FCC ID LEAABN25ARA00

2-Way Pager

by Unication Co Ltd

Grantee Code: LEA   Product Code: ABN25ARA00
Latest application date: 2006-02-24

FCC ID Device Details

FCC IDLEAABN25ARA00
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeLEA
Product CodeABN25ARA00
Applicant BusinessUnication Co Ltd 🇹🇼
Related Domains uniamericas.com
Equipment Class2-Way Pager
Test FirmTimco Engineering, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
901-902 MHzOriginal Equipment2006-02-24

Exhibits

DocumentTypeAvailableFile
quickstart users manualUsers Manual2006-02-24PDF 425.3 KB
users manualUsers Manual2006-02-24PDF 610.8 KB
internal photosInternal Photos2006-02-24PDF 827.8 KB
external photosExternal Photos2006-02-24PDF 616.9 KB
label locationID Label/Location Info2006-02-24PDF 135.9 KB
label sampleID Label/Location Info2006-02-24PDF 23.3 KB
test setup photosTest Setup Photos2006-02-24PDF 304.2 KB
test report 1Test Report2006-02-24PDF 67.5 KB
test report 2Test Report2006-02-24PDF 131.5 KB
request for confidentialityCover Letter(s)2006-02-24PDF 14.5 KB
sar probe calibrationRF Exposure Info2006-02-24PDF 1.4 MB
sar reportRF Exposure Info2006-02-24PDF 1.3 MB
sar system validationRF Exposure Info2006-02-24PDF 1.1 MB
tune up infoParts List/Tune Up Info2006-02-24PDF 14.2 KB
block diagram Metadata onlyBlock DiagramPDF 115.4 KB
schematics 1 Metadata onlySchematicsPDF 55.8 KB
schematics 2 Metadata onlySchematicsPDF 1.1 MB
operational description Metadata onlyOperational DescriptionPDF 346.8 KB
parts list Metadata onlyParts List/Tune Up InfoPDF 26.1 KB

Application Information

Application ID87YLPlJ+GZp4xcRrugtgpg==
Final Action Date2006-02-24
Application PurposeOriginal Equipment
Applicant FRN0014497606
ModelABN25ARA00
Frequency Range901-902 MHz
Equipment ClassPCT - PCS Licensed Transmitter worn on body
Device Description2-Way Pager
Responsible PartyRobert Marchetto, General Manager, rmarchetto@uniamericas.com , 886-2-22999678
Test FirmSid Sanders, Timco Engineering, Inc., info@timcoengr.com , 352-472-5500
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is ERP. SAR compliance for body-worn operating configurations is limited to the specific configuration tested in this filing and is based on a separation distance of 1.2 cm between the back of the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metallic components. This device must not exceed a maximum transmitting duty factor of 22%, as documented in this filing The highest reported SAR value is: Body: 1.01 W/kg.

Applications

Application IDDatePurpose
87YLPlJ+GZp4xcRrugtgpg==2006-02-24Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
901-902 MHz0.29000001.0000000000ppm10K0F1D24D

Grants

TCB Grant - Application 87YLPlJ+GZp4xcRrugtgpg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 02/24/2006

Application Dated: 02/24/2006
Unication Co Ltd
5F, No. 6, Wu-Kung 5 Rd.
Hsinchuang City, Taipei,
Taiwan
 
Attention: Robert Marchetto , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LEAABN25ARA00
Name of Grantee:  Unication Co Ltd
Equipment Class: PCS Licensed Transmitter worn on body
Notes: 2-Way Pager
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 0.29 1.0  PM 10K0F1D

Power output listed is ERP. SAR compliance for body-worn operating configurations is limited to the specific configuration tested in this filing and is based on a separation distance of 1.2 cm between the back of the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metallic components. This device must not exceed a maximum transmitting duty factor of 22%, as documented in this filing The highest reported SAR value is: Body: 1.01 W/kg.

EAS Grant - Application 87YLPlJ+GZp4xcRrugtgpg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Unication Co Ltd
5F, No. 6, Wu-Kung 5 Rd.
Hsinchuang City, Taipei,
Taiwan
  Date of Grant: 02/24/2006

Application Dated: 02/24/2006
 
Attention: Robert Marchetto , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LEAABN25ARA00
Name of Grantee:  Unication Co Ltd
Equipment Class: PCS Licensed Transmitter worn on body
Notes: 2-Way Pager
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 0.29 1.0  PM 10K0F1D

Power output listed is ERP. SAR compliance for body-worn operating configurations is limited to the specific configuration tested in this filing and is based on a separation distance of 1.2 cm between the back of the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metallic components. This device must not exceed a maximum transmitting duty factor of 22%, as documented in this filing The highest reported SAR value is: Body: 1.01 W/kg.



Mail To: