FCC ID MMA904040

40W MOBILE UHF P25

by Midland Radio Corporation

Grantee Code: MMA   Product Code: 904040
Latest application date: 2012-02-21

FCC ID Device Details

FCC IDMMA904040
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeMMA
Product Code904040
Applicant BusinessMidland Radio Corporation 🇺🇸
Related Domains midlandradio.com
Equipment Class40W MOBILE UHF P25
Test FirmTimco Engineering, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
380-406 MHzClass II permissive change or modification of presently authorized equipment2012-02-21
380-406 MHzOriginal Equipment2008-11-12

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2008-11-12PDF 923.7 KB
Internal PhotosInternal Photos2008-11-12PDF 2.7 MB
External PhotosExternal Photos2008-11-12PDF 2.4 MB
Label InformationID Label/Location Info2008-11-12PDF 691.4 KB
Test Setup PhotosTest Setup Photos2008-11-12PDF 1.3 MB
Test ReportTest Report2012-02-21PDF 134.6 KB
Test ReportTest Report2008-11-12PDF 370.1 KB
Cover LetterCover Letter(s)2012-02-21PDF 55.5 KB
POACover Letter(s)2012-02-21PDF 30.7 KB
Confidential LetterCover Letter(s)2008-11-12PDF 46.6 KB
Justification LetterCover Letter(s)2008-11-12PDF 11.2 KB
Adjustment ProcedureParts List/Tune Up Info2008-11-12PDF 122.5 KB
Alignment ProcedureParts List/Tune Up Info2008-11-12PDF 10 KB
Parts ListParts List/Tune Up Info2008-11-12PDF 25.2 KB
RF ExposureRF Exposure Info2008-11-12PDF 57 KB

Application Information

Application IDQdykyldS+v65JVNGlH4C8A==
Final Action Date2012-02-21
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0005867551
Model904040
Frequency Range380-406 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device Description40W MOBILE UHF P25
Responsible PartyJeff Brame, Director of Engineering, jbrame@midlandradio.com , 816 241-8500
Test FirmSid Sanders, Timco Engineering, Inc., tei@timcoengr.com , 352-472-5500
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45 cm from all persons and must not exceed an antenna gain of 3 dBi. Class II permissive change: This change adds the emission designators for P25 modulation.

Applications

Application IDDatePurpose
QdykyldS+v65JVNGlH4C8A==2012-02-21Class II permissive change or modification of presently authorized equipment
3C4Z5ZnQl7dXYfd2Mdcx2w==2008-11-12Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
380-406 MHz52.5ppm11K2F1E9EF
380-406 MHz402.5ppmNOTE 19EF
380-406 MHz52.5ppmNOTE 19EF
380-406 MHz402.5ppm11K0F3E9EF
380-406 MHz52.5ppm11K0F3E9EF
380-406 MHz402.5ppm11K2F1D9EF
380-406 MHz52.5ppm11K2F1D9EF
380-406 MHz402.5ppm11K2F2D9EF
380-406 MHz52.5ppm11K2F2D9EF
380-406 MHz402.5ppm11K2F1E9EF
406.1-470 MHz402.5ppm16K0F3E9EF
406.1-470 MHz52.5ppm16K0F3E9EF
406.1-470 MHz402.5ppm11K0F3E9EF
406.1-470 MHz52.5ppm11K0F3E9EF
406.1-470 MHz402.5ppm11K2F1D9EF
406.1-470 MHz52.5ppm11K2F1D9EF
406.1-470 MHz402.5ppm11K2F2D9EF
406.1-470 MHz52.5ppm11K2F2D9EF
406.1-470 MHz402.5ppm11K2F1E9EF
406.1-470 MHz52.5ppm11K2F1E9EF
406.1-470 MHz402.5ppmNOTE 19EF
406.1-470 MHz52.5ppmNOTE 19EF

Grants

TCB Grant - Application QdykyldS+v65JVNGlH4C8A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 02/21/2012

Application Dated: 02/21/2012
Midland Radio Corporation
5900 Parretta Drive
Kansas City, MO 64120-2134
 
Attention: Jeff Brame , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MMA904040
Name of Grantee:  Midland Radio Corporation
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: 40W MOBILE UHF P25
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 90 380.0  -  406.0 40.0 2.5  PM NOTE 1
EF 90 380.0  -  406.0 5.0 2.5  PM NOTE 1
EF 90 406.1  -  470.0 40.0 2.5  PM NOTE 1
EF 90 406.1  -  470.0 5.0 2.5  PM NOTE 1

Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45 cm from all persons and must not exceed an antenna gain of 3 dBi.

Class II permissive change: This change adds the emission designators for P25 modulation.


EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

EAS Grant - Application QdykyldS+v65JVNGlH4C8A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Midland Radio Corporation
5900 Parretta Drive
Kansas City, MO 64120-2134
United States
  Date of Grant: 02/21/2012

Application Dated: 02/21/2012
 
Attention: Jeff Brame , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MMA904040
Name of Grantee:  Midland Radio Corporation
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: 40W MOBILE UHF P25
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 90 380.0  -  406.0 40.0 2.5  PM NOTE 1
EF 90 380.0  -  406.0 5.0 2.5  PM NOTE 1
EF 90 406.1  -  470.0 40.0 2.5  PM NOTE 1
EF 90 406.1  -  470.0 5.0 2.5  PM NOTE 1

Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45 cm from all persons and must not exceed an antenna gain of 3 dBi.

Class II permissive change: This change adds the emission designators for P25 modulation.


EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

TCB Grant - Application 3C4Z5ZnQl7dXYfd2Mdcx2w==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 11/12/2008

Application Dated: 11/11/2008
Midland Radio Corporation
5900 Parretta Drive
Kansas City, MO 64120-2134
 
Attention: Jeff Brame , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MMA904040
Name of Grantee:  Midland Radio Corporation
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: 40W Mobile UHF P25
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 90 380.0  -  406.0 40.0 2.5  PM 16K0F3E
EF 90 380.0  -  406.0 5.0 2.5  PM 16K0F3E
EF 90 380.0  -  406.0 40.0 2.5  PM 11K0F3E
EF 90 380.0  -  406.0 5.0 2.5  PM 11K0F3E
EF 90 380.0  -  406.0 40.0 2.5  PM 11K2F1D
EF 90 380.0  -  406.0 5.0 2.5  PM 11K2F1D
EF 90 380.0  -  406.0 40.0 2.5  PM 11K2F2D
EF 90 380.0  -  406.0 5.0 2.5  PM 11K2F2D
EF 90 380.0  -  406.0 40.0 2.5  PM 11K2F1E
EF 90 380.0  -  406.0 5.0 2.5  PM 11K2F1E
EF 90 406.1  -  470.0 40.0 2.5  PM 16K0F3E
EF 90 406.1  -  470.0 5.0 2.5  PM 16K0F3E
EF 90 406.1  -  470.0 40.0 2.5  PM 11K0F3E
EF 90 406.1  -  470.0 5.0 2.5  PM 11K0F3E
EF 90 406.1  -  470.0 40.0 2.5  PM 11K2F1D
EF 90 406.1  -  470.0 5.0 2.5  PM 11K2F1D
EF 90 406.1  -  470.0 40.0 2.5  PM 11K2F2D
EF 90 406.1  -  470.0 5.0 2.5  PM 11K2F2D
EF 90 406.1  -  470.0 40.0 2.5  PM 11K2F1E
EF 90 406.1  -  470.0 5.0 2.5  PM 11K2F1E

Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45 cm from all persons and must not exceed an antenna gain of 3 dBi.

EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

EAS Grant - Application 3C4Z5ZnQl7dXYfd2Mdcx2w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Midland Radio Corporation
5900 Parretta Drive
Kansas City, MO 64120-2134
United States
  Date of Grant: 11/12/2008

Application Dated: 11/11/2008
 
Attention: Jeff Brame , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MMA904040
Name of Grantee:  Midland Radio Corporation
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: 40W Mobile UHF P25
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 90 380.0  -  406.0 40.0 2.5  PM 16K0F3E
EF 90 380.0  -  406.0 5.0 2.5  PM 16K0F3E
EF 90 380.0  -  406.0 40.0 2.5  PM 11K0F3E
EF 90 380.0  -  406.0 5.0 2.5  PM 11K0F3E
EF 90 380.0  -  406.0 40.0 2.5  PM 11K2F1D
EF 90 380.0  -  406.0 5.0 2.5  PM 11K2F1D
EF 90 380.0  -  406.0 40.0 2.5  PM 11K2F2D
EF 90 380.0  -  406.0 5.0 2.5  PM 11K2F2D
EF 90 380.0  -  406.0 40.0 2.5  PM 11K2F1E
EF 90 380.0  -  406.0 5.0 2.5  PM 11K2F1E
EF 90 406.1  -  470.0 40.0 2.5  PM 16K0F3E
EF 90 406.1  -  470.0 5.0 2.5  PM 16K0F3E
EF 90 406.1  -  470.0 40.0 2.5  PM 11K0F3E
EF 90 406.1  -  470.0 5.0 2.5  PM 11K0F3E
EF 90 406.1  -  470.0 40.0 2.5  PM 11K2F1D
EF 90 406.1  -  470.0 5.0 2.5  PM 11K2F1D
EF 90 406.1  -  470.0 40.0 2.5  PM 11K2F2D
EF 90 406.1  -  470.0 5.0 2.5  PM 11K2F2D
EF 90 406.1  -  470.0 40.0 2.5  PM 11K2F1E
EF 90 406.1  -  470.0 5.0 2.5  PM 11K2F1E

Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 45 cm from all persons and must not exceed an antenna gain of 3 dBi.


EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

Mail To: