FCC ID LNQWCB5000

11ac Wireless Ethernet Bridge

by Actiontec Electronics Inc

Grantee Code: LNQ   Product Code: WCB5000
Latest application date: 2015-09-23

FCC ID Device Details

FCC IDLNQWCB5000
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeLNQ
Product CodeWCB5000
Applicant BusinessActiontec Electronics Inc 🇺🇸
Related Domains actiontec.com
Equipment Class11ac Wireless Ethernet Bridge
Test FirmMicom Labs

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2015-09-23
2412-2462 MHzOriginal Equipment2015-09-23

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2016-03-20PDF 623.6 KB
IntInternal Photos2016-03-20PDF 908.3 KB
ExtExternal Photos2016-03-20PDF 926.9 KB
LabelID Label/Location Info2015-09-23PDF 85 KB
SetupTest Setup Photos2016-03-20PDF 1.1 MB
DTSTest Report2015-09-23PDF 4.2 MB
NIITest Report2015-09-23PDF 3.9 MB
AuthorizationCover Letter(s)2015-09-23PDF 32.1 KB
ConfidCover Letter(s)2015-09-23PDF 37.6 KB
Configuration ControlCover Letter(s)2015-09-23PDF 33.4 KB
DeclarationCover Letter(s)2015-09-23PDF 32.9 KB
Declaration of SimilarityCover Letter(s)2015-09-23PDF 30.5 KB
Declation of SimilarityCover Letter(s)2015-09-23PDF 30.5 KB
DofCCover Letter(s)2015-09-23PDF 30.7 KB
Software Configuration ControlCover Letter(s)2015-09-23PDF 32.9 KB
RFxRF Exposure Info2015-09-23PDF 72.7 KB
Block Metadata onlyBlock DiagramPDF 157.4 KB
Schema Metadata onlySchematicsPDF 1.2 MB
Schema Metadata onlySchematicsPDF 66.2 KB
Ops Metadata onlyOperational DescriptionPDF 66.2 KB
Ops Metadata onlyOperational DescriptionPDF 1.2 MB
BOM Metadata onlyParts List/Tune Up InfoPDF 111.3 KB

Application Information

Application IDsqOVL7hGRo34h5Cc447aHg==
Final Action Date2015-09-23
Application PurposeOriginal Equipment
Applicant FRN0005810783
ModelWCB5000
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device Description11ac Wireless Ethernet Bridge
Responsible PartyBrian Henrichs, President, bhenrichs@actiontec.com , 4088579658
Technical ContactGordon Hurst, MiCOM Labs, certification@micomlabs.com , (925)462-0304
Test FirmGordon Hurst, Micom Labs, gordon_hurst@micomlabs.com , 925-462-0304
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date03/20/2016
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is maximum combined Conducted power operating in a 2X2 MIMO configuration. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter within a device, except in accordance with accepted multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
sqOVL7hGRo34h5Cc447aHg==2015-09-23Original Equipment
Gu5C6qLg6toJD++WB8WRkA==2015-09-23Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.424000015CCC, MO
5180-5240 MHz0.35815ECC, MO
5745-5825 MHz0.45215ECC, MO

Grants

TCB Grant - Application sqOVL7hGRo34h5Cc447aHg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 09/23/2015

Application Dated: 09/22/2015
Actiontec Electronics Inc
2445 Augustine Drive
Suite 501
Santa Clara, CA 95054
 
Attention: Brian Henrichs , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LNQWCB5000
Name of Grantee:  Actiontec Electronics Inc
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 11ac Wireless Ethernet Bridge
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.358  
CC MO 15E 5745.0  -  5825.0 0.452  

Power Output listed is maximum combined Conducted power operating in a 2X2 MIMO configuration. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter within a device, except in accordance with accepted multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application sqOVL7hGRo34h5Cc447aHg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Actiontec Electronics Inc
2445 Augustine Drive Suite 501
Santa Clara, CA 95054
United States
  Date of Grant: 09/23/2015

Application Dated: 09/22/2015
 
Attention: Brian Henrichs , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LNQWCB5000
Name of Grantee:  Actiontec Electronics Inc
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 11ac Wireless Ethernet Bridge
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.358  
CC MO 15E 5745.0  -  5825.0 0.452  

Power Output listed is maximum combined Conducted power operating in a 2X2 MIMO configuration. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter within a device, except in accordance with accepted multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application Gu5C6qLg6toJD++WB8WRkA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 09/23/2015

Application Dated: 09/22/2015
Actiontec Electronics Inc
2445 Augustine Drive
Suite 501
Santa Clara, CA 95054
 
Attention: Brian Henrichs , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LNQWCB5000
Name of Grantee:  Actiontec Electronics Inc
Equipment Class: Digital Transmission System
Notes: 11ac Wireless Ethernet Bridge
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.424  

Power Output listed is maximum combined Conducted power operating in a 2X2 MIMO configuration. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter within a device, except in accordance with accepted multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application Gu5C6qLg6toJD++WB8WRkA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Actiontec Electronics Inc
2445 Augustine Drive Suite 501
Santa Clara, CA 95054
United States
  Date of Grant: 09/23/2015

Application Dated: 09/22/2015
 
Attention: Brian Henrichs , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LNQWCB5000
Name of Grantee:  Actiontec Electronics Inc
Equipment Class: Digital Transmission System
Notes: 11ac Wireless Ethernet Bridge
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.424  

Power Output listed is maximum combined Conducted power operating in a 2X2 MIMO configuration. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter within a device, except in accordance with accepted multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: