Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2018-01-24
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2017-12-21
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2017-12-21
2402-2480 MHzOriginal Equipment2017-02-07
2402-2480 MHzOriginal Equipment2017-02-07
5180-5240 MHzOriginal Equipment2017-02-07

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2017-08-06PDF 1.8 MB
Users Manual_StatementUsers Manual2017-08-06PDF 54.4 KB
Internal photoInternal Photos2017-12-21PDF 3.6 MB
Internal PhotosInternal Photos2017-08-06PDF 3.5 MB
External photoExternal Photos2017-12-21PDF 436 KB
External PhotosExternal Photos2017-08-06PDF 436 KB
ID LabelID Label/Location Info2017-02-07PDF 558.2 KB
Label locationID Label/Location Info2017-02-07PDF 40.4 KB
Test Setup PhotosTest Setup Photos2018-01-24PDF 2.5 MB
Test setup photoTest Setup Photos2017-12-21PDF 344.5 KB
Test Setup PhotosTest Setup Photos2017-08-06PDF 2 MB
Test Setup Photos RevisedTest Setup Photos2017-08-06PDF 342.6 KB
Test Report_DFSTest Report2018-01-24PDF 688.7 KB
Test Report_NIITest Report2018-01-24PDF 875.5 KB
Test Report_NIITest Report2017-12-21PDF 930.1 KB
Test report_DTSTest Report2017-12-21PDF 813.4 KB
Test ReportTest Report2017-02-07PDF 931 KB
Test Report for BT LETest Report2017-02-07PDF 496.9 KB
Test Report for DFSTest Report2017-02-07PDF 662.4 KB
Test Report for NIITest Report2017-02-07PDF 922 KB
Test Report for WLANTest Report2017-02-07PDF 808.2 KB
Attestation DFS Client DeclarationCover Letter(s)2017-02-07PDF 2.8 MB
Class II Permissive ChangeCover Letter(s)2018-01-24PDF 20.8 KB
ConfidentialityCover Letter(s)2018-01-24PDF 191.5 KB
Declaration of authorizationCover Letter(s)2018-01-24PDF 207.4 KB
Confidentiality Request Long termCover Letter(s)2017-12-21PDF 146 KB
Cover Letter Agent AuthorizationCover Letter(s)2017-12-21PDF 145.7 KB
Cover Letter Description of ChangeCover Letter(s)2017-12-21PDF 20.6 KB
AuthorizationCover Letter(s)2017-02-07PDF 1.3 MB
Confidentiality_LTCCover Letter(s)2017-02-07PDF 1.5 MB
Confidentiality_STCCover Letter(s)2017-02-07PDF 1.4 MB
MPERF Exposure Info2018-01-24PDF 147.2 KB
MPERF Exposure Info2017-12-21PDF 144.4 KB
MPERF Exposure Info2017-02-07PDF 147.4 KB
Block Diagram Metadata onlyBlock DiagramPDF 872.5 KB
Block Diagram_Modular Metadata onlyBlock DiagramPDF 118.5 KB
Schematics Metadata onlySchematicsPDF 1.7 MB
Operational Description Metadata onlyOperational DescriptionPDF 27 KB
Software Operating Description Metadata onlyOperational DescriptionPDF 1 MB
Software Operating Description Metadata onlyOperational DescriptionPDF 2.2 MB
Software Security for UNII Metadata onlyOperational DescriptionPDF 1 MB

Application Information

Application IDmqSxnRH+Kx31QeVgwG/R1A==
Final Action Date2018-01-24
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0008093957
ModelEEDII
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionEagleEye Director II
Responsible PartyYuk Wan, Director, Corporate Technical Compliance, yuk.wan@poly.com , +441753723174
AgentAndrea Andrea Andrea, Bureau Veritas Consumer Products Services (H.K.) L, andrea.hsia@tw.bureauveritas.com , 886-3-318-3232
Technical ContactHank Chung, Bureau Veritas Consumer Products Services, hank.chung@tw.bureauveritas.com , 88633183232
Non-Technical ContactAndrea Hsia, Bureau Veritas Consumer Products Services, andrea.hsia@tw.bureauveritas.com , 88633183232
Test FirmRichard Chen, Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch, richard.chen@bureauveritas.com , +886-(0)3-260-0884
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsC2PC: Frequency band decreases via software (5500MHz to 5700MHz) Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290MHz, 5530MHz and 5775 MHz. The device is DFS operation without radar detection mode.

Applications

Application IDDatePurpose
mqSxnRH+Kx31QeVgwG/R1A==2018-01-24Class II permissive change or modification of presently authorized equipment
d2Hx6KlLEwPbnFjRyLfIEg==2017-12-21Class II permissive change or modification of presently authorized equipment
bQ6lWc3PQhN01xYXC/ws6w==2017-12-21Class II permissive change or modification of presently authorized equipment
vBQGU3c2j826AioLrhsn6g==2017-02-07Original Equipment
lcfDb1Uv3rnopFWKLUZMUA==2017-02-07Original Equipment
aAbjGmCVNgxJq9q8tn1dwA==2017-02-07Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.00315CCC
2402-2480 MHz0.002000015CCC
2412-2462 MHz0.14315CCC
5180-5240 MHz0.06415E38, CC
5260-5320 MHz0.06115E38, CC, ND
5500-5700 MHz0.05515E38, CC, ND
5745-5825 MHz0.03515E38, CC

Grants

TCB Grant - Application vBQGU3c2j826AioLrhsn6g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 02/07/2017

Application Dated: 02/06/2017
Polycom Inc.
6001 America Center Drive
San Jose, CA 95002
 
Attention: Yuk Wan , Director, Corporate Technical Compliance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M72-EEDII
Name of Grantee:  Polycom Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: EagleEye Director II
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.002  

Output power listed is conducted. End-users must be informed of transmitter operating conditions for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application vBQGU3c2j826AioLrhsn6g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Polycom Inc.
6001 America Center Drive
San Jose, CA 95002
United States
  Date of Grant: 02/07/2017

Application Dated: 02/06/2017
 
Attention: Yuk Wan , Director, Corporate Technical Compliance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M72-EEDII
Name of Grantee:  Polycom Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: EagleEye Director II
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.002  

Output power listed is conducted. End-users must be informed of transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application mqSxnRH+Kx31QeVgwG/R1A==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 01/24/2018

Application Dated: 01/24/2018
Polycom Inc.
6001 America Center Drive
San Jose, CA 95002
 
Attention: Yuk Wan , Director, Corporate Technical Compliance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M72-EEDII
Name of Grantee:  Polycom Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: EagleEye Director II
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.064  
38 CC ND 15E 5260.0  -  5320.0 0.061  
38 CC 15E 5745.0  -  5825.0 0.035  

C2PC: Frequency band decreases via software (5500MHz to 5700MHz)

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290MHz, 5530MHz and 5775 MHz. The device is DFS operation without radar detection mode.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application mqSxnRH+Kx31QeVgwG/R1A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Polycom Inc.
6001 America Center Drive
San Jose, CA 95002
United States
  Date of Grant: 01/24/2018

Application Dated: 01/24/2018
 
Attention: Yuk Wan , Director, Corporate Technical Compliance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M72-EEDII
Name of Grantee:  Polycom Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: EagleEye Director II
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.064  
38 CC ND 15E 5260.0  -  5320.0 0.061  
38 CC 15E 5745.0  -  5825.0 0.035  

C2PC: Frequency band decreases via software (5500MHz to 5700MHz)

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290MHz, 5530MHz and 5775 MHz. The device is DFS operation without radar detection mode.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application lcfDb1Uv3rnopFWKLUZMUA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 02/07/2017

Application Dated: 02/06/2017
Polycom Inc.
6001 America Center Drive
San Jose, CA 95002
 
Attention: Yuk Wan , Director, Corporate Technical Compliance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M72-EEDII
Name of Grantee:  Polycom Inc.
Equipment Class: Digital Transmission System
Notes: EagleEye Director II
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.003  
CC 15C 2412.0  -  2462.0 0.143  

Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application lcfDb1Uv3rnopFWKLUZMUA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Polycom Inc.
6001 America Center Drive
San Jose, CA 95002
United States
  Date of Grant: 02/07/2017

Application Dated: 02/06/2017
 
Attention: Yuk Wan , Director, Corporate Technical Compliance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M72-EEDII
Name of Grantee:  Polycom Inc.
Equipment Class: Digital Transmission System
Notes: EagleEye Director II
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.003  
CC 15C 2412.0  -  2462.0 0.143  

Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application d2Hx6KlLEwPbnFjRyLfIEg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/21/2017

Application Dated: 12/20/2017
Polycom Inc.
6001 America Center Drive
San Jose, CA 95002
 
Attention: Yuk Wan , Director, Corporate Technical Compliance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M72-EEDII
Name of Grantee:  Polycom Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: EagleEye Director II
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.064  
38 CC ND 15E 5260.0  -  5320.0 0.061  
38 CC ND 15E 5500.0  -  5700.0 0.055  
38 CC 15E 5745.0  -  5825.0 0.035  

C2PC: reduce 2.4G&5GHz power value through software enabling to its original parent application.

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290MHz, 5530MHz and 5775 MHz. The device is DFS operation without radar detection mode.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application d2Hx6KlLEwPbnFjRyLfIEg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Polycom Inc.
6001 America Center Drive
San Jose, CA 95002
United States
  Date of Grant: 12/21/2017

Application Dated: 12/20/2017
 
Attention: Yuk Wan , Director, Corporate Technical Compliance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M72-EEDII
Name of Grantee:  Polycom Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: EagleEye Director II
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.064  
38 CC ND 15E 5260.0  -  5320.0 0.061  
38 CC ND 15E 5500.0  -  5700.0 0.055  
38 CC 15E 5745.0  -  5825.0 0.035  

C2PC: reduce 2.4G&5GHz power value through software enabling to its original parent application.

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290MHz, 5530MHz and 5775 MHz. The device is DFS operation without radar detection mode.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application bQ6lWc3PQhN01xYXC/ws6w==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/21/2017

Application Dated: 12/20/2017
Polycom Inc.
6001 America Center Drive
San Jose, CA 95002
 
Attention: Yuk Wan , Director, Corporate Technical Compliance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M72-EEDII
Name of Grantee:  Polycom Inc.
Equipment Class: Digital Transmission System
Notes: EagleEye Director II
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.003  
CC 15C 2412.0  -  2462.0 0.143  

C2PC: reduce 2.4G&5GHz power value through software enabling to its original parent application.

Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application bQ6lWc3PQhN01xYXC/ws6w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Polycom Inc.
6001 America Center Drive
San Jose, CA 95002
United States
  Date of Grant: 12/21/2017

Application Dated: 12/20/2017
 
Attention: Yuk Wan , Director, Corporate Technical Compliance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M72-EEDII
Name of Grantee:  Polycom Inc.
Equipment Class: Digital Transmission System
Notes: EagleEye Director II
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.003  
CC 15C 2412.0  -  2462.0 0.143  

C2PC: reduce 2.4G&5GHz power value through software enabling to its original parent application.

Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application aAbjGmCVNgxJq9q8tn1dwA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 02/07/2017

Application Dated: 02/06/2017
Polycom Inc.
6001 America Center Drive
San Jose, CA 95002
 
Attention: Yuk Wan , Director, Corporate Technical Compliance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M72-EEDII
Name of Grantee:  Polycom Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: EagleEye Director II
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.064  
38 CC ND 15E 5260.0  -  5320.0 0.061  
38 CC ND 15E 5500.0  -  5700.0 0.055  
38 CC 15E 5745.0  -  5825.0 0.035  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290MHz, 5530MHz and 5775 MHz. The device is DFS operation without radar detection mode.

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application aAbjGmCVNgxJq9q8tn1dwA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Polycom Inc.
6001 America Center Drive
San Jose, CA 95002
United States
  Date of Grant: 02/07/2017

Application Dated: 02/06/2017
 
Attention: Yuk Wan , Director, Corporate Technical Compliance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M72-EEDII
Name of Grantee:  Polycom Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: EagleEye Director II
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.064  
38 CC ND 15E 5260.0  -  5320.0 0.061  
38 CC ND 15E 5500.0  -  5700.0 0.055  
38 CC 15E 5745.0  -  5825.0 0.035  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290MHz, 5530MHz and 5775 MHz. The device is DFS operation without radar detection mode.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

Mail To: