FCC ID K66VX-900V

VX-900V

by Yaesu Musen Co., Ltd.

Grantee Code: K66   Product Code: VX900V
Latest application date: 2001-03-28

FCC ID Device Details

FCC IDK66VX-900V
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeK66
Product CodeVX900V
Applicant BusinessYaesu Musen Co., Ltd. 🇯🇵
Related Domains yaesu.com rheintech.com
Equipment ClassVX-900V

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
148-174 MHzOriginal Equipment2001-03-28

Exhibits

DocumentTypeAvailableFile
Corrected ManualUsers Manual2001-03-28PDF 280.3 KB
Corrected page in manualRF Exposure Info2001-03-28PDF 16.1 KB
Manual Accessory pageRF Exposure Info2001-03-28PDF 9.2 KB
Manual Revision 3RF Exposure Info2001-03-28PDF 302.6 KB
Manual1Users Manual2001-03-28PDF 88.8 KB
Manual2Users Manual2001-03-28PDF 93 KB
InternalInternal Photos2001-03-28PDF 725.8 KB
ExternalExternal Photos2001-03-28PDF 426.9 KB
External Mic and BatteryExternal Photos2001-03-28PDF 499.4 KB
Corrected labelID Label/Location Info2001-03-28PDF 142.7 KB
LabelID Label/Location Info2001-03-28PDF 71 KB
Label2ID Label/Location Info2001-03-28PDF 142.9 KB
Product Description1Operational Description2001-03-28PDF 71.5 KB
Product Description2Operational Description2001-03-28PDF 43.8 KB
ReportTest Report2001-03-28PDF 1.5 MB
Answer letterCover Letter(s)2001-03-28PDF 22.5 KB
Confidential letterCover Letter(s)2001-03-28PDF 107.9 KB
Part 90 letterCover Letter(s)2001-03-28PDF 139.7 KB
Caution LabelRF Exposure Info2001-03-28PDF 74.1 KB
Celltechs Response to CRN17884RF Exposure Info2001-03-28PDF 1 MB
Parts ListParts List/Tune Up Info2001-03-28PDF 19.4 KB
SAR ReportRF Exposure Info2001-03-28PDF 2.7 MB
Block Diagram Metadata onlyBlock DiagramPDF 743.5 KB
Schematic1 Metadata onlySchematicsPDF 131.2 KB
Schematic2 Metadata onlySchematicsPDF 2.4 MB
Schematic3 Metadata onlySchematicsPDF 94.4 KB
Schematic4 Metadata onlySchematicsPDF 43.6 KB

Application Information

Application IDa1ayOkTJxtnPpeTXYeNbgw==
Final Action Date2001-03-28
Application PurposeOriginal Equipment
Applicant FRN0013655220
ModelVX-900V
Frequency Range148-174 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionVX-900V
Responsible PartyTetsuya Masubuchi, Engineering Division/Quality Assurance Leader, t.masubuchi@yaesu.com , 81-3-6711-4121
Technical ContactDesmond A Fraser, Rhein Tech Laboratories, Inc., desmond@rheintech.com , 703-689-0368
Non-Technical ContactMelissa Fleming, Rhein Tech Laboratories, Inc., mfleming@rheintech.com , 703-689-0368
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is ERP. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Body-worn SAR compliance is limited to the specific belt-clip tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 0.98 W/kg; Body-worn: 3.06 W/kg, both tested at 100% duty factor.

Applications

Application IDDatePurpose
a1ayOkTJxtnPpeTXYeNbgw==2001-03-28Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
148-174 MHz52.5ppm11K0F3E90.21
148-174 MHz52.5ppm16K0F3E22, 74, 9
148-174 MHz2.52.5ppm11K0F3E90.21
148-174 MHz2.52.5ppm16K0F3E22, 74, 9
148-174 MHz12.5ppm11K0F3E90.21
148-174 MHz12.5ppm16K0F3E22, 74, 9
148-174 MHz0.252.5ppm11K0F3E90.21
148-174 MHz0.252.5ppm16K0F3E22, 74, 9

Grants

TCB Grant - Application a1ayOkTJxtnPpeTXYeNbgw==

This application does not exist.

EAS Grant - Application a1ayOkTJxtnPpeTXYeNbgw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Yaesu Musen Co., Ltd.
Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
  Date of Grant: 03/28/2001

Application Dated: 12/12/2000
 
Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K66VX-900V
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: VX-900V
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.210 148.0  -  174.0 5.0 2.5  PM 11K0F3E
22, 74, 90 148.0  -  174.0 5.0 2.5  PM 16K0F3E
90.210 148.0  -  174.0 2.5 2.5  PM 11K0F3E
22, 74, 90 148.0  -  174.0 2.5 2.5  PM 16K0F3E
90.210 148.0  -  174.0 1.0 2.5  PM 11K0F3E
22, 74, 90 148.0  -  174.0 1.0 2.5  PM 16K0F3E
90.210 148.0  -  174.0 0.25 2.5  PM 11K0F3E
22, 74, 90 148.0  -  174.0 0.25 2.5  PM 16K0F3E

Power output listed is ERP. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Body-worn SAR compliance is limited to the specific belt-clip tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 0.98 W/kg; Body-worn: 3.06 W/kg, both tested at 100% duty factor.