Equipment ClassTerminal
Test FirmBureau Veritas CPS (H.K.) Ltd., Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2016-11-23
13.56 MHzOriginal Equipment2016-11-23
2402-2480 MHzOriginal Equipment2016-11-23
5180-5240 MHzOriginal Equipment2016-11-23

Exhibits

DocumentTypeAvailableFile
User Manual Metadata onlyUsers Manual2016-11-23PDF 761.1 KB
User Manual revUsers Manual2016-11-23PDF 5.8 MB
User Manual_rev.pdfUsers Manual2016-11-23PDF 764.2 KB
Internal Photos rev 2Internal Photos2016-11-23PDF 1.6 MB
External PhotosExternal Photos2016-11-23PDF 199.1 KB
Attestation - Label Location Declaration revAttestation Statements2016-11-23PDF 31.7 KB
ID Label Sample and Location InformationID Label/Location Info2016-11-23PDF 88.5 KB
Test Setup PhotoTest Setup Photos2016-11-23PDF 212.2 KB
Test Setup Photo (DFS) revTest Setup Photos2016-11-23PDF 117.1 KB
Test Setup Photo (RFID)Test Setup Photos2016-11-23PDF 105.8 KB
Test Report (BT-EDR)Test Report2016-11-23PDF 920.6 KB
Test Report (BT-LE)Test Report2016-11-23PDF 590.1 KB
Test Report (DFS)Test Report2016-11-23PDF 848.7 KB
Test Report (DTS) revTest Report2016-11-23PDF 1.1 MB
Test Report (NII)Test Report2016-11-23PDF 1.5 MB
Test Report (RFID)Test Report2016-11-23PDF 493 KB
Attestation - Channel and Mode DeclarationAttestation Statements2016-11-23PDF 74.1 KB
Attestation - DFS DeclarationAttestation Statements2016-11-23PDF 38.9 KB
Cover Letter - Agent AuthorizationCover Letter(s)2016-11-23PDF 15.5 KB
Cover Letter - Confidentiality Request - Long TermCover Letter(s)2016-11-23PDF 13.9 KB
RF Exposure Information (MPE)RF Exposure Info2016-11-23PDF 243.4 KB
Block Diagram (ACM) Metadata onlyBlock DiagramPDF 42 KB
Block Diagram (System) Metadata onlyBlock DiagramPDF 60.1 KB
Schematic (ACM) Metadata onlySchematicsPDF 2 MB
Schematics (BATTERY BD) Metadata onlySchematicsPDF 1.7 MB
Schematics (KEYPAD FPC BD) Metadata onlySchematicsPDF 928.1 KB
Schematics (MB(PAYMENT)) Metadata onlySchematicsPDF 1.2 MB
Schematics (MSR LED_PB BD) Metadata onlySchematicsPDF 916.6 KB
Operational Description rev Metadata onlyOperational DescriptionPDF 52.2 KB
Software Operational Description Metadata onlyOperational DescriptionPDF 90.2 KB

Application Information

Application IDojy4mD0aIKSVGKv/48gVmQ==
Final Action Date2016-11-23
Application PurposeOriginal Equipment
Applicant FRN0015348428
ModelPRESTOA3
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionTerminal
Responsible PartyEric Hong, Section Manager, eric_hong@xac.com.tw , 886-3-5772738
Test FirmRichard Chen, Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch, richard.chen@bureauveritas.com , +886-(0)3-260-0884
TCB Emailtcb@us.bureauveritas.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is the conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines.

Applications

Application IDDatePurpose
ojy4mD0aIKSVGKv/48gVmQ==2016-11-23Original Equipment
BwMekpxAWXi+kphRufGYkQ==2016-11-23Original Equipment
4cMPLs+hrvNj67GG3p8UOw==2016-11-23Original Equipment
3kJu5oIPNedODrF0acLZkg==2016-11-23Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
13.56 MHz15CCC
2402-2480 MHz0.016000015CCC
2402-2480 MHz0.001515CCC
2412-2462 MHz0.11615CCC
5180-5240 MHz0.01515E38, CC
5260-5320 MHz0.0215E38, CC
5500-5700 MHz0.01915E38, CC
5745-5825 MHz0.02115E38, CC

Grants

TCB Grant - Application ojy4mD0aIKSVGKv/48gVmQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 11/23/2016

Application Dated: 11/22/2016
XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX,
SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-PRESTOA3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.016  

Power listed is the conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application ojy4mD0aIKSVGKv/48gVmQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
  Date of Grant: 11/23/2016

Application Dated: 11/22/2016
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-PRESTOA3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.016  

Power listed is the conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application BwMekpxAWXi+kphRufGYkQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 11/23/2016

Application Dated: 11/22/2016
XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX,
SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-PRESTOA3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  

End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application BwMekpxAWXi+kphRufGYkQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
  Date of Grant: 11/23/2016

Application Dated: 11/22/2016
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-PRESTOA3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  

End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 4cMPLs+hrvNj67GG3p8UOw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 11/23/2016

Application Dated: 11/22/2016
XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX,
SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-PRESTOA3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Digital Transmission System
Notes: Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.116  
CC 15C 2402.0  -  2480.0 0.0015  

Power listed is the conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines. This device has 20 MHz and 40 MHz bandwidth modes

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 4cMPLs+hrvNj67GG3p8UOw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
  Date of Grant: 11/23/2016

Application Dated: 11/22/2016
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-PRESTOA3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Digital Transmission System
Notes: Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.116  
CC 15C 2402.0  -  2480.0 0.0015  

Power listed is the conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines. This device has 20 MHz and 40 MHz bandwidth modes


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 3kJu5oIPNedODrF0acLZkg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 11/23/2016

Application Dated: 11/22/2016
XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX,
SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-PRESTOA3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.015  
38 CC 15E 5260.0  -  5320.0 0.02  
38 CC 15E 5500.0  -  5700.0 0.019  
38 CC 15E 5745.0  -  5825.0 0.021  

Power listed is the conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines. This device has 20 MHz and 40 MHz bandwidth modes

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 3kJu5oIPNedODrF0acLZkg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

XAC Automation Corporation
4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU,
HSIN-CHU City, 300
Taiwan
  Date of Grant: 11/23/2016

Application Dated: 11/22/2016
 
Attention: Eric Hong , Section Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  MQT-PRESTOA3
Name of Grantee:  XAC Automation Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.015  
38 CC 15E 5260.0  -  5320.0 0.02  
38 CC 15E 5500.0  -  5700.0 0.019  
38 CC 15E 5745.0  -  5825.0 0.021  

Power listed is the conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines. This device has 20 MHz and 40 MHz bandwidth modes


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.