FCC ID MQT-AT100R3

Terminal

by XAC Automation Corporation

Grantee Code: MQT   Product Code: AT100R3
Latest application date: 2020-10-23

FCC ID Device Details

FCC IDMQT-AT100R3
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeMQT
Product CodeAT100R3
Applicant BusinessXAC Automation Corporation 🇹🇼
Related Domains xac.com.tw
Equipment ClassTerminal
Test FirmBureau Veritas CPS (H.K.) Ltd., Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2020-10-23
5180-5240 MHzOriginal Equipment2020-10-23
2402-2480 MHzOriginal Equipment2020-10-23
704-711 MHzOriginal Equipment2020-10-23
13.56 MHzOriginal Equipment2020-10-23

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2021-04-22PDF 2.5 MB
Internal PhotosInternal Photos2021-04-22PDF 5 MB
External PhotosExternal Photos2021-04-22PDF 774.9 KB
ID LabelID Label/Location Info2020-10-23PDF 127.1 KB
ID Label LocationID Label/Location Info2020-10-23PDF 57.4 KB
Test Setup Photos_DFSTest Setup Photos2021-04-22PDF 98.9 KB
Test Setup Photos_NIITest Setup Photos2021-04-22PDF 779.1 KB
Test Setup Photos_SARTest Setup Photos2021-04-22PDF 416.9 KB
Test Setup Photos_WWANTest Setup Photos2021-04-22PDF 430.8 KB
Test Report_BLETest Report2020-10-23PDF 990.8 KB
Test Report_DFSTest Report2020-10-23PDF 839.4 KB
Test Report_DSSTest Report2020-10-23PDF 1.4 MB
Test Report_DXXTest Report2020-10-23PDF 1,004.6 KB
Test Report_NIITest Report2020-10-23PDF 2.6 MB
Test Report_Part22Test Report2020-10-23PDF 1.1 MB
Test Report_Part24Test Report2020-10-23PDF 3.4 MB
Test Report_Part27Test Report2020-10-23PDF 4.5 MB
Test Report_WiFiTest Report2020-10-23PDF 1.5 MB
Declaration LetterCover Letter(s)2020-10-23PDF 60.5 KB
Declaration Letter_DFSCover Letter(s)2020-10-23PDF 164.1 KB
LTCR LetterCover Letter(s)2020-10-23PDF 28.4 KB
POACover Letter(s)2020-10-23PDF 28.5 KB
STCR LetterCover Letter(s)2020-10-23PDF 20.6 KB
SAR Report-1RF Exposure Info2020-10-23PDF 2.8 MB
SAR Report-2RF Exposure Info2020-10-23PDF 3.2 MB
Block Diagram Metadata onlyBlock DiagramPDF 514.1 KB
Schematics-1 Metadata onlySchematicsPDF 100.7 KB
Schematics-2 Metadata onlySchematicsPDF 433.8 KB
Operational Description Metadata onlyOperational DescriptionPDF 269.1 KB
Software Security Metadata onlySDR Software/Security InfPDF 92.6 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 69 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 110.2 KB

Application Information

Application IDcBPKMjaCGFR7FNBcci7D2w==
Final Action Date2020-10-23
Application PurposeOriginal Equipment
Applicant FRN0015348428
ModelAT100R3
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionTerminal
Responsible PartyEric Hong, Section Manager, eric_hong@xac.com.tw , 886-3-5772738
Test FirmRichard Chen, Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch, richard.chen@bureauveritas.com , +886-(0)3-260-0884
TCB Emailvina.kerai@nemko.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date04/22/2021
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) and simultaneously transmission exposure conditions are 0.19W/kg and 3.13W/kg, respectively.

Applications

Application IDDatePurpose
cBPKMjaCGFR7FNBcci7D2w==2020-10-23Original Equipment
SzPHN5f7Gj0E+wSpNibxgA==2020-10-23Original Equipment
L1E/qI6wC4IJt7qYM5fsiA==2020-10-23Original Equipment
FeyUY0kDkddx4VdE/Tpl3w==2020-10-23Original Equipment
4+2hAhWFQvytqmX6bbrLfg==2020-10-23Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
13.56 MHz15CCC
704-711 MHz0.1590.02ppm8M98G7D27
704-711 MHz0.1310.02ppm8M96D7W27
826.4-846.6 MHz0.1240.034ppm4M16F9W22H
1720-1745 MHz0.3360.016ppm17M9G7D27
1720-1745 MHz0.2920.016ppm17M9D7W27
1852.4-1907.6 MHz0.2190.011ppm4M17F9W24E
1860-1900 MHz0.240.016ppm17M9G7D24E
1860-1900 MHz0.2070.016ppm17M9D7W24E
2402-2480 MHz0.017000015CCC
2402-2480 MHz0.00215CCC
2412-2462 MHz0.27515CCC
5180-5240 MHz0.05215ECC
5260-5320 MHz0.02315ECC, ND
5500-5720 MHz0.02415ECC, ND
5745-5825 MHz0.0615ECC

Grants

TCB Grant - Application SzPHN5f7Gj0E+wSpNibxgA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 10/23/2020

Application Dated: 10/23/2020
XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX,
SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-AT100R3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.052  
CC ND 15E 5260.0  -  5320.0 0.023  
CC ND 15E 5500.0  -  5720.0 0.024  
CC 15E 5745.0  -  5825.0 0.06  

Output power listed is conducted. This device has 20 MHz and 40MHz bandwidth modes. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) exposure condition is 0.66 W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application SzPHN5f7Gj0E+wSpNibxgA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
  Date of Grant: 10/23/2020

Application Dated: 10/23/2020
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-AT100R3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.052  
CC ND 15E 5260.0  -  5320.0 0.023  
CC ND 15E 5500.0  -  5720.0 0.024  
CC 15E 5745.0  -  5825.0 0.06  

Output power listed is conducted. This device has 20 MHz and 40MHz bandwidth modes. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) exposure condition is 0.66 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application L1E/qI6wC4IJt7qYM5fsiA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 10/23/2020

Application Dated: 10/23/2020
XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX,
SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-AT100R3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Digital Transmission System
Notes: Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.002  
CC 15C 2412.0  -  2462.0 0.275  

Output power listed is conducted. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) exposure condition is 1.37W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application L1E/qI6wC4IJt7qYM5fsiA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
  Date of Grant: 10/23/2020

Application Dated: 10/23/2020
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-AT100R3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Digital Transmission System
Notes: Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.002  
CC 15C 2412.0  -  2462.0 0.275  

Output power listed is conducted. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) exposure condition is 1.37W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application FeyUY0kDkddx4VdE/Tpl3w==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 10/23/2020

Application Dated: 10/23/2020
XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX,
SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-AT100R3
Name of Grantee:  XAC Automation Corporation
Equipment Class: PCS Licensed Transmitter
Notes: Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 826.4  -  846.6 0.124 0.034  PM 4M16F9W
24E 1852.4  -  1907.6 0.219 0.011  PM 4M17F9W
24E 1860.0  -  1900.0 0.24 0.016  PM 17M9G7D
24E 1860.0  -  1900.0 0.207 0.016  PM 17M9D7W
27 1720.0  -  1745.0 0.336 0.016  PM 17M9G7D
27 1720.0  -  1745.0 0.292 0.016  PM 17M9D7W
27 704.0  -  711.0 0.159 0.02  PM 8M98G7D
27 704.0  -  711.0 0.131 0.02  PM 8M96D7W

Output power listed is ERP for below 1GHz, EIRP for above 1GHz. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) and simultaneously transmission exposure conditions are 3.09W/kg and 3.13W/kg, respectively.

This device has 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15MHz and 20 MHz bandwidth modes for LTE Band 2 and Band 4; 1.4 MHz, 3 MHz, 5 MHz, 10 MHz bandwidth modes for LTE Band 12.


EAS Grant - Application FeyUY0kDkddx4VdE/Tpl3w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
  Date of Grant: 10/23/2020

Application Dated: 10/23/2020
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-AT100R3
Name of Grantee:  XAC Automation Corporation
Equipment Class: PCS Licensed Transmitter
Notes: Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 826.4  -  846.6 0.124 0.034  PM 4M16F9W
24E 1852.4  -  1907.6 0.219 0.011  PM 4M17F9W
24E 1860.0  -  1900.0 0.24 0.016  PM 17M9G7D
24E 1860.0  -  1900.0 0.207 0.016  PM 17M9D7W
27 1720.0  -  1745.0 0.336 0.016  PM 17M9G7D
27 1720.0  -  1745.0 0.292 0.016  PM 17M9D7W
27 704.0  -  711.0 0.159 0.02  PM 8M98G7D
27 704.0  -  711.0 0.131 0.02  PM 8M96D7W

Output power listed is ERP for below 1GHz, EIRP for above 1GHz. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) and simultaneously transmission exposure conditions are 3.09W/kg and 3.13W/kg, respectively.

This device has 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15MHz and 20 MHz bandwidth modes for LTE Band 2 and Band 4; 1.4 MHz, 3 MHz, 5 MHz, 10 MHz bandwidth modes for LTE Band 12.



TCB Grant - Application cBPKMjaCGFR7FNBcci7D2w==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 10/23/2020

Application Dated: 10/23/2020
XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX,
SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-AT100R3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.017  

Output power listed is conducted. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) and simultaneously transmission exposure conditions are 0.19W/kg and 3.13W/kg, respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application cBPKMjaCGFR7FNBcci7D2w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
  Date of Grant: 10/23/2020

Application Dated: 10/23/2020
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-AT100R3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.017  

Output power listed is conducted. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) and simultaneously transmission exposure conditions are 0.19W/kg and 3.13W/kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 4+2hAhWFQvytqmX6bbrLfg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 10/23/2020

Application Dated: 10/23/2020
XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX,
SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-AT100R3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 4+2hAhWFQvytqmX6bbrLfg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
  Date of Grant: 10/23/2020

Application Dated: 10/23/2020
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-AT100R3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: