| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1850-1910 MHz | Original Equipment | 2003-11-21 |
| 1850-1910 MHz | Original Equipment | 2003-07-23 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| safety information | Users Manual | 2003-11-21 | PDF 155.1 KB |
| user guide | Users Manual | 2003-11-21 | PDF 1.1 MB |
| user manual instructions Metadata only | Users Manual | PDF 148 KB | |
| int photos | Internal Photos | 2003-11-21 | PDF 2.6 MB |
| Int photos Metadata only | Internal Photos | PDF 2.6 MB | |
| ext photos | External Photos | 2003-11-21 | PDF 141.1 KB |
| id label | ID Label/Location Info | 2003-11-21 | PDF 254 KB |
| ID label Metadata only | ID Label/Location Info | PDF 254 KB | |
| request letter Metadata only | Block Diagram | PDF 67.9 KB | |
| setup photos | Test Setup Photos | 2003-11-21 | PDF 6.8 KB |
| test setup Metadata only | Test Setup Photos | PDF 5 KB | |
| Test report1 | Test Report | 2003-11-21 | PDF 428.3 KB |
| Test report2 | Test Report | 2003-11-21 | PDF 1.1 MB |
| EMC report1 Metadata only | Test Report | PDF 2.4 MB | |
| EMC report2 Metadata only | Test Report | PDF 3 MB | |
| attestation letter | Attestation Statements | 2003-11-21 | PDF 29 KB |
| attestation letter Metadata only | Attestation Statements | PDF 29 KB | |
| confidentiality letter | Cover Letter(s) | 2003-11-21 | PDF 16.7 KB |
| cover letter | Cover Letter(s) | 2003-11-21 | PDF 14.6 KB |
| deferral date | Cover Letter(s) | 2003-11-21 | PDF 59.6 KB |
| response to fcc questions | Cover Letter(s) | 2003-11-21 | PDF 71.6 KB |
| confidentiality letter Metadata only | Cover Letter(s) | PDF 15.4 KB | |
| cover letter | Cover Letter(s) | PDF 12.9 KB | |
| mod confidential letter | Cover Letter(s) | PDF 66.9 KB | |
| SAR report | RF Exposure Info | 2003-11-21 | PDF 3.9 MB |
| SAR calibration files Metadata only | RF Exposure Info | PDF 1,005 KB | |
| SAR report Metadata only | RF Exposure Info | PDF 2.1 MB | |
| block diagram Metadata only | Block Diagram | PDF 312.2 KB | |
| block diagram Metadata only | Block Diagram | PDF 29.3 KB | |
| schematics Metadata only | Schematics | PDF 2 MB | |
| schematics Metadata only | Schematics | PDF 1.6 MB | |
| oper description Metadata only | Operational Description | PDF 10.5 KB | |
| oper description Metadata only | Operational Description | PDF 8.7 KB | |
| parts list and tune up info Metadata only | Parts List/Tune Up Info | PDF 201.9 KB | |
| parts list and tune up info Metadata only | Parts List/Tune Up Info | PDF 143.3 KB |
Application Information
| Application ID | q6Bw7JC+88Xm8I4C+oYlzA== |
|---|---|
| Final Action Date | 2003-11-21 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0006040703 |
| Model | R6030GE |
| Frequency Range | 1850-1910 MHz |
| Equipment Class | PCE - PCS Licensed Transmitter held to ear |
| Device Description | BlackBerry Wireless Handheld |
| Responsible Party | Jason W Jantzi, Team Lead, RF Design, jjantzi@blackberry.com |
| Technical Contact | Masud S Attayi, Research In Motion Limited, mattayi@rim.net |
| Non-Technical Contact | Masud S Attayi, Research In Motion Limited, (519) 888-7465 |
| Test Firm | Masud Attayi, BlackBerry RTS, mattayi@blackberry.com |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power is EIRP. This device contains 900 MHz GSM and 1800 MHz DCS functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. SAR compliance for body-worn operating configurations is limited to the specific belt-clips, holsters, or accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Highest reported SAR values are: head 1.48 W/kg, body 1.26 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| q6Bw7JC+88Xm8I4C+oYlzA== | 2003-11-21 | Original Equipment |
| 4rTzFKWYUyCI+gU0gdNWuQ== | 2003-07-23 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application q6Bw7JC+88Xm8I4C+oYlzA==
This application does not exist.
EAS Grant - Application q6Bw7JC+88Xm8I4C+oYlzA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
BlackBerry Limited 2200 University Avenue East Waterloo, Ontario, N2K 0A7 Canada |
Date of Grant: 11/21/2003 Application Dated: 07/23/2003 |
| Attention: Jason Jantzi , Team Lead, RF Design |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | L6AR6030GE |
| Name of Grantee: | BlackBerry Limited |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | BlackBerry Wireless Handheld |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.0 - 1910.0 | 0.91 | 0.1 PM | 248KGXW |
| Output power is EIRP. This device contains 900 MHz GSM and 1800 MHz DCS functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. SAR compliance for body-worn operating configurations is limited to the specific belt-clips, holsters, or accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Highest reported SAR values are: head 1.48 W/kg, body 1.26 W/kg. |
| Mail To: |