FCC ID MMAG9

GMRS Transceiver

by Midland Radio Corporation

Grantee Code: MMA   Product Code: G9
Latest application date: 2002-04-23

FCC ID Device Details

FCC IDMMAG9
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeMMA
Product CodeG9
Applicant BusinessMidland Radio Corporation 🇺🇸
Related Domains midlandradio.com erols.com
Equipment ClassGMRS Transceiver
Test FirmCarl T. Jones Corporation

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
462.55-462.725 MHzOriginal Equipment2002-04-23

Exhibits

DocumentTypeAvailableFile
User InstructionsUsers Manual2002-04-23PDF 462.5 KB
Bottom PCBInternal Photos2002-04-23PDF 311.7 KB
Top PCB with ShieldInternal Photos2002-04-23PDF 295.3 KB
Top PCB without ShieldInternal Photos2002-04-23PDF 331.8 KB
External PhotosExternal Photos2002-04-23PDF 790.1 KB
FCC ID Label and LocationID Label/Location Info2002-04-23PDF 50 KB
Block DiagramBlock Diagram2002-04-23PDF 143.3 KB
Schematic DiagramSchematics2002-04-23PDF 534.8 KB
Operational DescriptionOperational Description2002-04-23PDF 19 KB
Test Setup PhotoTest Setup Photos2002-04-23PDF 22.6 KB
Test ReportTest Report2002-04-23PDF 354 KB
Transmitter AlignmentParts List/Tune Up Info2002-04-23PDF 22 KB

Application Information

Application IDu39xmvoc08d8yX9HCKVG7g==
Final Action Date2002-04-23
Application PurposeOriginal Equipment
Applicant FRN0005867551
ModelG9
Frequency Range462.55-462.725 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionGMRS Transceiver
Responsible PartyButch Rittmann, Director of Operations, brittmann@midlandradio.com , 816 241-8500
AgentRowland Rowland Rowland, Hyak Laboratories, Inc., hyak@erols.com , (703) 451-1188
Technical ContactRowland S Johnson, Hyak Laboratories, Inc., hyak@erols.com , (703) 451-1188
Non-Technical ContactGeorgia Hall, Hyak Laboratories, Inc., hyak@erols.com , (703) 451-1188
Test FirmCarl Jones, Carl T. Jones Corporation, ctjones@ctjc.com , 703-569-7704
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower is ERP. The duty-factor is not to exceed 50%. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
u39xmvoc08d8yX9HCKVG7g==2002-04-23Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
462.55-462.725 MHz1.40000000.0005000000%16K0F3E95A

Grants

TCB Grant - Application u39xmvoc08d8yX9HCKVG7g==

This application does not exist.

EAS Grant - Application u39xmvoc08d8yX9HCKVG7g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Midland Radio Corporation
5900 Parretta Drive
Kansas City, MO 64120-2134
United States
  Date of Grant: 04/23/2002

Application Dated: 03/07/2002
 
Attention: Butch Rittmann , Director of Operations

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MMAG9
Name of Grantee:  Midland Radio Corporation
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: GMRS Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
95A 462.55  -  462.725 1.4 0.0005  % 16K0F3E

Power is ERP. The duty-factor is not to exceed 50%. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.



Mail To:
Rowland Johnson`, President
Hyak Laboratories, Inc.
7011 Calamo St., Suite 107
Springfield, VA 22150