FCC ID M4ZID6200

IDentity 6204 (900 MHz) RFID Reader

by 3M Traffic Safety Systems

Grantee Code: M4Z   Product Code: ID6200
Latest application date: 2012-01-30

FCC ID Device Details

FCC IDM4ZID6200
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeM4Z
Product CodeID6200
Applicant Business3M Traffic Safety Systems 🇺🇸
Related Domains mmm.com nemko.com
Equipment ClassIDentity 6204 (900 MHz) RFID Reader
Test FirmNemko Dallas, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.75-903.25 MHzOriginal Equipment2012-01-30

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2012-01-30PDF 2.1 MB
internal photosInternal Photos2012-01-30PDF 5.6 MB
external photosExternal Photos2012-01-30PDF 1.7 MB
labelID Label/Location Info2012-01-30PDF 119.4 KB
label locationID Label/Location Info2012-01-30PDF 540 KB
test reportTest Report2012-01-30PDF 559.9 KB
agent letterCover Letter(s)2012-01-30PDF 29.1 KB
confidential letterCover Letter(s)2012-01-30PDF 45.7 KB
tune up procedureParts List/Tune Up Info2012-01-30PDF 39.8 KB
MPE calculationRF Exposure Info2012-01-30PDF 19 KB

Application Information

Application IDbl8LzzmkyB1dKd644b+Fkg==
Final Action Date2012-01-30
Application PurposeOriginal Equipment
Applicant FRN0005881040
ModelID6200
Frequency Range902.75-903.25 MHz
Equipment ClassLMS - Part 90 Location & Monitoring Transmitter
Device DescriptionIDentity 6204 (900 MHz) RFID Reader
Responsible PartyRandal D. Roebuck, Manager, RFID Regulatory, RDRoebuck@mmm.com , 512-984-5688
AgentZarah Zarah Zarah, Nemko USA, Zarah.MacIvor@nemko.com , 214-629-5683
Technical ContactRandal Roebuck, Sirit Technologies, Inc., RDRoebuck@federalsignal.com , 972-243-7208
Non-Technical ContactZarah G MacIvor, Nemko USA, Inc., zarah.macivor@nemko.com , 214-629-5683
Test FirmMike Cantwell, Nemko Dallas, Inc., mike.cantwell@nemko.com , 972-436-9600
TCB Emailstuart.beck@nemko.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. The RF output power is adjustable in 0.1 dB steps down to 0.01 watts. This device must be professionally installed. The peak radiated output power at each antenna terminal must not exceed 30 W ERP. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 100 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
bl8LzzmkyB1dKd644b+Fkg==2012-01-30Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
902.75-903.25 MHz31ppm587KK1D90.353
911.2-920.45 MHz31ppm585KK1D90.353
911.7-919.95 MHz21ppm1M03K1D90.353
914.25-915.75 MHz31ppm1M66K1D90.353

Grants

TCB Grant - Application bl8LzzmkyB1dKd644b+Fkg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko Canada Inc.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 01/30/2012

Application Dated: 01/27/2012
3M Traffic Safety Systems
3M Center, Building 225-4
St. Paul, MN 55144
 
Attention: Randal Roebuck , Manager, RFID Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M4ZID6200
Name of Grantee:  3M Traffic Safety Systems
Equipment Class: Part 90 Location & Monitoring Transmitter
Notes: IDentity 6204 (900 MHz) RFID Reader
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.353 902.75  -  903.25 3.0 1.0  PM 587KK1D
90.353 911.2  -  920.45 3.0 1.0  PM 585KK1D
90.353 911.7  -  919.95 2.0 1.0  PM 1M03K1D
90.353 914.25  -  915.75 3.0 1.0  PM 1M66K1D

Power listed is conducted. The RF output power is adjustable in 0.1 dB steps down to 0.01 watts. This device must be professionally installed. The peak radiated output power at each antenna terminal must not exceed 30 W ERP. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 100 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application bl8LzzmkyB1dKd644b+Fkg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

3M Traffic Safety Systems
3M Center, Building 225-4
St. Paul, MN 55144
United States
  Date of Grant: 01/30/2012

Application Dated: 01/27/2012
 
Attention: Randal Roebuck , Manager, RFID Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M4ZID6200
Name of Grantee:  3M Traffic Safety Systems
Equipment Class: Part 90 Location & Monitoring Transmitter
Notes: IDentity 6204 (900 MHz) RFID Reader
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.353 902.75  -  903.25 3.0 1.0  PM 587KK1D
90.353 911.2  -  920.45 3.0 1.0  PM 585KK1D
90.353 911.7  -  919.95 2.0 1.0  PM 1M03K1D
90.353 914.25  -  915.75 3.0 1.0  PM 1M66K1D

Power listed is conducted. The RF output power is adjustable in 0.1 dB steps down to 0.01 watts. This device must be professionally installed. The peak radiated output power at each antenna terminal must not exceed 30 W ERP. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 100 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.