FCC ID M9HA6CAE6P

GSM 850/1900 Mobile Phone

by Sagem Wireless

Grantee Code: M9H   Product Code: A6CAE6P
Latest application date: 2007-03-14

FCC ID Device Details

FCC IDM9HA6CAE6P
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeM9H
Product CodeA6CAE6P
Applicant BusinessSagem Wireless 🇫🇷
Related Domains sagemwireless.com
Equipment ClassGSM 850/1900 Mobile Phone
Test FirmCETECOM ICT Services GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2007-03-14

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2007-03-14PDF 2.5 MB
Internal PhotosInternal Photos2007-03-14PDF 889.4 KB
External PhotosExternal Photos2007-03-14PDF 230 KB
ID Label and LocationID Label/Location Info2007-03-14PDF 69.5 KB
Test Setup PhotosTest Setup Photos2007-03-14PDF 386 KB
Test ReportTest Report2007-03-14PDF 653 KB
Confidentiality RequestCover Letter(s)2007-03-14PDF 98.1 KB
SAR Calibration Data Part 1RF Exposure Info2007-03-14PDF 1.2 MB
SAR Calibration Data Part 2RF Exposure Info2007-03-14PDF 3.3 MB
SAR ReportRF Exposure Info2007-03-14PDF 2.8 MB

Application Information

Application IDCjfOogsA4MLAoHWN3QGRIA==
Final Action Date2007-03-14
Application PurposeOriginal Equipment
Applicant FRN0006731509
ModelA6CAE6P
Frequency Range824.2-848.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionGSM 850/1900 Mobile Phone
Responsible PartyFrancois CHAMBON, GM, FCC.contact@sagemwireless.com , 86-574-2796-0448
Test FirmGerald Schmidt, CETECOM ICT Services GmbH, tcb@cetecom.com , 49-681-598-0
TCB Emailjoachim.seewald@ict.cetecom.de
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22: Head: 1.01 W/kg, Body: 0.44 W/kg. Part 24: Head: 1.05 W/kg, Body: 0.53 W/kg

Applications

Application IDDatePurpose
CjfOogsA4MLAoHWN3QGRIA==2007-03-14Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz1.050.051ppm300KGXW22H
1850.2-1909.2 MHz1.380.035ppm300KGXW24E

Grants

TCB Grant - Application CjfOogsA4MLAoHWN3QGRIA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CETECOM ICT Services GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 03/14/2007

Application Dated: 03/14/2007
Sagem Wireless
2, rue du Petit Albi
B.P. 28250
Cergy-Pontoise Cedex, 95801
France
 
Attention: Francois CHAMBON , GM

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M9HA6CAE6P
Name of Grantee:  Sagem Wireless
Equipment Class: PCS Licensed Transmitter held to ear
Notes: GSM 850/1900 Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.05 0.051  PM 300KGXW
24E 1850.2  -  1909.2 1.38 0.035  PM 300KGXW

Output power listed is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22: Head: 1.01 W/kg, Body: 0.44 W/kg. Part 24: Head: 1.05 W/kg, Body: 0.53 W/kg

EAS Grant - Application CjfOogsA4MLAoHWN3QGRIA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sagem Wireless
2, rue du Petit Albi B.P. 28250
Cergy-Pontoise Cedex, 95801
France
  Date of Grant: 03/14/2007

Application Dated: 03/14/2007
 
Attention: Francois CHAMBON , GM

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  M9HA6CAE6P
Name of Grantee:  Sagem Wireless
Equipment Class: PCS Licensed Transmitter held to ear
Notes: GSM 850/1900 Mobile Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.05 0.051  PM 300KGXW
24E 1850.2  -  1909.2 1.38 0.035  PM 300KGXW

Output power listed is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22: Head: 1.01 W/kg, Body: 0.44 W/kg. Part 24: Head: 1.05 W/kg, Body: 0.53 W/kg