB

Application Information

Application IDTZskf0rAcvFM+PUyO+968A==
Final Action Date2009-11-09
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0013655220
Model10334720
Frequency Range450-512 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionHANDHELD TRANSCEIVER
Responsible PartyKouji Taguchi, Engineering Division/Quality Assurance Leader, k.taguchi@yaesu.com , 81-3-6711-4121
Test FirmSid Sanders, Timco Engineering, Inc., tei@timcoengr.com , 352-472-5500
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput is conducted and variable between the limits shown. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Body-worn SAR compliance is limited to the specific belt-clip tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 1.96 W/kg at a 50% duty factor; Body: 4.89 W/kg, at a 50% duty factor. (Orig. Grant: 12/28/2004) Class II Permissive Change: This Class II Change adds output power continuously variable between 0.25 Watts and the listed power of 5.0 Watts..

Applications

Application IDDatePurpose
TZskf0rAcvFM+PUyO+968A==2009-11-09Class II permissive change or modification of presently authorized equipment
tHjfaJMs7ByaQ88IFgSkrQ==2004-12-28Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
450-512 MHz52.5ppm16K0F3E22, 74, 90, 95A
450-512 MHz12.5ppm16K0F3E22, 74, 90, 95A
450-512 MHz52.5ppm11K0F3E22, 74, 90, 95A
450-512 MHz12.5ppm11K0F3E22, 74, 90, 95A

Grants

TCB Grant - Application TZskf0rAcvFM+PUyO+968A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 11/09/2009

Application Dated: 11/09/2009
Yaesu Musen Co., Ltd.
Tennozu Parkside Building
2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
 
Attention: Kouji Taguchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K6610334720
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: HANDHELD TRANSCEIVER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22, 74, 90, 95A 450.0  -  512.0 5.0 2.5  PM 16K0F3E
22, 74, 90, 95A 450.0  -  512.0 1.0 2.5  PM 16K0F3E
22, 74, 90, 95A 450.0  -  512.0 5.0 2.5  PM 11K0F3E
22, 74, 90, 95A 450.0  -  512.0 1.0 2.5  PM 11K0F3E

Output is conducted and variable between the limits shown. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Body-worn SAR compliance is limited to the specific belt-clip tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 1.96 W/kg at a 50% duty factor; Body: 4.89 W/kg, at a 50% duty factor. (Orig. Grant: 12/28/2004)

Class II Permissive Change: This Class II Change adds output power continuously variable between 0.25 Watts and the listed power of 5.0 Watts..


EAS Grant - Application TZskf0rAcvFM+PUyO+968A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Yaesu Musen Co., Ltd.
Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
  Date of Grant: 11/09/2009

Application Dated: 11/09/2009
 
Attention: Kouji Taguchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K6610334720
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: HANDHELD TRANSCEIVER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22, 74, 90, 95A 450.0  -  512.0 5.0 2.5  PM 16K0F3E
22, 74, 90, 95A 450.0  -  512.0 1.0 2.5  PM 16K0F3E
22, 74, 90, 95A 450.0  -  512.0 5.0 2.5  PM 11K0F3E
22, 74, 90, 95A 450.0  -  512.0 1.0 2.5  PM 11K0F3E

Output is conducted and variable between the limits shown. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Body-worn SAR compliance is limited to the specific belt-clip tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 1.96 W/kg at a 50% duty factor; Body: 4.89 W/kg, at a 50% duty factor. (Orig. Grant: 12/28/2004)

Class II Permissive Change: This Class II Change adds output power continuously variable between 0.25 Watts and the listed power of 5.0 Watts..



TCB Grant - Application tHjfaJMs7ByaQ88IFgSkrQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 12/28/2004

Application Dated: 12/28/2004
Yaesu Musen Co., Ltd.
Tennozu Parkside Building
2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
 
Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K6610334720
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: HANDHELD TRANSCEIVER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22, 74, 90, 95A 450.0  -  512.0 5.0 2.5  PM 16K0F3E
22, 74, 90, 95A 450.0  -  512.0 1.0 2.5  PM 16K0F3E
22, 74, 90, 95A 450.0  -  512.0 5.0 2.5  PM 11K0F3E
22, 74, 90, 95A 450.0  -  512.0 1.0 2.5  PM 11K0F3E

Output is conducted and variable between the limits shown. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Body-worn SAR compliance is limited to the specific belt-clip tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 1.96 W/kg at a 50% duty factor; Body: 4.89 W/kg, at a 50% duty factor.

EAS Grant - Application tHjfaJMs7ByaQ88IFgSkrQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Yaesu Musen Co., Ltd.
Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
  Date of Grant: 12/28/2004

Application Dated: 12/28/2004
 
Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K6610334720
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: HANDHELD TRANSCEIVER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22, 74, 90, 95A 450.0  -  512.0 5.0 2.5  PM 16K0F3E
22, 74, 90, 95A 450.0  -  512.0 1.0 2.5  PM 16K0F3E
22, 74, 90, 95A 450.0  -  512.0 5.0 2.5  PM 11K0F3E
22, 74, 90, 95A 450.0  -  512.0 1.0 2.5  PM 11K0F3E

Output is conducted and variable between the limits shown. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Body-worn SAR compliance is limited to the specific belt-clip tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 1.96 W/kg at a 50% duty factor; Body: 4.89 W/kg, at a 50% duty factor.