FCC ID MQT-AT100R3
Terminal
by XAC Automation Corporation
Grantee Code: MQT Product Code: AT100R3
Latest application date: 2020-10-23
FCC ID Device Details
| FCC ID | MQT-AT100R3 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | MQT |
| Product Code | AT100R3 |
| Applicant Business | XAC Automation Corporation 🇹🇼 |
| Related Domains | |
| Equipment Class | Terminal |
| Test Firm | Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2020-10-23 |
| 5180-5240 MHz | Original Equipment | 2020-10-23 |
| 2402-2480 MHz | Original Equipment | 2020-10-23 |
| 704-711 MHz | Original Equipment | 2020-10-23 |
| 13.56 MHz | Original Equipment | 2020-10-23 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2021-04-22 | PDF 2.5 MB |
| Internal Photos | Internal Photos | 2021-04-22 | PDF 5 MB |
| External Photos | External Photos | 2021-04-22 | PDF 774.9 KB |
| ID Label | ID Label/Location Info | 2020-10-23 | PDF 127.1 KB |
| ID Label Location | ID Label/Location Info | 2020-10-23 | PDF 57.4 KB |
| Test Setup Photos_DFS | Test Setup Photos | 2021-04-22 | PDF 98.9 KB |
| Test Setup Photos_NII | Test Setup Photos | 2021-04-22 | PDF 779.1 KB |
| Test Setup Photos_SAR | Test Setup Photos | 2021-04-22 | PDF 416.9 KB |
| Test Setup Photos_WWAN | Test Setup Photos | 2021-04-22 | PDF 430.8 KB |
| Test Report_BLE | Test Report | 2020-10-23 | PDF 990.8 KB |
| Test Report_DFS | Test Report | 2020-10-23 | PDF 839.4 KB |
| Test Report_DSS | Test Report | 2020-10-23 | PDF 1.4 MB |
| Test Report_DXX | Test Report | 2020-10-23 | PDF 1,004.6 KB |
| Test Report_NII | Test Report | 2020-10-23 | PDF 2.6 MB |
| Test Report_Part22 | Test Report | 2020-10-23 | PDF 1.1 MB |
| Test Report_Part24 | Test Report | 2020-10-23 | PDF 3.4 MB |
| Test Report_Part27 | Test Report | 2020-10-23 | PDF 4.5 MB |
| Test Report_WiFi | Test Report | 2020-10-23 | PDF 1.5 MB |
| Declaration Letter | Cover Letter(s) | 2020-10-23 | PDF 60.5 KB |
| Declaration Letter_DFS | Cover Letter(s) | 2020-10-23 | PDF 164.1 KB |
| LTCR Letter | Cover Letter(s) | 2020-10-23 | PDF 28.4 KB |
| POA | Cover Letter(s) | 2020-10-23 | PDF 28.5 KB |
| STCR Letter | Cover Letter(s) | 2020-10-23 | PDF 20.6 KB |
| SAR Report-1 | RF Exposure Info | 2020-10-23 | PDF 2.8 MB |
| SAR Report-2 | RF Exposure Info | 2020-10-23 | PDF 3.2 MB |
| Block Diagram Metadata only | Block Diagram | PDF 514.1 KB | |
| Schematics-1 Metadata only | Schematics | PDF 100.7 KB | |
| Schematics-2 Metadata only | Schematics | PDF 433.8 KB | |
| Operational Description Metadata only | Operational Description | PDF 269.1 KB | |
| Software Security Metadata only | SDR Software/Security Inf | PDF 92.6 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 69 KB | |
| Tune up procedure Metadata only | Parts List/Tune Up Info | PDF 110.2 KB |
Application Information
| Application ID | cBPKMjaCGFR7FNBcci7D2w== |
|---|---|
| Final Action Date | 2020-10-23 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0015348428 |
| Model | AT100R3 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | Terminal |
| Responsible Party | Eric Hong, Section Manager, eric_hong@xac.com.tw |
| Test Firm | Richard Chen, Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch, richard.chen@bureauveritas.com |
| TCB Email | vina.kerai@nemko.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 04/22/2021 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) and simultaneously transmission exposure conditions are 0.19W/kg and 3.13W/kg, respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| cBPKMjaCGFR7FNBcci7D2w== | 2020-10-23 | Original Equipment |
| SzPHN5f7Gj0E+wSpNibxgA== | 2020-10-23 | Original Equipment |
| L1E/qI6wC4IJt7qYM5fsiA== | 2020-10-23 | Original Equipment |
| FeyUY0kDkddx4VdE/Tpl3w== | 2020-10-23 | Original Equipment |
| 4+2hAhWFQvytqmX6bbrLfg== | 2020-10-23 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 13.56 MHz | 15C | CC | |||
| 704-711 MHz | 0.159 | 0.02ppm | 8M98G7D | 27 | |
| 704-711 MHz | 0.131 | 0.02ppm | 8M96D7W | 27 | |
| 826.4-846.6 MHz | 0.124 | 0.034ppm | 4M16F9W | 22H | |
| 1720-1745 MHz | 0.336 | 0.016ppm | 17M9G7D | 27 | |
| 1720-1745 MHz | 0.292 | 0.016ppm | 17M9D7W | 27 | |
| 1852.4-1907.6 MHz | 0.219 | 0.011ppm | 4M17F9W | 24E | |
| 1860-1900 MHz | 0.24 | 0.016ppm | 17M9G7D | 24E | |
| 1860-1900 MHz | 0.207 | 0.016ppm | 17M9D7W | 24E | |
| 2402-2480 MHz | 0.0170000 | 15C | CC | ||
| 2402-2480 MHz | 0.002 | 15C | CC | ||
| 2412-2462 MHz | 0.275 | 15C | CC | ||
| 5180-5240 MHz | 0.052 | 15E | CC | ||
| 5260-5320 MHz | 0.023 | 15E | CC, ND | ||
| 5500-5720 MHz | 0.024 | 15E | CC, ND | ||
| 5745-5825 MHz | 0.06 | 15E | CC |
Grants
TCB Grant - Application SzPHN5f7Gj0E+wSpNibxgA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 10/23/2020 Application Dated: 10/23/2020 |
| XAC Automation Corporation |
| 4F., NO.30, INDUSTRY E. RD. IX, |
| SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, |
| HSIN-CHU City, 300 Taiwan |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-AT100R3 |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.052 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.023 | ||
| CC ND | 15E | 5500.0 - 5720.0 | 0.024 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.06 |
| Output power listed is conducted. This device has 20 MHz and 40MHz bandwidth modes. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) exposure condition is 0.66 W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application SzPHN5f7Gj0E+wSpNibxgA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
XAC Automation Corporation 4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, HSIN-CHU City, 300 Taiwan |
Date of Grant: 10/23/2020 Application Dated: 10/23/2020 |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-AT100R3 |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Terminal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.052 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.023 | ||
| CC ND | 15E | 5500.0 - 5720.0 | 0.024 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.06 |
| Output power listed is conducted. This device has 20 MHz and 40MHz bandwidth modes. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) exposure condition is 0.66 W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 10/23/2020 Application Dated: 10/23/2020 |
| XAC Automation Corporation |
| 4F., NO.30, INDUSTRY E. RD. IX, |
| SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, |
| HSIN-CHU City, 300 Taiwan |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-AT100R3 |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.002 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.275 |
| Output power listed is conducted. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) exposure condition is 1.37W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application L1E/qI6wC4IJt7qYM5fsiA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
XAC Automation Corporation 4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, HSIN-CHU City, 300 Taiwan |
Date of Grant: 10/23/2020 Application Dated: 10/23/2020 |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-AT100R3 |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | Terminal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.002 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.275 |
| Output power listed is conducted. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) exposure condition is 1.37W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 10/23/2020 Application Dated: 10/23/2020 |
| XAC Automation Corporation |
| 4F., NO.30, INDUSTRY E. RD. IX, |
| SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, |
| HSIN-CHU City, 300 Taiwan |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-AT100R3 |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 826.4 - 846.6 | 0.124 | 0.034 PM | 4M16F9W | |
| 24E | 1852.4 - 1907.6 | 0.219 | 0.011 PM | 4M17F9W | |
| 24E | 1860.0 - 1900.0 | 0.24 | 0.016 PM | 17M9G7D | |
| 24E | 1860.0 - 1900.0 | 0.207 | 0.016 PM | 17M9D7W | |
| 27 | 1720.0 - 1745.0 | 0.336 | 0.016 PM | 17M9G7D | |
| 27 | 1720.0 - 1745.0 | 0.292 | 0.016 PM | 17M9D7W | |
| 27 | 704.0 - 711.0 | 0.159 | 0.02 PM | 8M98G7D | |
| 27 | 704.0 - 711.0 | 0.131 | 0.02 PM | 8M96D7W |
| Output power listed is ERP for below 1GHz, EIRP for above 1GHz. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) and simultaneously transmission exposure conditions are 3.09W/kg and 3.13W/kg, respectively. This device has 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15MHz and 20 MHz bandwidth modes for LTE Band 2 and Band 4; 1.4 MHz, 3 MHz, 5 MHz, 10 MHz bandwidth modes for LTE Band 12. |
EAS Grant - Application FeyUY0kDkddx4VdE/Tpl3w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
XAC Automation Corporation 4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, HSIN-CHU City, 300 Taiwan |
Date of Grant: 10/23/2020 Application Dated: 10/23/2020 |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-AT100R3 |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Terminal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 826.4 - 846.6 | 0.124 | 0.034 PM | 4M16F9W | |
| 24E | 1852.4 - 1907.6 | 0.219 | 0.011 PM | 4M17F9W | |
| 24E | 1860.0 - 1900.0 | 0.24 | 0.016 PM | 17M9G7D | |
| 24E | 1860.0 - 1900.0 | 0.207 | 0.016 PM | 17M9D7W | |
| 27 | 1720.0 - 1745.0 | 0.336 | 0.016 PM | 17M9G7D | |
| 27 | 1720.0 - 1745.0 | 0.292 | 0.016 PM | 17M9D7W | |
| 27 | 704.0 - 711.0 | 0.159 | 0.02 PM | 8M98G7D | |
| 27 | 704.0 - 711.0 | 0.131 | 0.02 PM | 8M96D7W |
| Output power listed is ERP for below 1GHz, EIRP for above 1GHz. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) and simultaneously transmission exposure conditions are 3.09W/kg and 3.13W/kg, respectively. This device has 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15MHz and 20 MHz bandwidth modes for LTE Band 2 and Band 4; 1.4 MHz, 3 MHz, 5 MHz, 10 MHz bandwidth modes for LTE Band 12. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 10/23/2020 Application Dated: 10/23/2020 |
| XAC Automation Corporation |
| 4F., NO.30, INDUSTRY E. RD. IX, |
| SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, |
| HSIN-CHU City, 300 Taiwan |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-AT100R3 |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.017 |
| Output power listed is conducted. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) and simultaneously transmission exposure conditions are 0.19W/kg and 3.13W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application cBPKMjaCGFR7FNBcci7D2w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
XAC Automation Corporation 4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, HSIN-CHU City, 300 Taiwan |
Date of Grant: 10/23/2020 Application Dated: 10/23/2020 |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-AT100R3 |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Terminal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.017 |
| Output power listed is conducted. End-users must be informed of the extremity operating requirements for satisfying RF exposure compliance. The highest reported SAR for extremity (hand) and simultaneously transmission exposure conditions are 0.19W/kg and 3.13W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 10/23/2020 Application Dated: 10/23/2020 |
| XAC Automation Corporation |
| 4F., NO.30, INDUSTRY E. RD. IX, |
| SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, |
| HSIN-CHU City, 300 Taiwan |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-AT100R3 |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 13.56 - 13.56 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application 4+2hAhWFQvytqmX6bbrLfg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
XAC Automation Corporation 4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, HSIN-CHU City, 300 Taiwan |
Date of Grant: 10/23/2020 Application Dated: 10/23/2020 |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-AT100R3 |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Terminal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 13.56 - 13.56 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |