FCC ID LLBY84000
Synergize RF network utility I210+ meter transponder
by Aclara Technologies LLC
Grantee Code: LLB Product Code: Y84000
Latest application date: 2015-09-29
Device Images

























FCC ID Device Details
| FCC ID | LLBY84000 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | LLB |
| Product Code | Y84000 |
| Applicant Business | Aclara Technologies LLC 🇺🇸 |
| Related Domains | |
| Equipment Class | Synergize RF network utility I210+ meter transponder |
| Test Firm | Radiometrics Midwest Corp. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 450-470 MHz | Original Equipment | 2015-09-29 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2015-09-29 | PDF 3.5 MB |
| Int Photos | Internal Photos | 2015-09-29 | PDF 540.1 KB |
| Ext Photos | External Photos | 2015-09-29 | PDF 138.9 KB |
| FCC ID Label | ID Label/Location Info | 2015-09-29 | PDF 23.4 KB |
| Setup Photos | Test Setup Photos | 2015-09-29 | PDF 492.4 KB |
| Test Report | Test Report | 2015-09-29 | PDF 336.2 KB |
| Agency Letter | Cover Letter(s) | 2015-09-29 | PDF 91.1 KB |
| Confidentiality Letter | Cover Letter(s) | 2015-09-29 | PDF 27.4 KB |
| POA | Cover Letter(s) | 2015-09-29 | PDF 82.5 KB |
| RF Exposure | RF Exposure Info | 2015-09-29 | PDF 11.1 KB |
| Tune up Procedure | Parts List/Tune Up Info | 2015-09-29 | PDF 6.7 KB |
| Block Diagram Metadata only | Block Diagram | PDF 15.9 KB | |
| Schematics Metadata only | Schematics | PDF 75.1 KB | |
| Operation Description Metadata only | Operational Description | PDF 55.2 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 62.8 KB |
Application Information
| Application ID | 8pdVrMtYHCsY+HEjJVR4Lg== |
|---|---|
| Final Action Date | 2015-09-29 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0004168324 |
| Model | Y84000 |
| Frequency Range | 450-470 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | Synergize RF network utility I210+ meter transponder |
| Responsible Party | John Cunningham, VP, Chief Engineer, jcunningham@aclara.com |
| Test Firm | Joseph Strzelecki, Radiometrics Midwest Corp., joe@radiomet.com |
| TCB Email | bacl.regulatory@baclcorp.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of § 1.1307(b)(3), for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 8pdVrMtYHCsY+HEjJVR4Lg== | 2015-09-29 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application 8pdVrMtYHCsY+HEjJVR4Lg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 09/29/2015 Application Dated: 09/29/2015 |
| Aclara Technologies LLC |
| 77 Westport Plaza Drive |
| Suite 500 |
| St. Louis, MO 63146 |
| Attention: John Cunningham , VP, Chief Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | LLBY84000 |
| Name of Grantee: | Aclara Technologies LLC |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Synergize RF network utility I210+ meter transponder |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.0 - 470.0 | 0.457 | 2.5 PM | 11K2F1D |
| Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of § 1.1307(b)(3), for satisfying RF exposure compliance. |
EAS Grant - Application 8pdVrMtYHCsY+HEjJVR4Lg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Aclara Technologies LLC 77 Westport Plaza Drive Suite 500 St. Louis, MO 63146 United States |
Date of Grant: 09/29/2015 Application Dated: 09/29/2015 |
| Attention: John Cunningham , VP, Chief Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | LLBY84000 |
| Name of Grantee: | Aclara Technologies LLC |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Synergize RF network utility I210+ meter transponder |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.0 - 470.0 | 0.457 | 2.5 PM | 11K2F1D |
| Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of § 1.1307(b)(3), for satisfying RF exposure compliance. |
| Mail To: |