FCC ID M9HA5SE2

GSM 850 & GSM 1900 MHz MOBILE PHONE

by Sagem Wireless

Grantee Code: M9H   Product Code: A5SE2
Latest application date: 2006-03-31

FCC ID Device Details

FCC IDM9HA5SE2
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeM9H
Product CodeA5SE2
Applicant BusinessSagem Wireless 🇫🇷
Related Domains sagemwireless.com
Equipment ClassGSM 850 & GSM 1900 MHz MOBILE PHONE
Test FirmSGS-CSTC Standards Technical Services Co.,Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2006-03-31

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2006-03-31PDF 2.5 MB
Internal PhotographsInternal Photos2006-03-31PDF 116.5 KB
External PhotographsExternal Photos2006-03-31PDF 116.5 KB
Label InformationID Label/Location Info2006-03-31PDF 468.2 KB
Antenna InformationOperational Description2006-03-31PDF 17.1 KB
Test Setup PhotographsTest Setup Photos2006-03-31PDF 296 KB
SAR Test ReportRF Exposure Info2006-03-31PDF 2.3 MB
Test ReportTest Report2006-03-31PDF 996.2 KB
Test Report IITest Report2006-03-31PDF 1.2 MB
Confidentiality ReuqtCover Letter(s)2006-03-31PDF 119.6 KB
Description of Model DifferencesCover Letter(s)2006-03-31PDF 90 KB
Bill Of MaterialsParts List/Tune Up Info2006-03-31PDF 58.5 KB
Block Diagram Metadata onlyBlock DiagramPDF 39.5 KB
MMI Component Layout Metadata onlySchematicsPDF 1.1 MB
Schematics Metadata onlySchematicsPDF 1.2 MB
Operational Description Metadata onlyOperational DescriptionPDF 28.2 KB

Application Information

Application IDaeDK4SYoyvwMq2so6xgxRg==
Final Action Date2006-03-31
Application PurposeOriginal Equipment
Applicant FRN0006731509
ModelA5SE2
Frequency Range824.2-848.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionGSM 850 & GSM 1900 MHz MOBILE PHONE
Responsible PartyFrancois CHAMBON, GM, FCC.contact@sagemwireless.com , 86-574-2796-0448
Test FirmJune Zhang, SGS-CSTC Standards Technical Services Co.,Ltd., June.Zhang@sgs.com , 8675525328598
TCB Emailtcbinfo@metlabs.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to approved belt-clips, holsters or similar accessories tested for this filing and to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 1.29 W/kg; Body-worn 0.884 W/kg; PCS Band Head: 1.12 W/kg; Body-worn 0.536 W/kg.

Applications

Application IDDatePurpose
aeDK4SYoyvwMq2so6xgxRg==2006-03-31Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz1.6290Hz250KGXW22H
1850.2-1909.8 MHz0.8150Hz253KGXW24E

Grants

TCB Grant - Application aeDK4SYoyvwMq2so6xgxRg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Electrical and Electronic Testing NA, Inc
914 W. Patapsco Avenue
Baltimore, MD 21230-3432
Date of Grant: 03/31/2006

Application Dated: 03/31/2006
Sagem Wireless
2, rue du Petit Albi
B.P. 28250
Cergy-Pontoise Cedex, 95801
France
 
Attention: Francois CHAMBON , GM

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M9HA5SE2
Name of Grantee:  Sagem Wireless
Equipment Class: PCS Licensed Transmitter held to ear
Notes: GSM 850 & GSM 1900 MHz MOBILE PHONE
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.6 290.0  Hz 250KGXW
24E 1850.2  -  1909.8 0.8 150.0  Hz 253KGXW

Power Output is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to approved belt-clips, holsters or similar accessories tested for this filing and to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 1.29 W/kg; Body-worn 0.884 W/kg; PCS Band Head: 1.12 W/kg; Body-worn 0.536 W/kg.

EAS Grant - Application aeDK4SYoyvwMq2so6xgxRg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sagem Wireless
2, rue du Petit Albi B.P. 28250
Cergy-Pontoise Cedex, 95801
France
  Date of Grant: 03/31/2006

Application Dated: 03/31/2006
 
Attention: Francois CHAMBON , GM

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M9HA5SE2
Name of Grantee:  Sagem Wireless
Equipment Class: PCS Licensed Transmitter held to ear
Notes: GSM 850 & GSM 1900 MHz MOBILE PHONE
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.6 290.0  Hz 250KGXW
24E 1850.2  -  1909.8 0.8 150.0  Hz 253KGXW

Power Output is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to approved belt-clips, holsters or similar accessories tested for this filing and to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 1.29 W/kg; Body-worn 0.884 W/kg; PCS Band Head: 1.12 W/kg; Body-worn 0.536 W/kg.



Mail To: