FCC ID K6610614740
MOBILE TWO-WAY RADIO
by Yaesu Musen Co., Ltd.
Grantee Code: K66 Product Code: 10614740
Latest application date: 2006-06-08
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 450-512 MHz | Original Equipment | 2006-06-08 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| users manual | Users Manual | 2006-06-08 | PDF 697.2 KB |
| internal photos | Internal Photos | 2006-06-08 | PDF 1,017.3 KB |
| external photos | External Photos | 2006-06-08 | PDF 357.1 KB |
| label sample | ID Label/Location Info | 2006-06-08 | PDF 138.9 KB |
| operational description | Operational Description | 2006-06-08 | PDF 101 KB |
| test report | Test Report | 2006-06-08 | PDF 399.7 KB |
| compliance statement 1 of 3 | Attestation Statements | 2006-06-08 | PDF 50.1 KB |
| compliance statement 3 of 3 | Attestation Statements | 2006-06-08 | PDF 51.7 KB |
| complinace statement 2 of 3 | Attestation Statements | 2006-06-08 | PDF 53.3 KB |
| compliance statement 2 of 3 Metadata only | Cover Letter(s) | 2006-06-08 | PDF 53.3 KB |
| confidentiality letter | Cover Letter(s) | 2006-06-08 | PDF 72.7 KB |
| parts list | Parts List/Tune Up Info | 2006-06-08 | PDF 39.8 KB |
| rf exposure | RF Exposure Info | 2006-06-08 | PDF 49.2 KB |
| tune up procedure | Parts List/Tune Up Info | 2006-06-08 | PDF 167.8 KB |
| block diagram Metadata only | Block Diagram | PDF 336.2 KB | |
| schematics 1 of 3 Metadata only | Schematics | PDF 95.5 KB | |
| schematics 2 of 3 Metadata only | Schematics | PDF 174.7 KB | |
| schematics 3 of 3 Metadata only | Schematics | PDF 1.3 MB |
Application Information
| Application ID | kb9rNU1tFclen4jH7qGh5Q== |
|---|---|
| Final Action Date | 2006-06-08 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0013655220 |
| Model | 10614740 |
| Frequency Range | 450-512 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | MOBILE TWO-WAY RADIO |
| Responsible Party | Tetsuya Masubuchi, Engineering Division/Quality Assurance Leader, t.masubuchi@yaesu.com |
| Test Firm | Sid Sanders, Timco Engineering, Inc., info@timcoengr.com |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 44cm from all persons and must not exceed an antenna gain of 0 dBd. Output Power is variable between the two values shown in this filing. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| kb9rNU1tFclen4jH7qGh5Q== | 2006-06-08 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application kb9rNU1tFclen4jH7qGh5Q==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 06/08/2006 Application Dated: 06/08/2006 |
| Yaesu Musen Co., Ltd. |
| Tennozu Parkside Building |
| 2-5-8 Higashi-Shinagawa, Shinagawa-ku |
| Tokyo, 140-0002 Japan |
| Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | K6610614740 |
| Name of Grantee: | Yaesu Musen Co., Ltd. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | MOBILE TWO-WAY RADIO |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.0 - 512.0 | 45.0 | 2.5 PM | 16K0F3E | |
| 90 | 450.0 - 512.0 | 10.0 | 2.5 PM | 16K0F3E | |
| 90 | 450.0 - 512.0 | 45.0 | 2.5 PM | 11K0F3E | |
| 90 | 450.0 - 512.0 | 10.0 | 2.5 PM | 11K0F3E |
| Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 44cm from all persons and must not exceed an antenna gain of 0 dBd. Output Power is variable between the two values shown in this filing. |
EAS Grant - Application kb9rNU1tFclen4jH7qGh5Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Yaesu Musen Co., Ltd. Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku Tokyo, 140-0002 Japan |
Date of Grant: 06/08/2006 Application Dated: 06/08/2006 |
| Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | K6610614740 |
| Name of Grantee: | Yaesu Musen Co., Ltd. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | MOBILE TWO-WAY RADIO |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.0 - 512.0 | 45.0 | 2.5 PM | 16K0F3E | |
| 90 | 450.0 - 512.0 | 10.0 | 2.5 PM | 16K0F3E | |
| 90 | 450.0 - 512.0 | 45.0 | 2.5 PM | 11K0F3E | |
| 90 | 450.0 - 512.0 | 10.0 | 2.5 PM | 11K0F3E |
| Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 44cm from all persons and must not exceed an antenna gain of 0 dBd. Output Power is variable between the two values shown in this filing. |
| Mail To: |