FCC ID MQT-XAPT103PUW
Terminal
by XAC Automation Corporation
Grantee Code: MQT Product Code: XAPT103PUW
Latest application date: 2013-11-07
FCC ID Device Details
| FCC ID | MQT-XAPT103PUW |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | MQT |
| Product Code | XAPT103PUW |
| Applicant Business | XAC Automation Corporation 🇹🇼 |
| Related Domains | |
| Equipment Class | Terminal |
| Test Firm | Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.2-848.8 MHz | Original Equipment | 2013-11-07 |
| 2412-2462 MHz | Original Equipment | 2013-11-07 |
| 13.56 MHz | Original Equipment | 2013-11-07 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Manual.pdf | Users Manual | 2013-11-07 | PDF 210.9 KB |
| Internal Photos.pdf | Internal Photos | 2013-11-07 | PDF 5.1 MB |
| External Photos.pdf | External Photos | 2013-11-07 | PDF 1.2 MB |
| Label and Location.pdf | ID Label/Location Info | 2013-11-07 | PDF 133.7 KB |
| Test Setup Photos (Parts 22 and 24).pdf | Test Setup Photos | 2013-11-07 | PDF 89.9 KB |
| Test Setup Photos (WLAN and RFID).pdf | Test Setup Photos | 2013-11-07 | PDF 157.5 KB |
| Test Report (Part 22).pdf | Test Report | 2013-11-07 | PDF 587.7 KB |
| Test Report (Part 24).pdf | Test Report | 2013-11-07 | PDF 837.1 KB |
| Test Report (RFID).pdf | Test Report | 2013-11-07 | PDF 430.7 KB |
| Test Report (WLAN).pdf | Test Report | 2013-11-07 | PDF 1.1 MB |
| Attestation (Cellular Declaration).pdf | Attestation Statements | 2013-11-07 | PDF 154.1 KB |
| Attestation (Channel and Mode Declaration).pdf | Attestation Statements | 2013-11-07 | PDF 124.3 KB |
| Confidentiality Request.pdf | Cover Letter(s) | 2013-11-07 | PDF 163.6 KB |
| Cover Letter (Agent Authorization).pdf | Cover Letter(s) | 2013-11-07 | PDF 152.6 KB |
| RF Exposure Info.pdf | RF Exposure Info | 2013-11-07 | PDF 352.6 KB |
Application Information
| Application ID | giSt4XohS910SHKJk3cBoQ== |
|---|---|
| Final Action Date | 2013-11-07 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0015348428 |
| Model | -XAPT103PUW |
| Frequency Range | 824.2-848.8 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Terminal |
| Responsible Party | Eric Hong, Section Manager, eric_hong@xac.com.tw |
| Test Firm | Richard Chen, Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch, richard.chen@tw.bureauveritas.com |
| TCB Email | certification@curtis-straus.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power is ERP for Part 22 and EIRP for Part 24. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users and installers must be provided with operating and installation instructions to ensure RF exposure compliance requirements. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| giSt4XohS910SHKJk3cBoQ== | 2013-11-07 | Original Equipment |
| RsVQKhLYC2/baRtoZa7pYA== | 2013-11-07 | Original Equipment |
| 6f1v8Tny9b+7xLE/ipg22g== | 2013-11-07 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 13.56 MHz | 15C | 28, CC | |||
| 824.2-848.8 MHz | 1.585 | 2.5ppm | 246KG7W | 22H | 28 |
| 824.2-848.8 MHz | 0.891 | 2.5ppm | 246KG7W | 22H | 28 |
| 826.4-846.6 MHz | 0.215 | 2.5ppm | 4M08F9W | 22H | 28 |
| 1850.2-1909.8 MHz | 1.549 | 2.5ppm | 246KG7W | 24E | 28 |
| 1850.2-1909.8 MHz | 0.708 | 2.5ppm | 248KG7W | 24E | 28 |
| 1852.4-1907.6 MHz | 0.355 | 2.5ppm | 4M08F9W | 24E | 28 |
| 2412-2462 MHz | 0.1180000 | 15C | 28, CC |
Grants
TCB Grant - Application RsVQKhLYC2/baRtoZa7pYA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Curtis-Straus LLC One Distribution Center Circle Suite #1 Littleton, MA 01460 |
Date of Grant: 11/07/2013 Application Dated: 11/07/2013 |
| XAC Automation Corporation |
| 4F., NO.30, INDUSTRY E. RD. IX, |
| SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, |
| HSIN-CHU City, 300 Taiwan |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-XAPT103PUW |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 28 CC | 15C | 2412.0 - 2462.0 | 0.118 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users and installers must be provided with operating and installation instructions to ensure RF exposure compliance requirements. |
| 28: | An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application RsVQKhLYC2/baRtoZa7pYA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
XAC Automation Corporation 4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, HSIN-CHU City, 300 Taiwan |
Date of Grant: 11/07/2013 Application Dated: 11/07/2013 |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-XAPT103PUW |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | Terminal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 28 CC | 15C | 2412.0 - 2462.0 | 0.118 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users and installers must be provided with operating and installation instructions to ensure RF exposure compliance requirements. |
| 28: | An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Curtis-Straus LLC One Distribution Center Circle Suite #1 Littleton, MA 01460 |
Date of Grant: 11/07/2013 Application Dated: 11/07/2013 |
| XAC Automation Corporation |
| 4F., NO.30, INDUSTRY E. RD. IX, |
| SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, |
| HSIN-CHU City, 300 Taiwan |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-XAPT103PUW |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 28 | 22H | 824.2 - 848.8 | 1.585 | 2.5 PM | 246KG7W |
| 28 | 22H | 824.2 - 848.8 | 0.891 | 2.5 PM | 246KG7W |
| 28 | 22H | 826.4 - 846.6 | 0.215 | 2.5 PM | 4M08F9W |
| 28 | 24E | 1850.2 - 1909.8 | 1.549 | 2.5 PM | 246KG7W |
| 28 | 24E | 1850.2 - 1909.8 | 0.708 | 2.5 PM | 248KG7W |
| 28 | 24E | 1852.4 - 1907.6 | 0.355 | 2.5 PM | 4M08F9W |
| Output power is ERP for Part 22 and EIRP for Part 24. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users and installers must be provided with operating and installation instructions to ensure RF exposure compliance requirements. |
| 28: | An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold. |
EAS Grant - Application giSt4XohS910SHKJk3cBoQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
XAC Automation Corporation 4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, HSIN-CHU City, 300 Taiwan |
Date of Grant: 11/07/2013 Application Dated: 11/07/2013 |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-XAPT103PUW |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Terminal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 28 | 22H | 824.2 - 848.8 | 1.585 | 2.5 PM | 246KG7W |
| 28 | 22H | 824.2 - 848.8 | 0.891 | 2.5 PM | 246KG7W |
| 28 | 22H | 826.4 - 846.6 | 0.215 | 2.5 PM | 4M08F9W |
| 28 | 24E | 1850.2 - 1909.8 | 1.549 | 2.5 PM | 246KG7W |
| 28 | 24E | 1850.2 - 1909.8 | 0.708 | 2.5 PM | 248KG7W |
| 28 | 24E | 1852.4 - 1907.6 | 0.355 | 2.5 PM | 4M08F9W |
| Output power is ERP for Part 22 and EIRP for Part 24. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users and installers must be provided with operating and installation instructions to ensure RF exposure compliance requirements. |
| 28: | An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Curtis-Straus LLC One Distribution Center Circle Suite #1 Littleton, MA 01460 |
Date of Grant: 11/07/2013 Application Dated: 11/07/2013 |
| XAC Automation Corporation |
| 4F., NO.30, INDUSTRY E. RD. IX, |
| SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, |
| HSIN-CHU City, 300 Taiwan |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-XAPT103PUW |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 28 CC | 15C | 13.56 - 13.56 |
| 28: | An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application 6f1v8Tny9b+7xLE/ipg22g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
XAC Automation Corporation 4F., NO.30, INDUSTRY E. RD. IX, SCIENCE-BASED INDUSTRIAL PARK, HSIN-CHU, HSIN-CHU City, 300 Taiwan |
Date of Grant: 11/07/2013 Application Dated: 11/07/2013 |
| Attention: Eric Hong , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | MQT-XAPT103PUW |
| Name of Grantee: | XAC Automation Corporation |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Terminal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 28 CC | 15C | 13.56 - 13.56 |
| 28: | An AC adapter incorporating a ferrite core at the connector end of its DC line must be provided with every unit sold. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |