FCC ID K66VXR-7000U-2

Non-Broadcast UHF-FM Fixed Base Station

by Yaesu Musen Co., Ltd.

Grantee Code: K66   Product Code: VXR7000U2
Latest application date: 2000-12-04

FCC ID Device Details

FCC IDK66VXR-7000U-2
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeK66
Product CodeVXR7000U2
Applicant BusinessYaesu Musen Co., Ltd. 🇯🇵
Related Domains yaesu.com
Equipment ClassNon-Broadcast UHF-FM Fixed Base Station
Test FirmRhein Tech Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
400-430 MHzOriginal Equipment2000-12-04

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2000-12-04PDF 1 MB
Internal PhotosInternal Photos2000-12-04PDF 3.5 MB
Exyernal PhotosExternal Photos2000-12-04PDF 767.8 KB
Label StatementID Label/Location Info2000-12-04PDF 84.3 KB
Label and LocationID Label/Location Info2000-12-04PDF 666.5 KB
Block DiagramBlock Diagram2000-12-04PDF 691.7 KB
All SchematicsSchematics2000-12-04PDF 3.7 MB
RF SchematicsSchematics2000-12-04PDF 1.6 MB
Ckt DescriptionOperational Description2000-12-04PDF 61.2 KB
EmissionsTest Report2000-12-04PDF 4.5 KB
Test ReportTest Report2000-12-04PDF 1 MB
Programming AttestationAttestation Statements2000-12-04PDF 77.3 KB
Specs by ApplicantCover Letter(s)2000-12-04PDF 37 KB
Active PartsParts List/Tune Up Info2000-12-04PDF 43.3 KB
AlignmentParts List/Tune Up Info2000-12-04PDF 73.6 KB
RF ExposureRF Exposure Info2000-12-04PDF 10.8 KB

Application Information

Application IDf1Kbp+BVpHBu5xKAUqfmqg==
Final Action Date2000-12-04
Application PurposeOriginal Equipment
Applicant FRN0013655220
ModelVXR-7000U-2
Frequency Range400-430 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionNon-Broadcast UHF-FM Fixed Base Station
Responsible PartyTetsuya Masubuchi, Engineering Division/Quality Assurance Leader, t.masubuchi@yaesu.com , 81-3-6711-4121
AgentDesmond Desmond Desmond, Rhein Tech Laboratories, Inc., desmond@rheintech.com , 703 689 0368
Technical ContactDesmond Fraser, Rhein Tech Laboratories, Inc., desmond@rheintech.com , 703 689 0368
Test FirmRick McMurray, Rhein Tech Laboratories, Inc., FCCINFO@rheintech.com , 703-689-0368
TCB Emailhotline@americantcb.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsThe antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 54.5W and the peak radiated output power must not exceed 360W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
f1Kbp+BVpHBu5xKAUqfmqg==2000-12-04Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
400-430 MHz501.5ppm16K0F3E9BF
400-430 MHz501.5ppm11K0F3E90.21BF

Grants

TCB Grant - Application f1Kbp+BVpHBu5xKAUqfmqg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 12/04/2000

Application Dated: 12/04/2000
Yaesu Musen Co., Ltd.
Tennozu Parkside Building
2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
 
Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K66VXR-7000U-2
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Non-Broadcast UHF-FM Fixed Base Station
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BF 90 400.0  -  430.0 50.0 1.5  PM 16K0F3E
BF 90.210 400.0  -  430.0 50.0 1.5  PM 11K0F3E

The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 54.5W and the peak radiated output power must not exceed 360W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance.

BF: The output power is continuously variable from the value listed in this entry to 20%-25% of the value listed.

EAS Grant - Application f1Kbp+BVpHBu5xKAUqfmqg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Yaesu Musen Co., Ltd.
Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
  Date of Grant: 12/04/2000

Application Dated: 12/04/2000
 
Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K66VXR-7000U-2
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Non-Broadcast UHF-FM Fixed Base Station
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BF 90 400.0  -  430.0 50.0 1.5  PM 16K0F3E
BF 90.210 400.0  -  430.0 50.0 1.5  PM 11K0F3E

The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 54.5W and the peak radiated output power must not exceed 360W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance.


BF: The output power is continuously variable from the value listed in this entry to 20%-25% of the value listed.