FCC ID MQT-FD400ETI

Portable Terminal

by XAC Automation Corporation

Grantee Code: MQT   Product Code: FD400ETI
Latest application date: 2010-08-16

FCC ID Device Details

FCC IDMQT-FD400ETI
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeMQT
Product CodeFD400ETI
Applicant BusinessXAC Automation Corporation 🇹🇼
Related Domains xac.com.tw
Equipment ClassPortable Terminal
Test FirmA Test Lab Techno Corp

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2010-08-16

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2010-08-16PDF 78.5 KB
Internal photosInternal Photos2010-08-16PDF 1.3 MB
External photosExternal Photos2010-08-16PDF 480.6 KB
Label format and locationID Label/Location Info2010-08-16PDF 127.3 KB
Test setup photosTest Setup Photos2010-08-16PDF 234.4 KB
Test reportTest Report2010-08-16PDF 698.7 KB
Agenat authorizationCover Letter(s)2010-08-16PDF 64.5 KB
Request for confidentialityCover Letter(s)2010-08-16PDF 28.1 KB
RF exposure InfoRF Exposure Info2010-08-16PDF 78.1 KB

Application Information

Application IDzHSLuRB9rwLz3H9bBMY9ig==
Final Action Date2010-08-16
Application PurposeOriginal Equipment
Applicant FRN0015348428
Model-FD400ETI
Frequency Range824.2-848.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionPortable Terminal
Responsible PartyEric Hong, Section Manager, eric_hong@xac.com.tw , 886-3-5772738
Test FirmCountry Huang, A Test Lab Techno Corp, Country@atl-lab.com.tw , 03-2710188
TCB Emailcertnotice@ccsemc.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is ERP for Part 22 and EIRP for Part 24. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except as documented in the filing. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
zHSLuRB9rwLz3H9bBMY9ig==2010-08-16Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.2-848.8 MHz0.2122.5ppm250KGXW22H28
1850.2-1909.8 MHz0.4082.5ppm247KGXW24E28

Grants

TCB Grant - Application zHSLuRB9rwLz3H9bBMY9ig==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 08/16/2010

Application Dated: 08/16/2010
XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX,
SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-FD400ETI
Name of Grantee:  XAC Automation Corporation
Equipment Class: PCS Licensed Transmitter
Notes: Portable Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
28 22H 824.2  -  848.8 0.212 2.5  PM 250KGXW
28 24E 1850.2  -  1909.8 0.408 2.5  PM 247KGXW

Output power listed is ERP for Part 22 and EIRP for Part 24. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except as documented in the filing. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

28: An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold.

EAS Grant - Application zHSLuRB9rwLz3H9bBMY9ig==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
  Date of Grant: 08/16/2010

Application Dated: 08/16/2010
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-FD400ETI
Name of Grantee:  XAC Automation Corporation
Equipment Class: PCS Licensed Transmitter
Notes: Portable Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
28 22H 824.2  -  848.8 0.212 2.5  PM 250KGXW
28 24E 1850.2  -  1909.8 0.408 2.5  PM 247KGXW

Output power listed is ERP for Part 22 and EIRP for Part 24. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except as documented in the filing. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.


28: An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold.