FCC ID KQGRMM-QE
The Renishaw RMM-QE (Radio Machine Module) is designed to work with the Renishaw USI (Universal Sensor Interface) and is designed to support Renishaw probes that require rich data processing.
by Renishaw plc
Grantee Code: KQG Product Code: RMMQE
Latest application date: 2026-04-02
FCC ID Device Details
| FCC ID | KQGRMM-QE |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | KQG |
| Product Code | RMMQE |
| Applicant Business | Renishaw plc 🇬🇧 |
| Related Domains | |
| Equipment Class | The Renishaw RMM-QE (Radio Machine Module) is designed to work with the Renishaw USI (Universal Sensor Interface) and is designed to support Renishaw probes that require rich data processing. |
| Test Firm | TUV SUD Limited |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2026-04-02 |
| 2402-2480 MHz | Original Equipment | 2026-04-02 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Label | ID Label/Location Info | 2026-04-02 | PDF 239.7 KB |
| 15C Test Report 1 of 2 | Test Report | 2026-04-02 | PDF 5.1 MB |
| 15C Test Report 2 of 2 | Test Report | 2026-04-02 | PDF 3.6 MB |
| Part 15 Antenna Details | Test Report | 2026-04-02 | PDF 541 KB |
| Simultaneous Transmission (Intermod) Emissions | Test Report | 2026-04-02 | PDF 1.6 MB |
| Covered Equipment Attestation | Attestation Statements | 2026-04-02 | PDF 273.8 KB |
| US Agent for Service of Process Attestation | Attestation Statements | 2026-04-02 | PDF 251.2 KB |
| Agent (Power of Attorney) Cover Letter | Cover Letter(s) | 2026-04-02 | PDF 485.2 KB |
| Confidentiality Request Cover Letter | Cover Letter(s) | 2026-04-02 | PDF 207 KB |
| RF Exposure Exemption Report | RF Exposure Info | 2026-04-02 | PDF 375.5 KB |
| User Manual 1 of 2 Metadata only | Users Manual | 2026-09-28 | PDF 2.6 MB |
| User Manual 2 of 2 Metadata only | Users Manual | 2026-09-28 | PDF 1.4 MB |
| Internal Photos 1 of 2 Metadata only | Internal Photos | 2026-09-28 | PDF 2.4 MB |
| Internal Photos 2 of 2 Metadata only | Internal Photos | 2026-09-28 | PDF 139.5 KB |
| External Photos Metadata only | External Photos | 2026-09-28 | PDF 1.6 MB |
| Test Setup Photos Metadata only | Test Setup Photos | 2026-09-28 | PDF 801.2 KB |
| Block Diagram Metadata only | Block Diagram | PDF 106 KB | |
| Schematics Metadata only | Schematics | PDF 987 KB | |
| Operational Description Metadata only | Operational Description | PDF 1.6 MB | |
| Parts List 1 of 2 Metadata only | Parts List/Tune Up Info | PDF 37.7 KB | |
| Parts List 2 of 2 Metadata only | Parts List/Tune Up Info | PDF 201.8 KB |
Application Information
| Application ID | x5cKGDzDabm54S2uUC5AQg== |
|---|---|
| Final Action Date | 2026-04-02 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0007524929 |
| Model | RMM-QE |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | The Renishaw RMM-QE (Radio Machine Module) is designed to work with the Renishaw USI (Universal Sensor Interface) and is designed to support Renishaw probes that require rich data processing. |
| Responsible Party | Richard Warren, richard.warren@renishaw.com |
| Technical Contact | Dave Bozich, Renishaw Inc, dave.bozich@renishaw.com |
| Test Firm | Sandra Kitson-Wilms, TUV SUD Limited, Sandra.Kitson-Wilms@tuvsud.com |
| TCB Email | carl.hunt@tuvsud.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| x5cKGDzDabm54S2uUC5AQg== | 2026-04-02 | Original Equipment |
| bZsLKLumsAfz70Bc24OMxQ== | 2026-04-02 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application x5cKGDzDabm54S2uUC5AQg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD BABT UNLIMITED Octagon House, Concorde Way Segensworth North Fareham, PO15 5RL United Kingdom |
Date of Grant: 04/02/2026 Application Dated: 04/01/2026 |
| Renishaw plc |
| New Mills, Wotton Under Edge |
| Gloucestershire GL12 8JR, United Kingdom |
| Attention: Richard Warren , Regulatory Compliance Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | KQGRMM-QE |
| Name of Grantee: | Renishaw plc |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | The Renishaw RMM-QE (Radio Machine Module) is designed to work with the Renishaw USI (Universal Sensor Interface) and is designed to support Renishaw probes that require rich data processing. |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00253 |
| Power is peak conducted as tested. Device is RF Exposure exempt under 1.1307(b)(3)(i)(B) 'Option B' (SAR Based Exemption) |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application bZsLKLumsAfz70Bc24OMxQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD BABT UNLIMITED Octagon House, Concorde Way Segensworth North Fareham, PO15 5RL United Kingdom |
Date of Grant: 04/02/2026 Application Dated: 04/01/2026 |
| Renishaw plc |
| New Mills, Wotton Under Edge |
| Gloucestershire GL12 8JR, United Kingdom |
| Attention: Richard Warren , Regulatory Compliance Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | KQGRMM-QE |
| Name of Grantee: | Renishaw plc |
| Equipment Class: | Digital Transmission System |
| Notes: | The Renishaw RMM-QE (Radio Machine Module) is designed to work with the Renishaw USI (Universal Sensor Interface) and is designed to support Renishaw probes that require rich data processing. |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00252 |
| Power is peak conducted as tested. Device is RF Exposure exempt under 1.1307(b)(3)(i)(B) 'Option B' (SAR Based Exemption) |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |