FCC ID KA2WA130A1

Wireless N USB Adapter

by D-Link Corporation

Grantee Code: KA2   Product Code: WA130A1
Latest application date: 2007-03-30

FCC ID Device Details

FCC IDKA2WA130A1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeKA2
Product CodeWA130A1
Applicant BusinessD-Link Corporation 🇺🇸
Related Domains dlink.com
Equipment ClassWireless N USB Adapter
Test FirmSporton International Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzChange in identification of presently authorized equipment. Original FCC ID: NHPWLN1501 Grant Date: 03/27/20072007-03-30

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2007-03-30PDF 344.6 KB
Label InfoID Label/Location Info2007-03-30PDF 106.9 KB
ID Change LetterCover Letter(s)2007-03-30PDF 18.6 KB

Application Information

Application ID18XGXdau1WVEi6lGZU777A==
Final Action Date2007-03-30
Application PurposeChange in identification of presently authorized equipment. Original FCC ID: NHPWLN1501 Grant Date: 03/27/2007
Applicant FRN0006207146
ModelWA130A1
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWireless N USB Adapter
Responsible PartyMichael Boschma, Engineer, MBoschma@dlink.com , 714-885-6105
Technical ContactWayne Hsu, Sporton International Inc., wayne@sporton.com.tw
Test FirmW Huang, Sporton International Inc., kathy@sporton.com.tw , 886-2-2696-2468
TCB Emailbentje.holger@phoenix-testlab.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is the maximum combined conducted output power asindicated in the filing. Device is operating in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest SAR value for this device as reported to the FCC is: Body; 0.778 Watts/kg.

Applications

Application IDDatePurpose
18XGXdau1WVEi6lGZU777A==2007-03-30Change in identification of presently authorized equipment. Original FCC ID: NHPWLN1501 Grant Date: 03/27/2007

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.103800015CMO

Grants

TCB Grant - Application 18XGXdau1WVEi6lGZU777A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 03/30/2007

Application Dated: 03/30/2007
D Link Corporation
17595 Mt. Herrmann
Fountain Valley, CA 92708
 
Attention: Michael Boschma , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  KA2WA130A1
Name of Grantee:  D Link Corporation
Equipment Class: Digital Transmission System
Notes: Wireless N USB Adapter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15C 2412.0  -  2462.0 0.1038  

Power listed is the maximum combined conducted output power asindicated in the filing. Device is operating in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest SAR value for this device as reported to the FCC is: Body; 0.778 Watts/kg.

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application 18XGXdau1WVEi6lGZU777A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

D Link Corporation
17595 Mt. Herrmann
Fountain Valley, CA 92708
United States
  Date of Grant: 03/30/2007

Application Dated: 03/30/2007
 
Attention: Michael Boschma , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  KA2WA130A1
Name of Grantee:  D Link Corporation
Equipment Class: Digital Transmission System
Notes: Wireless N USB Adapter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15C 2412.0  -  2462.0 0.1038  

Power listed is the maximum combined conducted output power asindicated in the filing. Device is operating in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest SAR value for this device as reported to the FCC is: Body; 0.778 Watts/kg.


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To:


EA544174