FCC ID MQT-FD400GT

Portable Terminal

by XAC Automation Corporation

Grantee Code: MQT   Product Code: FD400GT
Latest application date: 2011-09-27

FCC ID Device Details

FCC IDMQT-FD400GT
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeMQT
Product CodeFD400GT
Applicant BusinessXAC Automation Corporation 🇹🇼
Related Domains xac.com.tw tw.bureauveritas.com
Equipment ClassPortable Terminal
Test FirmBureau Veritas CPS (H.K.) Ltd. Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2011-09-27
13.56 MHzOriginal Equipment2011-09-27

Exhibits

DocumentTypeAvailableFile
UserMan_MQT-FD400GT_revUsers Manual2011-09-27PDF 94.3 KB
Int Pho_MQT-FD400GTInternal Photos2011-09-27PDF 397.6 KB
Ext Pho_MQT-FD400GTExternal Photos2011-09-27PDF 512.1 KB
Label Loc_MQT-FD400GTID Label/Location Info2011-09-27PDF 10.7 KB
Label Smpl_MQT-FD400GTID Label/Location Info2011-09-27PDF 199.5 KB
Test Setup-RFID_MQT-FD400GTTest Setup Photos2011-09-27PDF 453.7 KB
Test Setup-WWAN_MQT-FD400GTTest Setup Photos2011-09-27PDF 140.4 KB
Test Rpt-Part 22_MQT-FD400GT_revTest Report2011-09-27PDF 611.1 KB
Test Rpt-Part 24_MQT-FD400GT_revTest Report2011-09-27PDF 611.4 KB
Test Rpt-RFID_MQT-FD400GTTest Report2011-09-27PDF 261.7 KB
Attestation - Frequency Band DeclarationAttestation Statements2011-09-27PDF 24.1 KB
Confidentiality Request_MQT-FD400GTCover Letter(s)2011-09-27PDF 26.8 KB
Coverletter-POA_MQT-FD400GTCover Letter(s)2011-09-27PDF 25.2 KB
RF Exposure Info_MQT-FD400GTRF Exposure Info2011-09-27PDF 77.6 KB

Application Information

Application IDqT5zXpc44ZOn69SnQMOCnw==
Final Action Date2011-09-27
Application PurposeOriginal Equipment
Applicant FRN0015348428
Model-FD400GT
Frequency Range824.2-848.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionPortable Terminal
Responsible PartyEric Hong, Section Manager, eric_hong@xac.com.tw , 886-3-5772738
Technical ContactHank Chung, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, hank.chung@tw.bureauveritas.com , 886-3-593-5343
Non-Technical ContactWendy Liao, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, wendy.liao@tw.bureauveritas.com , 886-3-3183232
Test FirmRichard Chen, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, richard.chen@tw.bureauveritas.com , 886-3-3183232
TCB Emailcertification@curtis-straus.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is ERP for Part 22 and EIRP for Part 24. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End -users must be provided with specific information required to satisfy RF exposure compliance.

Applications

Application IDDatePurpose
qT5zXpc44ZOn69SnQMOCnw==2011-09-27Original Equipment
pu214N55CEnMQMf5FIKZ+A==2011-09-27Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
13.56 MHz15C28
824.2-848.8 MHz1.2592.5ppm248KG7W22H28
824.2-848.8 MHz1.232.5ppm248KG7W22H28
826.4-846.6 MHz0.1292.5ppm4M20F9W22H28
1850.2-1909.8 MHz1.2882.5ppm252KG7W24E28
1850.2-1909.8 MHz1.2592.5ppm248KG7W24E28
1852.4-1907.6 MHz0.2752.5ppm4M22F9W24E28

Grants

TCB Grant - Application qT5zXpc44ZOn69SnQMOCnw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Curtis-Straus LLC
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 09/27/2011

Application Dated: 09/27/2011
XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX,
SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-FD400GT
Name of Grantee:  XAC Automation Corporation
Equipment Class: PCS Licensed Transmitter
Notes: Portable Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
28 22H 824.2  -  848.8 1.259 2.5  PM 248KG7W
28 22H 824.2  -  848.8 1.23 2.5  PM 248KG7W
28 22H 826.4  -  846.6 0.129 2.5  PM 4M20F9W
28 24E 1850.2  -  1909.8 1.288 2.5  PM 252KG7W
28 24E 1850.2  -  1909.8 1.259 2.5  PM 248KG7W
28 24E 1852.4  -  1907.6 0.275 2.5  PM 4M22F9W

Output power is ERP for Part 22 and EIRP for Part 24. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End -users must be provided with specific information required to satisfy RF exposure compliance.

28: An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold.

EAS Grant - Application qT5zXpc44ZOn69SnQMOCnw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
  Date of Grant: 09/27/2011

Application Dated: 09/27/2011
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-FD400GT
Name of Grantee:  XAC Automation Corporation
Equipment Class: PCS Licensed Transmitter
Notes: Portable Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
28 22H 824.2  -  848.8 1.259 2.5  PM 248KG7W
28 22H 824.2  -  848.8 1.23 2.5  PM 248KG7W
28 22H 826.4  -  846.6 0.129 2.5  PM 4M20F9W
28 24E 1850.2  -  1909.8 1.288 2.5  PM 252KG7W
28 24E 1850.2  -  1909.8 1.259 2.5  PM 248KG7W
28 24E 1852.4  -  1907.6 0.275 2.5  PM 4M22F9W

Output power is ERP for Part 22 and EIRP for Part 24. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End -users must be provided with specific information required to satisfy RF exposure compliance.


28: An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold.

TCB Grant - Application pu214N55CEnMQMf5FIKZ+A==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Curtis-Straus LLC
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 09/27/2011

Application Dated: 09/27/2011
XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX,
SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-FD400GT
Name of Grantee:  XAC Automation Corporation
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Portable Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
28 15C 13.56  -  13.56  


28: An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold.

EAS Grant - Application pu214N55CEnMQMf5FIKZ+A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
  Date of Grant: 09/27/2011

Application Dated: 09/27/2011
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-FD400GT
Name of Grantee:  XAC Automation Corporation
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Portable Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
28 15C 13.56  -  13.56  


28: An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold.

Mail To: