FCC ID K6611033040
VHF TRANSCEIVER/REPEATER
by Yaesu Musen Co., Ltd.
Grantee Code: K66 Product Code: 11033040
Latest application date: 2011-04-14
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 150-174 MHz | Change in identification of presently authorized equipment. Original FCC ID: ABZ99FT3025 Grant Date: 05/22/2007 | 2011-04-14 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| EXTERNAL PHOTOS | External Photos | 2011-04-14 | PDF 230.9 KB |
| LABEL | ID Label/Location Info | 2011-04-14 | PDF 658.7 KB |
| AUTHORIZATION LETTER | Cover Letter(s) | 2011-04-14 | PDF 45.8 KB |
| COVER LETTER | Cover Letter(s) | 2011-04-14 | PDF 51.2 KB |
Application Information
| Application ID | j6VOmeEOtpWlDUxfYccdrA== |
|---|---|
| Final Action Date | 2011-04-14 |
| Application Purpose | Change in identification of presently authorized equipment. Original FCC ID: ABZ99FT3025 Grant Date: 05/22/2007 |
| Applicant FRN | 0013655220 |
| Model | 11033040 |
| Frequency Range | 150-174 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | VHF TRANSCEIVER/REPEATER |
| Responsible Party | Kouji Taguchi, Engineering Division/Quality Assurance Leader, k.taguchi@yaesu.com |
| Test Firm | Sid Sanders, Timco Engineering, Inc., tei@timcoengr.com |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). Wideband disabled. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| j6VOmeEOtpWlDUxfYccdrA== | 2011-04-14 | Change in identification of presently authorized equipment. Original FCC ID: ABZ99FT3025 Grant Date: 05/22/2007 |
Equipment Authorization
Grants
TCB Grant - Application j6VOmeEOtpWlDUxfYccdrA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 <BR>P.O. Box 370, Newberry, FL 32669 |
Date of Grant: 04/14/2011 Application Dated: 04/14/2011 |
| Yaesu Musen Co., Ltd. |
| Tennozu Parkside Building |
| 2-5-8 Higashi-Shinagawa, Shinagawa-ku |
| Tokyo, 140-0002 Japan |
| Attention: Kouji Taguchi , Engineering Division/Quality Assurance Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | K6611033040 |
| Name of Grantee: | Yaesu Musen Co., Ltd. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | VHF TRANSCEIVER/REPEATER |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BM | 90, 90.210 | 150.0 - 174.0 | 48.0 | 1.5 PM | 11K0F3E |
| BM | 90, 90.210 | 150.0 - 174.0 | 48.0 | 1.5 PM | 7K60FXD |
| BM | 90, 90.210 | 150.0 - 174.0 | 48.0 | 1.5 PM | 4K60FXE |
| The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). Wideband disabled. |
| BM: | The output power is continuously variable from the value listed in this entry to 50%-55% of the value listed. |
EAS Grant - Application j6VOmeEOtpWlDUxfYccdrA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Yaesu Musen Co., Ltd. Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku Tokyo, 140-0002 Japan |
Date of Grant: 04/14/2011 Application Dated: 04/14/2011 |
| Attention: Kouji Taguchi , Engineering Division/Quality Assurance Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | K6611033040 |
| Name of Grantee: | Yaesu Musen Co., Ltd. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | VHF TRANSCEIVER/REPEATER |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BM | 90, 90.210 | 150.0 - 174.0 | 48.0 | 1.5 PM | 11K0F3E |
| BM | 90, 90.210 | 150.0 - 174.0 | 48.0 | 1.5 PM | 7K60FXD |
| BM | 90, 90.210 | 150.0 - 174.0 | 48.0 | 1.5 PM | 4K60FXE |
| The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). Wideband disabled. |
| BM: | The output power is continuously variable from the value listed in this entry to 50%-55% of the value listed. |
| Mail To: |