FCC ID KA2WA131A1

Wireless N Nano USB Adapter

by D-Link Corporation

Grantee Code: KA2   Product Code: WA131A1
Latest application date: 2009-06-29

FCC ID Device Details

FCC IDKA2WA131A1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeKA2
Product CodeWA131A1
Applicant BusinessD-Link Corporation 🇺🇸
Related Domains dlink.com adt.com.tw
Equipment ClassWireless N Nano USB Adapter
Test FirmBureau Veritas CPS (H.K.) Ltd. Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2009-06-29

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2009-06-29PDF 2.2 MB
Int photosInternal Photos2009-06-29PDF 356.4 KB
Ext photosExternal Photos2009-06-29PDF 128.4 KB
LabelID Label/Location Info2009-06-29PDF 148.4 KB
Label LocationID Label/Location Info2009-06-29PDF 49.4 KB
OpDescOperational Description2009-06-29PDF 27 KB
Test Setup PhotosTest Setup Photos2009-06-29PDF 209.9 KB
Test ReportTest Report2009-06-29PDF 777 KB
Attestation Ad hoc declarationAttestation Statements2009-06-29PDF 35.8 KB
Confidentiality ReqCover Letter(s)2009-06-29PDF 41.1 KB
Coverletter Contact AuthorizationCover Letter(s)2009-06-29PDF 45.5 KB
Coverletter POACover Letter(s)2009-06-29PDF 37.7 KB
RF Exposure 1RF Exposure Info2009-06-29PDF 1.2 MB
RF Exposure 2RF Exposure Info2009-06-29PDF 2.7 MB
RF Exposure 3RF Exposure Info2009-06-29PDF 2.2 MB

Application Information

Application IDw2eV6bO92wQYiQucVC6cUA==
Final Action Date2009-06-29
Application PurposeOriginal Equipment
Applicant FRN0006207146
ModelWA131A1
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWireless N Nano USB Adapter
Responsible PartyMichael Boschma, Engineer, MBoschma@dlink.com , 714-885-6105
Technical ContactGary Chang, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, Gary_chang@adt.com.tw , 886-3-3183232
Non-Technical ContactEllis Wu, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, ellis@adt.com.tw , 886-3-3183232
Test FirmRichard Chen, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, richard.chen@tw.bureauveritas.com , 886-3-3183232
TCB Emailcertification@curtis-straus.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. Device is a draft 802.11n USB adapter operating in a 1x2 Spatial Multiplexing MIMO configuration as described in this filing. SAR compliance has been established in the laptop computer(s) configurations with USB slot(s) configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The highest reported body SAR value is: 1.01 W/kg.

Applications

Application IDDatePurpose
w2eV6bO92wQYiQucVC6cUA==2009-06-29Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.318000015CMO

Grants

TCB Grant - Application w2eV6bO92wQYiQucVC6cUA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Curtis-Straus LLC
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 06/29/2009

Application Dated: 06/29/2009
D Link Corporation
17595 Mt. Herrmann
Fountain Valley, CA 92708
 
Attention: Michael Boschma , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  KA2WA131A1
Name of Grantee:  D Link Corporation
Equipment Class: Digital Transmission System
Notes: Wireless N Nano USB Adapter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15C 2412.0  -  2462.0 0.318  

Output power listed is conducted. Device is a draft 802.11n USB adapter operating in a 1x2 Spatial Multiplexing MIMO configuration as described in this filing. SAR compliance has been established in the laptop computer(s) configurations with USB slot(s) configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The highest reported body SAR value is: 1.01 W/kg.

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application w2eV6bO92wQYiQucVC6cUA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

D Link Corporation
17595 Mt. Herrmann
Fountain Valley, CA 92708
United States
  Date of Grant: 06/29/2009

Application Dated: 06/29/2009
 
Attention: Michael Boschma , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  KA2WA131A1
Name of Grantee:  D Link Corporation
Equipment Class: Digital Transmission System
Notes: Wireless N Nano USB Adapter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15C 2412.0  -  2462.0 0.318  

Output power listed is conducted. Device is a draft 802.11n USB adapter operating in a 1x2 Spatial Multiplexing MIMO configuration as described in this filing. SAR compliance has been established in the laptop computer(s) configurations with USB slot(s) configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The highest reported body SAR value is: 1.01 W/kg.


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: