FCC ID K6610623X20

Portable Transceiver

by Yaesu Musen Co., Ltd.

Grantee Code: K66   Product Code: 10623X20
Latest application date: 2005-01-27

FCC ID Device Details

FCC IDK6610623X20
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeK66
Product Code10623X20
Applicant BusinessYaesu Musen Co., Ltd. 🇯🇵
Related Domains yaesu.com
Equipment ClassPortable Transceiver
Test FirmTimco Engineering, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
118-136.975 MHzOriginal Equipment2005-01-27

Exhibits

DocumentTypeAvailableFile
USERS MANUALUsers Manual2005-01-27PDF 228 KB
INTERNAL PHOTOSInternal Photos2005-01-27PDF 532.4 KB
EXTERNAL PHOTOSExternal Photos2005-01-27PDF 539.6 KB
ID LABEL SAMPLE AND LOCATIONID Label/Location Info2005-01-27PDF 1 MB
OPERATIONAL DESCRIPTIONOperational Description2005-01-27PDF 99.5 KB
TEST REPORTTest Report2005-01-27PDF 294.7 KB
CONFIDENTIALITY LETTRCover Letter(s)2005-01-27PDF 110.6 KB
PARTS LISTParts List/Tune Up Info2005-01-27PDF 39.5 KB
TUNE UPParts List/Tune Up Info2005-01-27PDF 123 KB
BLOCK DIAGRAM Metadata onlyBlock DiagramPDF 547.1 KB
SCHEMATICS Metadata onlySchematicsPDF 1.9 MB

Application Information

Application IDb0hbE3vad+6RP6U2pgLpwA==
Final Action Date2005-01-27
Application PurposeOriginal Equipment
Applicant FRN0013655220
Model10623X20
Frequency Range118-136.975 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionPortable Transceiver
Responsible PartyTetsuya Masubuchi, Engineering Division/Quality Assurance Leader, t.masubuchi@yaesu.com , 81-3-6711-4121
Test FirmS Sanders, Timco Engineering, Inc., info@timcoengr.com , 888-472-2424
TCB Emailtei@timcoengr.com
TCB ScopeB3: Maritime & Aviation Radio Services equipment in 47 CFR parts 80 & 87
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty cycle factor of 50%. End-Users must be provided with the specific training information. A label, as described in this filing, must be displayed on the device to direct users to the specific training information required for meeting RF exposure requirements. All qualified end-users of this device must have the knowledge to control their exposure conditions an/or duration to comply with Occupational/Controlled limit and requirements.

Applications

Application IDDatePurpose
b0hbE3vad+6RP6U2pgLpwA==2005-01-27Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
118-136.975 MHz1.500000020.0000000000ppm6K00A3E87

Grants

TCB Grant - Application b0hbE3vad+6RP6U2pgLpwA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 01/27/2005

Application Dated: 01/27/2005
Yaesu Musen Co., Ltd.
Tennozu Parkside Building
2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
 
Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K6610623X20
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Portable Transceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
87 118.0  -  136.975 1.5 20.0  PM 6K00A3E

Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty cycle factor of 50%. End-Users must be provided with the specific training information. A label, as described in this filing, must be displayed on the device to direct users to the specific training information required for meeting RF exposure requirements. All qualified end-users of this device must have the knowledge to control their exposure conditions an/or duration to comply with Occupational/Controlled limit and requirements.

EAS Grant - Application b0hbE3vad+6RP6U2pgLpwA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Yaesu Musen Co., Ltd.
Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
  Date of Grant: 01/27/2005

Application Dated: 01/27/2005
 
Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K6610623X20
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Portable Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
87 118.0  -  136.975 1.5 20.0  PM 6K00A3E

Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty cycle factor of 50%. End-Users must be provided with the specific training information. A label, as described in this filing, must be displayed on the device to direct users to the specific training information required for meeting RF exposure requirements. All qualified end-users of this device must have the knowledge to control their exposure conditions an/or duration to comply with Occupational/Controlled limit and requirements.



Mail To: