FCC ID LYHW700-2-V1

2.4/5 GHz IEEE 802.11a/b/g WLAN Access Point

by Siemens AG

Grantee Code: LYH   Product Code: W7002V1
Latest application date: 2006-09-28

FCC ID Device Details

FCC IDLYHW700-2-V1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeLYH
Product CodeW7002V1
Applicant BusinessSiemens AG 🇩🇪
Related Domains siemens.com
Equipment Class2.4/5 GHz IEEE 802.11a/b/g WLAN Access Point
Test FirmCTC advanced GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2006-09-28
2412-2462 MHzClass II permissive change or modification of presently authorized equipment2005-03-18
5250-5350 MHzOriginal Equipment2004-06-23
2412-2462 MHzOriginal Equipment2004-06-23

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2004-06-23PDF 2.8 MB
Internal PhotosInternal Photos2004-06-23PDF 1.3 MB
Internal PhotosInternal Photos2004-06-23PDF 1.3 MB
External PhotosExternal Photos2005-03-18PDF 546.1 KB
External PhotosExternal Photos2004-06-23PDF 507.6 KB
External PhotosExternal Photos2004-06-23PDF 507.6 KB
LabelID Label/Location Info2004-06-23PDF 197.7 KB
Test Setup PhotosTest Setup Photos2006-09-28PDF 862 KB
Test Setup PhotosTest Setup Photos2005-03-18PDF 284.8 KB
Test Setup PhotosTest Setup Photos2004-06-23PDF 480.3 KB
Test Setup PhotosTest Setup Photos2004-06-23PDF 383.4 KB
Test Report Part 1Test Report2006-09-28PDF 3.7 MB
Test Report Part 2Test Report2006-09-28PDF 2.7 MB
Test ReportTest Report2005-03-18PDF 1.1 MB
Test ReportTest Report2004-06-23PDF 2.9 MB
Test ReportTest Report2004-06-23PDF 3.6 MB
Cover LetterCover Letter(s)2006-09-28PDF 19.2 KB
PCII Request LetterCover Letter(s)2005-03-18PDF 30.4 KB
Confidentiality RequestCover Letter(s)2004-06-23PDF 27.5 KB
Cover LetterCover Letter(s)2004-06-23PDF 49 KB
RF Exposure InfoRF Exposure Info2004-06-23PDF 29.7 KB
RF Exposure InfoRF Exposure Info2004-06-23PDF 58.3 KB
Block Diagram AP Metadata onlyBlock DiagramPDF 142.3 KB
Block Diagram RF Metadata onlyBlock DiagramPDF 1 MB
Circuit Diagram AP Metadata onlySchematicsPDF 319.6 KB
Circuit Diagram RF Metadata onlySchematicsPDF 857.3 KB
PCB AP Metadata onlySchematicsPDF 267.5 KB
PCB RF Metadata onlySchematicsPDF 1.3 MB
Operational Description AP Metadata onlyOperational DescriptionPDF 350.5 KB
Operational Description RF Metadata onlyOperational DescriptionPDF 64.7 KB

Application Information

Application IDegpDRJiWCqe+tiKjrL7bmA==
Final Action Date2006-09-28
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0014620876
ModelW700-2-V1
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device Description2.4/5 GHz IEEE 802.11a/b/g WLAN Access Point
Responsible PartyChristian Funk, christian.funk@siemens.com , +4972166720616
Test FirmGerald Schmidt, CTC advanced GmbH, mail@ctcadvanced.com , 49-681-598-0
TCB Emailgerald.schmidt@ict.cetecom.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPCII to allow 5.15 – 5.25 GHz operation. This device must be professionally installed. Power Output listed is conducted. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Operations in the 5.25-5.35GHz band are subject to Section 15.37(l) transition period.

Applications

Application IDDatePurpose
egpDRJiWCqe+tiKjrL7bmA==2006-09-28Class II permissive change or modification of presently authorized equipment
iTnLGR3hxuQfwRIMR8Uj/Q==2005-03-18Class II permissive change or modification of presently authorized equipment
ZkVeyYnxOpx7tjaozlLOPQ==2004-06-23Original Equipment
BDzFFB2QYpundbDq7Qs6/g==2004-06-23Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.580000015C36, CC, CE
2412-2462 MHz0.580000015C36, CC
5180-5240 MHz0.01615E36, CC
5250-5350 MHz0.2715E36, CC, CE
5260-5320 MHz0.04515E36, CC
5725-5825 MHz0.2515E36, CC, CE
5745-5805 MHz0.0315E36, CC

Grants

TCB Grant - Application ZkVeyYnxOpx7tjaozlLOPQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CTC advanced GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 06/23/2004

Application Dated: 06/23/2004
Siemens AG
Type Test Center Karlsruhe
Oestliche Rheinbrueckenstr. 50
D-76181 Karlsruhe,
Germany
 
Attention: Christian Funk

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LYHW700-2-V1
Name of Grantee:  Siemens AG
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 2.4/5 GHz IEEE 802.11a/b/g WLAN Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
36 CC CE 15E 5250.0  -  5350.0 0.27  
36 CC CE 15E 5725.0  -  5825.0 0.25  

This device must be professionally installed.Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

36: Certain antennas used with this equipment require a minimum cable length, or have output power limitations as documented in the application.
CC: This device is certified pursuant to two different Part 15 rules sections.
CE: This device has shown compliance with the conducted emissions limits in 15.107, 15.207, or 18.307 adopted under FCC 02-157 (ET Docket 98-80). The device may be marketed after July 11, 2005, and is not affected by the 15.37(j) or 18.123 transition provisions.

EAS Grant - Application ZkVeyYnxOpx7tjaozlLOPQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Siemens AG
Type Test Center Karlsruhe Oestliche Rheinbrueckenstr. 50
D-76181 Karlsruhe,
Germany
  Date of Grant: 06/23/2004

Application Dated: 06/23/2004
 
Attention: Christian Funk

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LYHW700-2-V1
Name of Grantee:  Siemens AG
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 2.4/5 GHz IEEE 802.11a/b/g WLAN Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
36 CC CE 15E 5250.0  -  5350.0 0.27  
36 CC CE 15E 5725.0  -  5825.0 0.25  

This device must be professionally installed.Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


36: Certain antennas used with this equipment require a minimum cable length, or have output power limitations as documented in the application.
CC: This device is certified pursuant to two different Part 15 rules sections.
CE: This device has shown compliance with the conducted emissions limits in 15.107, 15.207, or 18.307 adopted under FCC 02-157 (ET Docket 98-80). The device may be marketed after July 11, 2005, and is not affected by the 15.37(j) or 18.123 transition provisions.

TCB Grant - Application iTnLGR3hxuQfwRIMR8Uj/Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CTC advanced GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 03/18/2005

Application Dated: 03/18/2005
Siemens AG
Type Test Center Karlsruhe
Oestliche Rheinbrueckenstr. 50
D-76181 Karlsruhe,
Germany
 
Attention: Christian Funk

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LYHW700-2-V1
Name of Grantee:  Siemens AG
Equipment Class: Digital Transmission System
Notes: 2.4/5 GHz IEEE 802.11a/b/g WLAN Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
36 CC 15C 2412.0  -  2462.0 0.58  

PCII to adds two alternative antennas. This device must be professionally installed. Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

36: Certain antennas used with this equipment require a minimum cable length, or have output power limitations as documented in the application.
CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application iTnLGR3hxuQfwRIMR8Uj/Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Siemens AG
Type Test Center Karlsruhe Oestliche Rheinbrueckenstr. 50
D-76181 Karlsruhe,
Germany
  Date of Grant: 03/18/2005

Application Dated: 03/18/2005
 
Attention: Christian Funk

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LYHW700-2-V1
Name of Grantee:  Siemens AG
Equipment Class: Digital Transmission System
Notes: 2.4/5 GHz IEEE 802.11a/b/g WLAN Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
36 CC 15C 2412.0  -  2462.0 0.58  

PCII to adds two alternative antennas. This device must be professionally installed. Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


36: Certain antennas used with this equipment require a minimum cable length, or have output power limitations as documented in the application.
CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application egpDRJiWCqe+tiKjrL7bmA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CTC advanced GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 09/28/2006

Application Dated: 09/28/2006
Siemens AG
Type Test Center Karlsruhe
Oestliche Rheinbrueckenstr. 50
D-76181 Karlsruhe,
Germany
 
Attention: Christian Funk

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LYHW700-2-V1
Name of Grantee:  Siemens AG
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 2.4/5 GHz IEEE 802.11a/b/g WLAN Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
36 CC 15E 5180.0  -  5240.0 0.016  
36 CC 15E 5260.0  -  5320.0 0.045  
36 CC 15E 5745.0  -  5805.0 0.03  

PCII to allow 5.15 – 5.25 GHz operation.

This device must be professionally installed.

Power Output listed is conducted.

The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Operations in the 5.25-5.35GHz band are subject to Section 15.37(l) transition period.


36: Certain antennas used with this equipment require a minimum cable length, or have output power limitations as documented in the application.
CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application egpDRJiWCqe+tiKjrL7bmA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Siemens AG
Type Test Center Karlsruhe Oestliche Rheinbrueckenstr. 50
D-76181 Karlsruhe,
Germany
  Date of Grant: 09/28/2006

Application Dated: 09/28/2006
 
Attention: Christian Funk

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LYHW700-2-V1
Name of Grantee:  Siemens AG
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 2.4/5 GHz IEEE 802.11a/b/g WLAN Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
36 CC 15E 5180.0  -  5240.0 0.016  
36 CC 15E 5260.0  -  5320.0 0.045  
36 CC 15E 5745.0  -  5805.0 0.03  

PCII to allow 5.15 – 5.25 GHz operation.

This device must be professionally installed.

Power Output listed is conducted.

The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Operations in the 5.25-5.35GHz band are subject to Section 15.37(l) transition period.


36: Certain antennas used with this equipment require a minimum cable length, or have output power limitations as documented in the application.
CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application BDzFFB2QYpundbDq7Qs6/g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CTC advanced GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 06/23/2004

Application Dated: 06/23/2004
Siemens AG
Type Test Center Karlsruhe
Oestliche Rheinbrueckenstr. 50
D-76181 Karlsruhe,
Germany
 
Attention: Christian Funk

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LYHW700-2-V1
Name of Grantee:  Siemens AG
Equipment Class: Digital Transmission System
Notes: 2.4/5 GHz IEEE 802.11a/b/g WLAN Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
36 CC CE 15C 2412.0  -  2462.0 0.58  

This device must be professionally installed.Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

36: Certain antennas used with this equipment require a minimum cable length, or have output power limitations as documented in the application.
CC: This device is certified pursuant to two different Part 15 rules sections.
CE: This device has shown compliance with the conducted emissions limits in 15.107, 15.207, or 18.307 adopted under FCC 02-157 (ET Docket 98-80). The device may be marketed after July 11, 2005, and is not affected by the 15.37(j) or 18.123 transition provisions.

EAS Grant - Application BDzFFB2QYpundbDq7Qs6/g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Siemens AG
Type Test Center Karlsruhe Oestliche Rheinbrueckenstr. 50
D-76181 Karlsruhe,
Germany
  Date of Grant: 06/23/2004

Application Dated: 06/23/2004
 
Attention: Christian Funk

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LYHW700-2-V1
Name of Grantee:  Siemens AG
Equipment Class: Digital Transmission System
Notes: 2.4/5 GHz IEEE 802.11a/b/g WLAN Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
36 CC CE 15C 2412.0  -  2462.0 0.58  

This device must be professionally installed.Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


36: Certain antennas used with this equipment require a minimum cable length, or have output power limitations as documented in the application.
CC: This device is certified pursuant to two different Part 15 rules sections.
CE: This device has shown compliance with the conducted emissions limits in 15.107, 15.207, or 18.307 adopted under FCC 02-157 (ET Docket 98-80). The device may be marketed after July 11, 2005, and is not affected by the 15.37(j) or 18.123 transition provisions.

Mail To: