FCC ID LRUSVR-300UD

Vehicular Repeater System (VRS)

by Pyramid Communications

Grantee Code: LRU   Product Code: SVR300UD
Latest application date: 2018-07-03

FCC ID Device Details

FCC IDLRUSVR-300UD
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeLRU
Product CodeSVR300UD
Applicant BusinessPyramid Communications 🇺🇸
Related Domains pyramidcomm.com
Equipment ClassVehicular Repeater System (VRS)
Test FirmBay Area Compliance Laboratories Corporation

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-512 MHzClass II permissive change or modification of presently authorized equipment2018-07-03
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: K44471200 Grant Date: 10/05/20142018-06-08
450-512 MHzChange in identification of presently authorized equipment. Original FCC ID: K44471200 Grant Date: 01/31/20182018-06-08

Exhibits

DocumentTypeAvailableFile
Internal PhotosInternal Photos2018-07-03PDF 534.4 KB
External PhotosExternal Photos2018-07-03PDF 420.3 KB
Label and Label LocationID Label/Location Info2018-07-03PDF 212.6 KB
Label & Label LocationID Label/Location Info2018-06-08PDF 119.3 KB
Label and Label LocationID Label/Location Info2018-06-08PDF 109.9 KB
Test ReportTest Report2018-07-03PDF 361.7 KB
Permissive Change Declaration LetterCover Letter(s)2018-07-03PDF 44.7 KB
Authorization Letter from Original GranteeCover Letter(s)2018-06-08PDF 41 KB
Declaration of SimilarityCover Letter(s)2018-06-08PDF 110.8 KB
Request Change of Identification UHF-DCover Letter(s)2018-06-08PDF 92.9 KB

Application Information

Application IDsmU/4b9gEZ6ou7ZskMenyQ==
Final Action Date2018-07-03
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0010330405
ModelSVR-300UD
Frequency Range450-512 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionVehicular Repeater System (VRS)
Responsible PartyChristopher Carbajal, Vice President of Engineering, chris@pyramidcomm.com , 714 901-5462
Test FirmLisa Tang, Bay Area Compliance Laboratories Corporation, lisat@baclcorp.com , 408-732-9162
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsClass II Permissive Change to use the original radio hardware in a new enclosure and limiting the max power to 2 W described in this filing. Output power is listed as conducted and is switchable between 5 and 45 watts. Compliance with RF exposure conditions is based on a duty factor not exceeding 50%. End-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 40 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

Applications

Application IDDatePurpose
smU/4b9gEZ6ou7ZskMenyQ==2018-07-03Class II permissive change or modification of presently authorized equipment
qlDBb8SMQzzBH97WFMwu0g==2018-06-08Change in identification of presently authorized equipment. Original FCC ID: K44471200 Grant Date: 10/05/2014
LPRdnlpC1IvJv7A2PimoCQ==2018-06-08Change in identification of presently authorized equipment. Original FCC ID: K44471200 Grant Date: 01/31/2018

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
450-512 MHz451ppm4K00F1D22, 74, 9BD, EF, ES
450-512 MHz451ppm4K00F7W22, 74, 9BD, EF, ES
450-512 MHz451ppm4K00F2D22, 74, 9BD, EF, ES
450-512 MHz451ppm7K60FXD22, 74, 9BD, EF, ES
450-512 MHz451ppm7K60FXE22, 74, 9BD, EF, ES
450-512 MHz451ppm11K0F3E22, 74, 9BD, EF
450-512 MHz451ppm8K10F1E22, 74, 9BD, EF, ES
450-512 MHz451ppm8K10F1D22, 74, 9BD, EF, ES
450-512 MHz451ppm8K10F1W22, 74, 9BD, EF, ES
450-512 MHz451ppm8K30F1E22, 74, 9BD, EF, ES
450-512 MHz451ppm8K30F1D22, 74, 9BD, EF, ES
450-512 MHz451ppm8K30F7W22, 74, 9BD, EF, ES
450-512 MHz451ppm4K00F1E22, 74, 9BD, EF, ES
2402-2480 MHz0.001200015C

Grants

TCB Grant - Application smU/4b9gEZ6ou7ZskMenyQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 07/03/2018

Application Dated: 07/03/2018
Pyramid Communications
37 Shield
Irvine, CA 92618
 
Attention: Christopher Carbajal , Vice President of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LRUSVR-300UD
Name of Grantee:  Pyramid Communications
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Vehicular Repeater System (VRS)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BD 22, 74, 90 470.0  -  512.0 45.0 1.0  PM 16K0F3E
BD EF 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 11K0F3E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K10F1E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K10F1D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K10F1W
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K30F1E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K30F1D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K30F7W
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F1E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F1D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F7W
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F2D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 7K60FXD
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 7K60FXE

Class II Permissive Change to use the original radio hardware in a new enclosure and limiting the max power to 2 W described in this filing.

Output power is listed as conducted and is switchable between 5 and 45 watts. Compliance with RF exposure conditions is based on a duty factor not exceeding 50%. End-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 40 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.


BD: The output power is continuously variable from the value listed in this entry to 10%-15% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.
ES: This equipment is capable of supporting a minimum data rate of 4800 bits per second per 6.25 kHz of channel bandwidth.

EAS Grant - Application smU/4b9gEZ6ou7ZskMenyQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Pyramid Communications
37 Shield
Irvine, CA 92618
United States
  Date of Grant: 07/03/2018

Application Dated: 07/03/2018
 
Attention: Christopher Carbajal , Vice President of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LRUSVR-300UD
Name of Grantee:  Pyramid Communications
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Vehicular Repeater System (VRS)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BD 22, 74, 90 470.0  -  512.0 45.0 1.0  PM 16K0F3E
BD EF 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 11K0F3E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K10F1E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K10F1D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K10F1W
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K30F1E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K30F1D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K30F7W
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F1E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F1D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F7W
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F2D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 7K60FXD
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 7K60FXE

Class II Permissive Change to use the original radio hardware in a new enclosure and limiting the max power to 2 W described in this filing.

Output power is listed as conducted and is switchable between 5 and 45 watts. Compliance with RF exposure conditions is based on a duty factor not exceeding 50%. End-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 40 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.


BD: The output power is continuously variable from the value listed in this entry to 10%-15% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.
ES: This equipment is capable of supporting a minimum data rate of 4800 bits per second per 6.25 kHz of channel bandwidth.

TCB Grant - Application qlDBb8SMQzzBH97WFMwu0g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 06/08/2018

Application Dated: 06/08/2018
Pyramid Communications
37 Shield
Irvine, CA 92618
 
Attention: Christopher Carbajal , Vice President of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LRUSVR-300UD
Name of Grantee:  Pyramid Communications
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Vehicular Repeater System (VRS)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0012  

Output power listed is conducted.

EAS Grant - Application qlDBb8SMQzzBH97WFMwu0g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Pyramid Communications
37 Shield
Irvine, CA 92618
United States
  Date of Grant: 06/08/2018

Application Dated: 06/08/2018
 
Attention: Christopher Carbajal , Vice President of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LRUSVR-300UD
Name of Grantee:  Pyramid Communications
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Vehicular Repeater System (VRS)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0012  

Output power listed is conducted.



TCB Grant - Application LPRdnlpC1IvJv7A2PimoCQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 06/08/2018

Application Dated: 06/08/2018
Pyramid Communications
37 Shield
Irvine, CA 92618
 
Attention: Christopher Carbajal , Vice President of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LRUSVR-300UD
Name of Grantee:  Pyramid Communications
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Vehicular Repeater System (VRS)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BD 22, 74, 90 470.0  -  512.0 45.0 1.0  PM 16K0F3E
BD EF 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 11K0F3E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K10F1E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K10F1D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K10F1W
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K30F1E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K30F1D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K30F7W
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F1E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F1D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F7W
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F2D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 7K60FXD
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 7K60FXE

Output power is listed as conducted and is switchable between 5 and 45 watts. Compliance with RF exposure conditions is based on a duty factor not exceeding 50%. End-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 40 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

BD: The output power is continuously variable from the value listed in this entry to 10%-15% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.
ES: This equipment is capable of supporting a minimum data rate of 4800 bits per second per 6.25 kHz of channel bandwidth.

EAS Grant - Application LPRdnlpC1IvJv7A2PimoCQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Pyramid Communications
37 Shield
Irvine, CA 92618
United States
  Date of Grant: 06/08/2018

Application Dated: 06/08/2018
 
Attention: Christopher Carbajal , Vice President of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LRUSVR-300UD
Name of Grantee:  Pyramid Communications
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Vehicular Repeater System (VRS)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BD 22, 74, 90 470.0  -  512.0 45.0 1.0  PM 16K0F3E
BD EF 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 11K0F3E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K10F1E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K10F1D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K10F1W
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K30F1E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K30F1D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 8K30F7W
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F1E
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F1D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F7W
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 4K00F2D
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 7K60FXD
BD EF ES 22, 74, 90 450.0  -  512.0 45.0 1.0  PM 7K60FXE

Output power is listed as conducted and is switchable between 5 and 45 watts. Compliance with RF exposure conditions is based on a duty factor not exceeding 50%. End-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 40 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.


BD: The output power is continuously variable from the value listed in this entry to 10%-15% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.
ES: This equipment is capable of supporting a minimum data rate of 4800 bits per second per 6.25 kHz of channel bandwidth.

Mail To: