FCC ID KBCIX100XAC555

Rugged handheld PC with PCS/cellular CDMA modem

by General Dynamics Itronix Corporation

Grantee Code: KBC   Product Code: IX100XAC555
Latest application date: 2004-09-17

FCC ID Device Details

FCC IDKBCIX100XAC555
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeKBC
Product CodeIX100XAC555
Applicant BusinessGeneral Dynamics Itronix Corporation 🇺🇸
Related Domains gd-itronix.com
Equipment ClassRugged handheld PC with PCS/cellular CDMA modem
Test FirmCelltech Labs Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.7-848.31 MHzOriginal Equipment2004-09-17

Exhibits

DocumentTypeAvailableFile
users manualUsers Manual2004-09-17PDF 244.1 KB
internal photosInternal Photos2004-09-17PDF 598.1 KB
external photosExternal Photos2004-09-17PDF 581 KB
label sample and locationID Label/Location Info2004-09-17PDF 442.6 KB
maxrad vehicle antenna specsOperational Description2004-09-17PDF 157.9 KB
nearson helix antenna specsOperational Description2004-09-17PDF 130.3 KB
test setup photosTest Setup Photos2004-09-17PDF 578.3 KB
sar test reportRF Exposure Info2004-09-17PDF 2.8 MB
test reportTest Report2004-09-17PDF 868.8 KB
cover letterCover Letter(s)2004-09-17PDF 94.4 KB
request for confidentialityCover Letter(s)2004-09-17PDF 101.2 KB
rf exposureRF Exposure Info2004-09-17PDF 142.6 KB
schematics Metadata onlySchematicsPDF 805.1 KB
operational description Metadata onlyOperational DescriptionPDF 86.6 KB
parts list Metadata onlyParts List/Tune Up InfoPDF 60.2 KB
tune up info Metadata onlyParts List/Tune Up InfoPDF 60.3 KB

Application Information

Application IDlJ90hSs3CgPpiFplMuiOjg==
Final Action Date2004-09-17
Application PurposeOriginal Equipment
Applicant FRN0005036744
ModelIX100XAC555
Frequency Range824.7-848.31 MHz
Equipment ClassPCT - PCS Licensed Transmitter worn on body
Device DescriptionRugged handheld PC with PCS/cellular CDMA modem
Responsible PartyRay Garcia, Agency Manager, ray.garcia@gd-itronix.com , 954.846.3350
Test FirmBen Hewson, Celltech Labs Inc., ben.hewson@celltechlabs.com , 250-765-7650
TCB Emailtei@timcoengr.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsUsers and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except as evaluated in this filing. For use in RF exposure portable conditions: Output power listed is: 0.313 W EIRP and 0.338 W ERP respectively. SAR compliance for body-worn operating configurations is limited to the specific belt-clips/holsters/accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR level is: Body-worn: 1.01 W/kg. For use in RF exposure mobile conditions: Output power is 0.078 W EIRP and 0.80 W ERP respectively measured for antenna(s) described in this filing. For vehicle operation, the antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
lJ90hSs3CgPpiFplMuiOjg==2004-09-17Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.7-848.31 MHz0.338300Hz1M25F9W22H
824.7-848.31 MHz0.08300Hz1M25F9W22H
1851.25-1908.75 MHz0.313150Hz1M25F9W24E
1851.25-1908.75 MHz0.078150Hz1M25F9W24E

Grants

TCB Grant - Application lJ90hSs3CgPpiFplMuiOjg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 09/17/2004

Application Dated: 09/17/2004
General Dynamics Itronix Corporation
1000 Sawgrass Corporate Parkway
Suite 300
Sunrise, FL 33323
 
Attention: Ray Garcia , Agency Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  KBCIX100XAC555
Name of Grantee:  General Dynamics Itronix Corporation
Equipment Class: PCS Licensed Transmitter worn on body
Notes: Rugged handheld PC with PCS/cellular CDMA modem
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1851.25  -  1908.75 0.313 150.0  Hz 1M25F9W
24E 1851.25  -  1908.75 0.078 150.0  Hz 1M25F9W
22H 824.7  -  848.31 0.338 300.0  Hz 1M25F9W
22H 824.7  -  848.31 0.08 300.0  Hz 1M25F9W

Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except as evaluated in this filing. For use in RF exposure portable conditions: Output power listed is: 0.313 W EIRP and 0.338 W ERP respectively. SAR compliance for body-worn operating configurations is limited to the specific belt-clips/holsters/accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR level is: Body-worn: 1.01 W/kg. For use in RF exposure mobile conditions: Output power is 0.078 W EIRP and 0.80 W ERP respectively measured for antenna(s) described in this filing. For vehicle operation, the antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application lJ90hSs3CgPpiFplMuiOjg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

General Dynamics Itronix Corporation
1000 Sawgrass Corporate Parkway Suite 300
Sunrise, FL 33323
United States
  Date of Grant: 09/17/2004

Application Dated: 09/17/2004
 
Attention: Ray Garcia , Agency Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  KBCIX100XAC555
Name of Grantee:  General Dynamics Itronix Corporation
Equipment Class: PCS Licensed Transmitter worn on body
Notes: Rugged handheld PC with PCS/cellular CDMA modem
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1851.25  -  1908.75 0.313 150.0  Hz 1M25F9W
24E 1851.25  -  1908.75 0.078 150.0  Hz 1M25F9W
22H 824.7  -  848.31 0.338 300.0  Hz 1M25F9W
22H 824.7  -  848.31 0.08 300.0  Hz 1M25F9W

Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except as evaluated in this filing. For use in RF exposure portable conditions: Output power listed is: 0.313 W EIRP and 0.338 W ERP respectively. SAR compliance for body-worn operating configurations is limited to the specific belt-clips/holsters/accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR level is: Body-worn: 1.01 W/kg. For use in RF exposure mobile conditions: Output power is 0.078 W EIRP and 0.80 W ERP respectively measured for antenna(s) described in this filing. For vehicle operation, the antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: