FCC ID LUB-P322SDIO
802.11a/b/g SDIO Card
by Socket Mobile, Inc.
Grantee Code: LUB Product Code: P322SDIO
Latest application date: 2011-08-23
FCC ID Device Details
| FCC ID | LUB-P322SDIO |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | LUB |
| Product Code | P322SDIO |
| Applicant Business | Socket Mobile, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | 802.11a/b/g SDIO Card |
| Test Firm | Intertek Testing Services Taiwan Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2011-08-23 |
| 5260-5320 MHz | Original Equipment | 2011-08-23 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2011-08-23 | PDF 360.4 KB |
| Users Manual | Users Manual | 2011-08-23 | PDF 360.4 KB |
| Internal Photos | Internal Photos | 2011-08-23 | PDF 168.6 KB |
| External Photos | External Photos | 2011-08-23 | PDF 129.6 KB |
| FCC ID Label | ID Label/Location Info | 2011-08-23 | PDF 99.5 KB |
| Test Setup Photos | Test Setup Photos | 2011-08-23 | PDF 192.6 KB |
| DFS Test Report | Test Report | 2011-08-23 | PDF 1.8 MB |
| SAR Test Report | RF Exposure Info | 2011-08-23 | PDF 5.7 MB |
| SAR Test Report | RF Exposure Info | 2011-08-23 | PDF 5.7 MB |
| Test Report | Test Report | 2011-08-23 | PDF 3.5 MB |
| Test Report | Test Report | 2011-08-23 | PDF 3.3 MB |
| DoC Attestation Letter | Attestation Statements | 2011-08-23 | PDF 278.4 KB |
| DoC Statement | Attestation Statements | 2011-08-23 | PDF 278.4 KB |
| Confidential Request Letter | Cover Letter(s) | 2011-08-23 | PDF 565.8 KB |
Application Information
| Application ID | lpWGF78ns9A8iOInXHxQqA== |
|---|---|
| Final Action Date | 2011-08-23 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0004929972 |
| Model | -P322SDIO |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | 802.11a/b/g SDIO Card |
| Responsible Party | Timothy Miller, VP Engineering & Operations, tim@socketmobile.com |
| Test Firm | Yin-Lan Chen, Intertek Testing Services Taiwan Ltd., yinlan.chen@intertek.com |
| TCB Email | bacl.regulatory@baclcorp.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body-worn operating conditions and is limited to the specific configuration tested for this filing. End-users must be informed of the body worn requirements to satisfy RF exposure compliance. This equipment should be installed and operated with minimum distance 0.5 cm between radiator and human body. The highest reported SAR for this device is 2.4 GHz: 0.13 W/Kg (body tissue); 5 GHz: 0.72 W/Kg (body tissue). |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| lpWGF78ns9A8iOInXHxQqA== | 2011-08-23 | Original Equipment |
| LWjgP52VAOncaaIC/RTVeQ== | 2011-08-23 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application LWjgP52VAOncaaIC/RTVeQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 08/23/2011 Application Dated: 08/23/2011 |
| Socket Mobile, Inc. |
| 39700 Eureka Drive |
| Newark, CA 94560-4808 |
| Attention: Timothy Miller , VP Engineering & Operations |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | LUB-P322SDIO |
| Name of Grantee: | Socket Mobile, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 802.11a/b/g SDIO Card |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC ND | 15E | 5260.0 - 5320.0 | 0.167 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.15 | ||
| CC ND | 15E | 5745.0 - 5805.0 | 0.133 |
| Power output listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body-worn operating conditions and is limited to the specific configuration tested for this filing. End-users must be informed of the body worn requirements to satisfy RF exposure compliance. This equipment should be installed and operated with minimum distance 0.5 cm between radiator and human body. The highest reported body SAR for this device: 0.13 W/Kg in 2.4 GHz, 0.72 W/Kg in 5 GHz. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application LWjgP52VAOncaaIC/RTVeQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Socket Mobile, Inc. 39700 Eureka Drive Newark, CA 94560-4808 United States |
Date of Grant: 08/23/2011 Application Dated: 08/23/2011 |
| Attention: Timothy Miller , VP Engineering & Operations |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | LUB-P322SDIO |
| Name of Grantee: | Socket Mobile, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 802.11a/b/g SDIO Card |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC ND | 15E | 5260.0 - 5320.0 | 0.167 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.15 | ||
| CC ND | 15E | 5745.0 - 5805.0 | 0.133 |
| Power output listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body-worn operating conditions and is limited to the specific configuration tested for this filing. End-users must be informed of the body worn requirements to satisfy RF exposure compliance. This equipment should be installed and operated with minimum distance 0.5 cm between radiator and human body. The highest reported body SAR for this device: 0.13 W/Kg in 2.4 GHz, 0.72 W/Kg in 5 GHz. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 08/23/2011 Application Dated: 08/23/2011 |
| Socket Mobile, Inc. |
| 39700 Eureka Drive |
| Newark, CA 94560-4808 |
| Attention: Timothy Miller , VP Engineering & Operations |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | LUB-P322SDIO |
| Name of Grantee: | Socket Mobile, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | 802.11a/b/g SDIO Card |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.0647 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.1178 |
| Power output listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body-worn operating conditions and is limited to the specific configuration tested for this filing. End-users must be informed of the body worn requirements to satisfy RF exposure compliance. This equipment should be installed and operated with minimum distance 0.5 cm between radiator and human body. The highest reported SAR for this device is 2.4 GHz: 0.13 W/Kg (body tissue); 5 GHz: 0.72 W/Kg (body tissue). |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application lpWGF78ns9A8iOInXHxQqA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Socket Mobile, Inc. 39700 Eureka Drive Newark, CA 94560-4808 United States |
Date of Grant: 08/23/2011 Application Dated: 08/23/2011 |
| Attention: Timothy Miller , VP Engineering & Operations |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | LUB-P322SDIO |
| Name of Grantee: | Socket Mobile, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | 802.11a/b/g SDIO Card |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.0647 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.1178 |
| Power output listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body-worn operating conditions and is limited to the specific configuration tested for this filing. End-users must be informed of the body worn requirements to satisfy RF exposure compliance. This equipment should be installed and operated with minimum distance 0.5 cm between radiator and human body. The highest reported SAR for this device is 2.4 GHz: 0.13 W/Kg (body tissue); 5 GHz: 0.72 W/Kg (body tissue). |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |