FCC ID K66VX-900U

VX-900U

by Yaesu Musen Co., Ltd.

Grantee Code: K66   Product Code: VX900U
Latest application date: 2001-07-06

FCC ID Device Details

FCC IDK66VX-900U
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeK66
Product CodeVX900U
Applicant BusinessYaesu Musen Co., Ltd. 🇯🇵
Related Domains yaesu.com
Equipment ClassVX-900U
Test FirmRhein Tech Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-489.95 MHzClass II permissive change or modification of presently authorized equipment2001-07-06
450-485 MHzOriginal Equipment2001-03-02

Exhibits

DocumentTypeAvailableFile
NEW ManualUsers Manual2001-03-02PDF 303.4 KB
Operator ManualUsers Manual2001-03-02PDF 295 KB
manualUsers Manual2001-03-02PDF 281.4 KB
Internal PicturesInternal Photos2001-03-02PDF 853.9 KB
External PicturesExternal Photos2001-03-02PDF 886.1 KB
labelID Label/Location Info2001-03-02PDF 392.9 KB
Test ReportTest Report2001-07-06PDF 932.9 KB
reportTest Report2001-03-02PDF 888.8 KB
Agent AuthorCover Letter(s)2001-07-06PDF 315.7 KB
Original GrantCover Letter(s)2001-07-06PDF 7.8 KB
Agency letterCover Letter(s)2001-03-02PDF 315.7 KB
Answer to correspondenceCover Letter(s)2001-03-02PDF 22 KB
Confidential LetterCover Letter(s)2001-03-02PDF 141.2 KB
Mfg letterCover Letter(s)2001-03-02PDF 364.3 KB
answer correspondenceCover Letter(s)2001-03-02PDF 8.7 KB
Caution labelRF Exposure Info2001-03-02PDF 74.1 KB
Picture of case 2 (withdrawn) Metadata onlyRF Exposure Info2001-03-02PDF 134 KB
Picture of case 3 (withdrawn) Metadata onlyRF Exposure Info2001-03-02PDF 273.5 KB
SAR ReportRF Exposure Info2001-03-02PDF 3.7 MB
SAR Report (Note: leather case withdrawn by applicant)RF Exposure Info2001-03-02PDF 3.7 MB
Warning labelRF Exposure Info2001-03-02PDF 161.3 KB
Warning photoRF Exposure Info2001-03-02PDF 288.3 KB
parts listParts List/Tune Up Info2001-03-02PDF 20 KB
picture of case (withdrawn) Metadata onlyRF Exposure Info2001-03-02PDF 263.7 KB
warning labelRF Exposure Info2001-03-02PDF 161.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 861.2 KB
Schematics Metadata onlySchematicsPDF 2.3 MB
PD Metadata onlyOperational DescriptionPDF 108.5 KB

Application Information

Application ID647bHpXfT8aJTmDcO2TqwQ==
Final Action Date2001-07-06
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0013655220
ModelVX-900U
Frequency Range450-489.95 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionVX-900U
Responsible PartyTetsuya Masubuchi, Engineering Division/Quality Assurance Leader, t.masubuchi@yaesu.com , 81-3-6711-4121
AgentDesmond Desmond Desmond, Rhein Tech Laboratories, Inc., desmond@rheintech.com , 703 689 0368
Technical ContactDesmond Fraser, Rhein Tech laboratories, Inc., desmond@rheintech.com , 703 689 0368
Test FirmRick McMurray, Rhein Tech Laboratories, Inc., FCCINFO@rheintech.com , 703-689-0368
TCB Emailhotline@americanTCB.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is Conducted. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Body-worn SAR compliance is limited to the specific belt-clip tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 3.09 W/kg; Body-worn: 5.60 W/kg, both tested at 50% duty factor.

Applications

Application IDDatePurpose
647bHpXfT8aJTmDcO2TqwQ==2001-07-06Class II permissive change or modification of presently authorized equipment
jyPaLJRFzSEDwW4D8CWZgQ==2001-03-02Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
450-489.95 MHz52.1ppm11K0F3E90.21
450-485 MHz52.1ppm11K0F3E90.21
450-489.95 MHz52.1ppm16K0F3E22, 74, 90, 95A
450-485 MHz52.1ppm16K0F3E90, 22, 74, 95
450-489.95 MHz2.52.1ppm11K0F3E90.21
450-485 MHz2.52.1ppm11K0F3E90.21
450-489.95 MHz2.52.1ppm16K0F3E22, 74, 90, 95A
450-485 MHz2.52.1ppm16K0F3E90, 22, 74, 95
450-489.95 MHz12.1ppm11K0F3E90.21
450-485 MHz12.1ppm11K0F3E90.21
450-489.95 MHz12.1ppm16K0F3E22, 74, 90, 95A
450-485 MHz12.1ppm16K0F3E90, 22, 74, 95
450-489.95 MHz0.252.1ppm11K0F3E90.21
450-485 MHz0.252.1ppm11K0F3E90.21
450-489.95 MHz0.252.1ppm16K0F3E22, 74, 90, 95A
450-485 MHz0.252.1ppm16K0F3E90, 22, 74, 95

Grants

TCB Grant - Application jyPaLJRFzSEDwW4D8CWZgQ==

This application does not exist.

EAS Grant - Application jyPaLJRFzSEDwW4D8CWZgQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Yaesu Musen Co., Ltd.
Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
  Date of Grant: 03/02/2001

Application Dated: 12/08/2000
 
Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K66VX-900U
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: VX-900U
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.210 450.0  -  485.0 5.0 2.1  PM 11K0F3E
22, 74, 90, 95 450.0  -  485.0 5.0 2.1  PM 16K0F3E
90.210 450.0  -  485.0 2.5 2.1  PM 11K0F3E
22, 74, 90, 95 450.0  -  485.0 2.5 2.1  PM 16K0F3E
90.210 450.0  -  485.0 1.0 2.1  PM 11K0F3E
22, 74, 90, 95 450.0  -  485.0 1.0 2.1  PM 16K0F3E
90.210 450.0  -  485.0 0.25 2.1  PM 11K0F3E
22, 74, 90, 95 450.0  -  485.0 0.25 2.1  PM 16K0F3E

Output is conducted. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Body-worn SAR compliance is limited to the specific belt-clip tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 3.09 W/kg; Body-worn: 5.60 W/kg, both tested at 50% duty factor.



TCB Grant - Application 647bHpXfT8aJTmDcO2TqwQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 07/06/2001

Application Dated: 07/06/2001
Yaesu Musen Co., Ltd.
Tennozu Parkside Building
2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
 
Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K66VX-900U
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: VX-900U
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.210 450.0  -  489.95 5.0 2.1  PM 11K0F3E
22, 74, 90, 95A 450.0  -  489.95 5.0 2.1  PM 16K0F3E
90.210 450.0  -  489.95 2.5 2.1  PM 11K0F3E
22, 74, 90, 95A 450.0  -  489.95 2.5 2.1  PM 16K0F3E
90.210 450.0  -  489.95 1.0 2.1  PM 11K0F3E
22, 74, 90, 95A 450.0  -  489.95 1.0 2.1  PM 16K0F3E
90.210 450.0  -  489.95 0.25 2.1  PM 11K0F3E
22, 74, 90, 95A 450.0  -  489.95 0.25 2.1  PM 16K0F3E

Power Output listed is Conducted. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Body-worn SAR compliance is limited to the specific belt-clip tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 3.09 W/kg; Body-worn: 5.60 W/kg, both tested at 50% duty factor.

EAS Grant - Application 647bHpXfT8aJTmDcO2TqwQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Yaesu Musen Co., Ltd.
Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
  Date of Grant: 07/06/2001

Application Dated: 07/06/2001
 
Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K66VX-900U
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: VX-900U
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.210 450.0  -  489.95 5.0 2.1  PM 11K0F3E
22, 74, 90, 95A 450.0  -  489.95 5.0 2.1  PM 16K0F3E
90.210 450.0  -  489.95 2.5 2.1  PM 11K0F3E
22, 74, 90, 95A 450.0  -  489.95 2.5 2.1  PM 16K0F3E
90.210 450.0  -  489.95 1.0 2.1  PM 11K0F3E
22, 74, 90, 95A 450.0  -  489.95 1.0 2.1  PM 16K0F3E
90.210 450.0  -  489.95 0.25 2.1  PM 11K0F3E
22, 74, 90, 95A 450.0  -  489.95 0.25 2.1  PM 16K0F3E

Power Output listed is Conducted. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Body-worn SAR compliance is limited to the specific belt-clip tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 3.09 W/kg; Body-worn: 5.60 W/kg, both tested at 50% duty factor.



Mail To: